Acclaim Lighting 2490 Gaskets on Resolute Acclaim Stationary Parts, Replacing the Door Gaskets

Page 27

Gaskets on Resolute Acclaim

Stationary Parts

5/16” Between the flue collar and flue collar extension and the stove’s top and back:

5/16” The seal between the upper fireback corners and the lower fireback:

5/16” The seal between the underside of the top plate and the upper edge of the upper fireback

5/16” The damper plate to the reverse side of upper fireback

5/16” The seal between the sealing plates and the vertical ribs of the

stove back

NOTE: When replacing this last gasket after removing the upper fireback, place two (2) cap screws into the upper fireback mounting holes before you cement the channels and replace the gasket. The new gasket will run inside the cap screws. Remove the screws after the gasket cement dries.

Replacing the Door Gaskets

Lift off the door as described previously. Lay it face down on a padded surface.

Follow steps 1-4 on gasket replacement as de- scribed previously.

Replacing the Griddle Gasket

To replace either the damper or the griddle gasket, follow Steps 1-4 on replacing gaskets described previously.

Stove front to door: 1/2” gasket

Grate to stove

front: 1/2” gasketGlass to door frame: 3/16” gasket

ST626

Fig. 39 Two different gasekt sizes are used to seal the front door.

Resolute® Acclaim Woodburning Stove

5/16” Wire Mesh Gasket

5/16” Fiberglass Gasket

ST627

Fig. 40 A 5/16” wire mesh gasket seals the griddle to the stove top. The flue collar is sealed with a 5/16” fiberglass gasket.

Replace Broken Firebricks

If a firebrick breaks, replace only with Vermont Cast- ings’ custom firebricks, available from your local dealer.

MHSC custom firebricks contain metal reinforcements that maintain the brick’s integrity if it cracks. A brick that is cracked but still intact does not need to be replaced.

A Clean Chimney System ss Safer

and Works Better

Learn to Recognize Creosote and Soot

When you first begin using the stove, check daily for creosote — a substance that can look like either thick tar or black, crisp flakes. Experience will show how often you need to clean to be safe. The frequency may even vary during the year. In the colder months when the hottest fires producing the least creosote are burned, you may need to clean less frequently. Dur- ing the warmer months when creosote is more likely to result from cooler-burning fires and weaker draft, more frequent cleaning may be necessary.

At the very least, inspect the chimney and chimney connector twice monthly. Clean if necessary. Let the stove cool to check if a buildup of creosote or soot has occurred. If a significant layer of creosote has accu- mulated—1/8” (3mm) or more—it should be removed to reduce the risk of a chimney fire. Failure to keep the chimney and connector system clean can result in a serious chimney fire.

The conditions for a chimney fire develop like this: When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining.

2000893

27

Image 27
Contents Resolute Acclaim Table of Contents AccessoriesIntroduction Resolute Acclaim Model SpecificationsInstallation What Kind of Chimney to UseMasonry Chimneys Chimney Size Chimney Connector GuidelinesDouble-wall Chimney Connectors Prefabricated ChimneysSingle-wall Chimney Connectors Securing the Single-wall Connector To a Masonry ChimneyFreestanding Installations Above a Fireplace Through a FireplaceWall Pass-Throughs An approved wall pass-through for the United States Floor Protection Floor Protection for Fireplace InstallationReversing the Flue Collar Keep the Stove a Safe Distance From Surrounding MaterialsSafe Ways to Reduce Clearances Wall Shields6mm Fireplace InstallationsFront Clearance To Combustibles Resolute Acclaim Clearance ChartParallel Installation Corner Stove Clearance Chimney Connector ClearanceTop Exit, No Heat Shields Stove Installed Stove in Corner Parallel to WallMinimum Wall Shield Requirements for Common Installations Corner Parallel Installations Construction Requirements Alcove InstallationsTwo Controls Operate the Stove Install Stove LegsOperation Unpack the StoveBurn Only High-Quality Fuel Use the Air Control Settings That Work Best for YouRemovable Andirons For Greater Front-Loading Convenience Two Rules For SuccessStarting and Maintaining a Wood Fire Primary Air SettingsHow to Build and Sustain a Wood Fire Air Setting Air Control PositionSurface Thermometer is a Guide to Performance Reloading and Reviving a Wood FireRules for Open Fire Viewing Clear the Ash FrequentlyRemove and Store Ash Safely Draft Management Back-puffing Draft TestingCreosote Fuel Care of the Cast Iron Surface Maintenance Cleaning the Glass Clean the Exhaust ChannelsAvoid Damaging the Glass Adjust the DoorAdjust the Damper as Needed Repair Missing Cement in SeamsHow to Replace Gaskets Replace Broken Glass ImmediatelyResolute Acclaim Gaskets on Moving Parts Replace Broken Firebricks Gaskets on Resolute Acclaim Stationary PartsReplacing the Door Gaskets Replacing the Griddle GasketTwo Months Resolute Acclaim Maintenance ScheduleYearly Spring Cleaning DailyItem Description Part Number Resolute Acclaim Woodburning StoveAshlip Door Leg Resolute Acclaim Woodburning StoveWarranty Mhsc