Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Open- ings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement. In the event of a chimney fire, flames and smoke may be forced out of these unused thimbles.

The chimney should be thoroughly cleaned before use.

A newly-built masonry chimney must conform to the standards of your local building code or, in the absence of a local code, to a recognized national code. Masonry chimneys must be lined, either with code-approved ma- sonry or precast refractory tiles, stainless steel pipe, or a code-approved, “poured-in-place” liner. The chim- ney’s clean-out door must seal tightly to help ensure a good draft.

Prefabricated Chimneys

A prefabricated metal chimney must be one tested and listed for use with solid-fuel burning appliances to the High-Temperature (H.T.) Chimney Standard UL-103- 1985 (2100°F.) for the United States, and High Temper- ature (650°C) Standard ULC S-629 for Canada.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

Chimney Size

A Resolute Acclaim is approved for venting into a masonry chimney with a flue size of 8” x 8” (203 x 203 mm), and into a round flue size of 8” (203 mm) or 6” (152 mm).

It may be vented into larger chimneys as well. How- ever, chimneys with liners larger than 8” x 12” (203 x 305 mm) may experience rapid cooling of smoke and reduction in draft, especially if they are located out- side the home. These large chimneys may need to be insulated or to have their flues relined for proper stove performance.

Accessories to help make the connection between stainless steel chimney liners and your Resolute Ac- claim are available through your local dealer.

Chimney Connector Guidelines

A chimney connector is the double-wall or single-wall pipe that connects the stove to the chimney. The chim- ney itself is a masonry or prefabricated structure that encloses the flue. Chimney connectors are used only to make the connection from the stove to the chimney. They are for interior use only.

Double-wall connectors must be tested and listed for use with solid-fuel burning appliances. Single-wall con- nectors should be made of 24 gauge or heavier steel, and should be 6” (152 mm) in diameter. Do not use

Resolute® Acclaim Woodburning Stove

galvanized chimney connector; it cannot withstand the high temperatures that can be reached by smoke and exhaust gases, and may release toxic fumes under high heat.

If possible, do not pass the chimney connector through a combustible wall or ceiling. If passage through a com- bustible wall is unavoidable, refer to the recommenda- tions in the section following on Wall Pass-Throughs.

Do not pass the connector through an attic, a closet or any similar concealed space. The whole chimney con- nector should be exposed and accessible for inspection and cleaning.

Install the chimney connector not less than 23” (584

mm)from the ceiling. Keep it as short and direct as possible, with no more than two (2) 90° turns. If pos- sible, use 45° elbows. Slope horizontal runs of con- nectors upward 1/4” per foot (20 mm per meter) going from the stove toward the chimney. The recommended maximum length of a horizontal run is 3’ (914 mm), and the total length of chimney connector should be no longer than 8’ (2.5 m).

In cathedral ceiling installations, extend the prefabricat- ed chimney downward to within 8’ (2.5 m) of the stove.

SAFETY NOTE: Always wear gloves and pro- tective eyewear when drilling, cutting or joining sections of chimney connector.

Double-wall Chimney Connectors

The listing for the Resolute Acclaim in the U.S. and Canada includes use of double-wall chimney con- nectors that have been tested and listed for use with solid-fuel burning appliances by a recognized testing laboratory.

Information on assembling and installing double-wall connectors is provided by the manufacturer of the double-wall pipe. Follow the manufacturer’s instructions exactly as you assemble the connector and attach it to the stove and chimney. Using chimneys and connectors from the same manufacturer helps make the assembly and installation straightforward.

NOTE: For installations using double-wall connec- tors, minimum clearances must conform to the listed clearances in the clearance chart on Page 12.

2000893

Image 5
Contents Resolute Acclaim Introduction Table of ContentsAccessories Resolute Acclaim Model SpecificationsMasonry Chimneys InstallationWhat Kind of Chimney to Use Double-wall Chimney Connectors Chimney Connector GuidelinesPrefabricated Chimneys Chimney SizeFreestanding Installations Single-wall Chimney ConnectorsSecuring the Single-wall Connector To a Masonry Chimney Wall Pass-Throughs Above a FireplaceThrough a Fireplace An approved wall pass-through for the United States Floor Protection Floor Protection for Fireplace InstallationSafe Ways to Reduce Clearances Keep the Stove a Safe Distance From Surrounding MaterialsWall Shields Reversing the Flue Collar6mm Fireplace InstallationsParallel Installation Corner Stove Clearance Resolute Acclaim Clearance ChartChimney Connector Clearance Front Clearance To CombustiblesTop Exit, No Heat Shields Stove Installed Stove in Corner Parallel to WallMinimum Wall Shield Requirements for Common Installations Corner Parallel Installations Construction Requirements Alcove InstallationsOperation Install Stove LegsUnpack the Stove Two Controls Operate the StoveRemovable Andirons For Greater Front-Loading Convenience Use the Air Control Settings That Work Best for YouTwo Rules For Success Burn Only High-Quality FuelHow to Build and Sustain a Wood Fire Primary Air SettingsAir Setting Air Control Position Starting and Maintaining a Wood FireSurface Thermometer is a Guide to Performance Reloading and Reviving a Wood FireRemove and Store Ash Safely Rules for Open Fire ViewingClear the Ash Frequently Draft Management Creosote Draft TestingFuel Back-puffingCleaning the Glass MaintenanceClean the Exhaust Channels Care of the Cast Iron SurfaceAdjust the Damper as Needed Adjust the DoorRepair Missing Cement in Seams Avoid Damaging the GlassResolute Acclaim Gaskets on Moving Parts How to Replace GasketsReplace Broken Glass Immediately Replacing the Door Gaskets Gaskets on Resolute Acclaim Stationary PartsReplacing the Griddle Gasket Replace Broken FirebricksYearly Spring Cleaning Resolute Acclaim Maintenance ScheduleDaily Two MonthsItem Description Part Number Resolute Acclaim Woodburning StoveAshlip Door Leg Resolute Acclaim Woodburning StoveWarranty Mhsc

2490 specifications

Acclaim Lighting has made a significant impact in the world of architectural and entertainment lighting with innovative solutions that cater to a wide array of applications. One of their standout products is the Acclaim Lighting 2490, a lighting fixture that exemplifies cutting-edge technology and high performance.

The Acclaim Lighting 2490 is primarily designed for use in both indoor and outdoor settings. Its robust construction ensures durability against various weather conditions, making it an ideal choice for architectural lighting, theatrical productions, and even large-scale events. One of the standout features of the 2490 is its high lumen output, allowing it to provide bright, effective illumination in any scenario.

Equipped with advanced LED technology, the 2490 offers exceptional energy efficiency without compromising brightness. The fixture utilizes high-quality LEDs that not only extend the lifespan of the unit but also minimize heat generation, making it a sustainable choice for long-term use. This energy-efficient operation translates to lower energy costs and reduced environmental impact.

The Acclaim Lighting 2490 boasts versatile color rendering, with RGBW capabilities that allow users to create a wide palette of colors. This feature is particularly beneficial for event lighting and architectural applications where mood and aesthetics play a crucial role. Additionally, the fixture supports DMX control, making it easy to integrate into existing lighting setups and enabling synchronized light shows or dynamic lighting transitions.

Another noteworthy characteristic of the 2490 is its adjustable beam angle. This adaptability provides users with the flexibility to focus light where it's needed most, whether for highlighting architectural features or creating immersive environments for theatrical performances.

Built with user-friendliness in mind, the Acclaim Lighting 2490 includes options for easy mounting and installation. Its lightweight design coupled with intuitive controls ensures that both professional lighting technicians and newcomers can operate it with ease.

Overall, the Acclaim Lighting 2490 stands as a testament to the brand's commitment to quality and innovation in lighting technology. With its combination of efficiency, versatility, and durability, it offers a comprehensive solution for a wide array of lighting needs, making it a preferred choice among lighting designers and professionals alike.