Acclaim Lighting 2490 Resolute Acclaim Maintenance Schedule, Daily, Two Months, Two Weeks

Page 28

Resolute® Acclaim Woodburning Stove

When ignited, this creosote makes an extremely hot fire within the flue system which can damage the chimney and overheat adjacent combustible material.

To reduce the amount of creosote that may form, re- member to provide adequate air for combustion and to strive for small, intense fires rather than large, smolder- ing ones.

You can never be too safe. Contact your local fire authority for information on what to do in the event of a chimney fire, and have a clearly understood plan on how to handle one.

Inspect the Chimney Connector and

Chimney Twice Monthly and

Clean as Required

Let the stove cool completely before you inspect the chimney. Then, use a strong light, and sight up through the flue collar into the chimney flue. If it is not possible to inspect the flue system this way, the stove must be disconnected to provide adequate viewing.

Clean the chimney using a specially designed chim- ney cleaning brush, the same size and shape as the flue liner, attached to flexible fiberglass rods designed for this purpose. Run the brush up and down the liner so that any deposits fall to the bottom of the chimney where they can be removed through the clean-out door. The chimney connector should be cleaned by discon- necting the sections, taking them outside, and remov- ing any deposits with a stiff wire brush. Reinstall the connector sections after cleaning, being sure to secure the individual sections with three sheet metal screws per section.

If you are unable to inspect and/or clean the chimney system yourself, contact your local dealer or hire a qualified chimney sweep in your area to do the job.

Resolute Acclaim

Maintenance Schedule

Stove:

Daily:

Ashes should be removed before they reach the top of the ash pan. Check at least once a day.

Keep the area around the stove clear of any com- bustible material.

Two Months:

Check door handle to be sure it is working properly. Gasketing becomes compressed after a period of time.

Check leg bolts and heat shield screws; tighten if necessary.

Vacuum exhaust area on either side of secondary combustion package.

Yearly Spring Cleaning:

Check gasketing for wear, and replace if necessary.

Vacuum exhaust area on either side of secondary combustion package.

Remove ashes from the ash pan and replace with a moisture absorbing material (such as kitty litter) to keep the interior of the stove dry.

Clean the dust from the inner sides of bottom, rear or pipe heat shields if your stove is equipped with them. Clean surfaces are better heat reflectors than dirty surfaces.

Touch up the black paint.

Chimney Connector:

Two Weeks:

Inspect the chimney connector and chimney. Clean if necessary.

Two Months:

Inspect the chimney and chimney connector. Pay particular attention to the horizontal runs of chimney connector, and the elbows. Clean the system if nec- essary.

Yearly Spring Cleaning:

Disassemble the chimney connector and take it outdoors for inspection and cleaning. Replace weak sections of connector.

Inspect the chimney for signs of deterioration. Re- pairs to a masonry chimney should be made by a professional mason. Replace damaged sections of prefabricated chimney. Your local dealer or a chim- ney sweep can help determine when replacement is necessary.

Thoroughly clean the chimney.

28

2000893

Image 28
Contents Resolute Acclaim Accessories Table of ContentsIntroduction Specifications Resolute Acclaim ModelWhat Kind of Chimney to Use InstallationMasonry Chimneys Chimney Connector Guidelines Double-wall Chimney ConnectorsPrefabricated Chimneys Chimney SizeSecuring the Single-wall Connector To a Masonry Chimney Single-wall Chimney ConnectorsFreestanding Installations Through a Fireplace Above a FireplaceWall Pass-Throughs An approved wall pass-through for the United States Floor Protection for Fireplace Installation Floor ProtectionKeep the Stove a Safe Distance From Surrounding Materials Safe Ways to Reduce ClearancesWall Shields Reversing the Flue CollarFireplace Installations 6mmResolute Acclaim Clearance Chart Parallel Installation Corner Stove ClearanceChimney Connector Clearance Front Clearance To CombustiblesStove Installed Stove in Corner Parallel to Wall Top Exit, No Heat ShieldsMinimum Wall Shield Requirements for Common Installations Corner Parallel Installations Alcove Installations Construction RequirementsInstall Stove Legs OperationUnpack the Stove Two Controls Operate the StoveUse the Air Control Settings That Work Best for You Removable Andirons For Greater Front-Loading ConvenienceTwo Rules For Success Burn Only High-Quality FuelPrimary Air Settings How to Build and Sustain a Wood FireAir Setting Air Control Position Starting and Maintaining a Wood FireReloading and Reviving a Wood Fire Surface Thermometer is a Guide to PerformanceClear the Ash Frequently Rules for Open Fire ViewingRemove and Store Ash Safely Draft Management Draft Testing CreosoteFuel Back-puffingMaintenance Cleaning the GlassClean the Exhaust Channels Care of the Cast Iron SurfaceAdjust the Door Adjust the Damper as NeededRepair Missing Cement in Seams Avoid Damaging the GlassReplace Broken Glass Immediately How to Replace GasketsResolute Acclaim Gaskets on Moving Parts Gaskets on Resolute Acclaim Stationary Parts Replacing the Door GasketsReplacing the Griddle Gasket Replace Broken FirebricksResolute Acclaim Maintenance Schedule Yearly Spring CleaningDaily Two MonthsResolute Acclaim Woodburning Stove Item Description Part NumberResolute Acclaim Woodburning Stove Ashlip Door LegWarranty Mhsc

2490 specifications

Acclaim Lighting has made a significant impact in the world of architectural and entertainment lighting with innovative solutions that cater to a wide array of applications. One of their standout products is the Acclaim Lighting 2490, a lighting fixture that exemplifies cutting-edge technology and high performance.

The Acclaim Lighting 2490 is primarily designed for use in both indoor and outdoor settings. Its robust construction ensures durability against various weather conditions, making it an ideal choice for architectural lighting, theatrical productions, and even large-scale events. One of the standout features of the 2490 is its high lumen output, allowing it to provide bright, effective illumination in any scenario.

Equipped with advanced LED technology, the 2490 offers exceptional energy efficiency without compromising brightness. The fixture utilizes high-quality LEDs that not only extend the lifespan of the unit but also minimize heat generation, making it a sustainable choice for long-term use. This energy-efficient operation translates to lower energy costs and reduced environmental impact.

The Acclaim Lighting 2490 boasts versatile color rendering, with RGBW capabilities that allow users to create a wide palette of colors. This feature is particularly beneficial for event lighting and architectural applications where mood and aesthetics play a crucial role. Additionally, the fixture supports DMX control, making it easy to integrate into existing lighting setups and enabling synchronized light shows or dynamic lighting transitions.

Another noteworthy characteristic of the 2490 is its adjustable beam angle. This adaptability provides users with the flexibility to focus light where it's needed most, whether for highlighting architectural features or creating immersive environments for theatrical performances.

Built with user-friendliness in mind, the Acclaim Lighting 2490 includes options for easy mounting and installation. Its lightweight design coupled with intuitive controls ensures that both professional lighting technicians and newcomers can operate it with ease.

Overall, the Acclaim Lighting 2490 stands as a testament to the brand's commitment to quality and innovation in lighting technology. With its combination of efficiency, versatility, and durability, it offers a comprehensive solution for a wide array of lighting needs, making it a preferred choice among lighting designers and professionals alike.