Acclaim Lighting 2490 Rules for Open Fire Viewing, Clear the Ash Frequently

Page 21

Rules for Open Fire Viewing

WARNING: For safety and greatest effi- ciency, operate your stove only with all doors/griddles fully closed. The test standard for your stove when it is oper- ated in this mode is UL 1482.

Your stove may be used as a fireplace with the front door open or removed only when the spark screen is placed correctly in the opening to protect against the possibility of sparks and em- bers leaving your stove. The test stan- dard for your stove when it is operated in this mode is UL 737.

Use only the Resolute Acclaim spark screen, part #0133, with your Acclaim .

Resolute Acclaim spark screens are available from your Vermont Castings’ Authorized Dealer.

The damper must be open as well whenever you oper- ate the Resolute Acclaim in the open-fire mode. This will prevent smoke and combustion gases from entering the room.

The spark screen fits inside the arch of the inner stove front and is held in place by a top bail and two side clips. (Fig. 32) To insert the screen, place the top bail between the inner front and the air manifold. Push with an even pressure on the sides until the clips snap into place.

The front door may be left on or taken off. To remove it, open it and retract the spring-loaded upper hinge pin. Tilt the door slightly and lift it off the lower hinge pin.

Top Bail

Side Clip

ST616

Fig. 32 Angle the screen to seat the top first, then push the bottom straight in until the clips snap into place.

Resolute® Acclaim Woodburning Stove

Clear the Ash Frequently

The slanted grate is designed to shape the charcoal bed to promote high temperatures near the entrance to the secondary combustion chamber. The grates must be kept free of heavy ash accumulation. Clear ash manually every six to eight hours of operation or before you reload.

To clear the ash, “hoe” the ash and charcoal forward with a stove shovel or similar fireplace tool so they drop through the grate. CAUTION: Do not put any tool up into the secondary combustion chamber or you will risk damaging the refractory package.

Remove and Store Ash Safely

Check the ash pan before reloading the stove. If the ash is close to the top, empty the pan. Before replacing the ash pan, clear away any ash that has spilled over the sides and back of the pan.

When burning wood, empty the

 

ash drawer regularly, typically

 

every one to three days. The

 

frequency will vary de-

 

pending on how hot you

 

run your stove: the

 

hotter the fire, the more

ST438

wood you burn, and the

 

faster ash will accumulate.

 

The ash pan is located in the ash

drop chamber with a handle attached to the front and one to the rear. Always use stove gloves when han- dling the ash pan. Keep it level, and carry it outside for disposal. Empty the ash into your ash disposal con- tainer. When you are finished, slide the pan back into the stove.

Ash may contain hot coals and must be treated with extreme care. It should be removed frequently and placed outdoors in a metal container with a tight-fitting lid. The closed container of ash should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ash is disposed of by burial in soil or otherwise locally dispersed, it should be retained in the closed container until all cinders have thoroughly cooled. Wood ash may be used as a garden fertilizer.

CAUTION: Never use a vacuum cleaner to remove ash from the stove; always re- move and dispose of the ashes properly.

2000893

21

Image 21
Contents Resolute Acclaim Table of Contents AccessoriesIntroduction Resolute Acclaim Model SpecificationsInstallation What Kind of Chimney to UseMasonry Chimneys Double-wall Chimney Connectors Chimney Connector GuidelinesPrefabricated Chimneys Chimney SizeSingle-wall Chimney Connectors Securing the Single-wall Connector To a Masonry ChimneyFreestanding Installations Above a Fireplace Through a FireplaceWall Pass-Throughs An approved wall pass-through for the United States Floor Protection Floor Protection for Fireplace InstallationSafe Ways to Reduce Clearances Keep the Stove a Safe Distance From Surrounding MaterialsWall Shields Reversing the Flue Collar6mm Fireplace InstallationsParallel Installation Corner Stove Clearance Resolute Acclaim Clearance ChartChimney Connector Clearance Front Clearance To CombustiblesTop Exit, No Heat Shields Stove Installed Stove in Corner Parallel to WallMinimum Wall Shield Requirements for Common Installations Corner Parallel Installations Construction Requirements Alcove InstallationsOperation Install Stove LegsUnpack the Stove Two Controls Operate the StoveRemovable Andirons For Greater Front-Loading Convenience Use the Air Control Settings That Work Best for YouTwo Rules For Success Burn Only High-Quality FuelHow to Build and Sustain a Wood Fire Primary Air SettingsAir Setting Air Control Position Starting and Maintaining a Wood FireSurface Thermometer is a Guide to Performance Reloading and Reviving a Wood FireRules for Open Fire Viewing Clear the Ash FrequentlyRemove and Store Ash Safely Draft Management Creosote Draft TestingFuel Back-puffingCleaning the Glass MaintenanceClean the Exhaust Channels Care of the Cast Iron SurfaceAdjust the Damper as Needed Adjust the DoorRepair Missing Cement in Seams Avoid Damaging the GlassHow to Replace Gaskets Replace Broken Glass ImmediatelyResolute Acclaim Gaskets on Moving Parts Replacing the Door Gaskets Gaskets on Resolute Acclaim Stationary PartsReplacing the Griddle Gasket Replace Broken FirebricksYearly Spring Cleaning Resolute Acclaim Maintenance ScheduleDaily Two MonthsItem Description Part Number Resolute Acclaim Woodburning StoveAshlip Door Leg Resolute Acclaim Woodburning StoveWarranty Mhsc

2490 specifications

Acclaim Lighting has made a significant impact in the world of architectural and entertainment lighting with innovative solutions that cater to a wide array of applications. One of their standout products is the Acclaim Lighting 2490, a lighting fixture that exemplifies cutting-edge technology and high performance.

The Acclaim Lighting 2490 is primarily designed for use in both indoor and outdoor settings. Its robust construction ensures durability against various weather conditions, making it an ideal choice for architectural lighting, theatrical productions, and even large-scale events. One of the standout features of the 2490 is its high lumen output, allowing it to provide bright, effective illumination in any scenario.

Equipped with advanced LED technology, the 2490 offers exceptional energy efficiency without compromising brightness. The fixture utilizes high-quality LEDs that not only extend the lifespan of the unit but also minimize heat generation, making it a sustainable choice for long-term use. This energy-efficient operation translates to lower energy costs and reduced environmental impact.

The Acclaim Lighting 2490 boasts versatile color rendering, with RGBW capabilities that allow users to create a wide palette of colors. This feature is particularly beneficial for event lighting and architectural applications where mood and aesthetics play a crucial role. Additionally, the fixture supports DMX control, making it easy to integrate into existing lighting setups and enabling synchronized light shows or dynamic lighting transitions.

Another noteworthy characteristic of the 2490 is its adjustable beam angle. This adaptability provides users with the flexibility to focus light where it's needed most, whether for highlighting architectural features or creating immersive environments for theatrical performances.

Built with user-friendliness in mind, the Acclaim Lighting 2490 includes options for easy mounting and installation. Its lightweight design coupled with intuitive controls ensures that both professional lighting technicians and newcomers can operate it with ease.

Overall, the Acclaim Lighting 2490 stands as a testament to the brand's commitment to quality and innovation in lighting technology. With its combination of efficiency, versatility, and durability, it offers a comprehensive solution for a wide array of lighting needs, making it a preferred choice among lighting designers and professionals alike.