Acclaim Lighting 2490 installation instructions Operation, Unpack the Stove, Install Stove Legs

Page 17

Resolute® Acclaim Woodburning Stove

Operation

You will need the following tools to assemble the Ac-

claim:

 

• 9/16” open end wrench

• safety glasses & gloves

• flat head screwdriver

• power drill w/ 1/8” (3mm) bit

• stub handle phillips screwdriver

Unpack the Stove

1.Remove the shipping straps and plastic wrap.

2.Inspect the stove and contents for shipping damage or missing parts. Immediately notify your dealer of any damage. Do not install this stove if any damage is evident or any parts are missing.

Hardware Bag contents:

Stove Legs, 4

3/8-16 x 1¹⁄₄” hex head Leg Bolts with washers, 4

Owner's Registration Card

Touch-up Paint (Porcelain enamel stoves)

Install Stove Legs

Remove and discard the four large slot-head screws from the stove bottom. Install the stove legs using the hex head bolts from the parts bag. (Fig. 26a) Use 3/8” washers with all four legs. Tighten the bolts firmly.

CAUTION: Overtightening can strip tapped threads.

Leg Leveller

Leg Bolt and

 

 

Washer

ST466

Fig. 26a Attach stove legs and leg levellers.

 

Stove Controls

Two Controls Operate the Stove

The primary air control lever, located beneath the ashlip, regulates how much heat the stove produces by controlling the amount of air received by the fire. The more air supplied, the hotter the fire. (Fig. 27)

With a travel range of about 6” (159 mm), the air con- trol is closed when the lever is fully left. Maximum heat is produced when the lever is fully right. It may also be set anywhere between a “start-up” position and the high and low extremes to achieve a desired heat output. A directional arrow cast into the Acclaim’s ash lip serves

as a reminder of the correct “open” and “closed” posi- tions.

The damper handle is located on the right side of the stove and controls air flow within the stove. (Fig. 27) The damper is open when the handle is toward the rear of the stove, and the combustion gases exit directly out the flue collar. When the handle is pulled forward and locked, the damper is closed, secondary combustion occurs, and the stove operates most efficiently.

The damper must be fully open or fully closed. There are no intermediate positions for the damper handle.

Flue Collar

Top Load Door/Griddle

Damper Handle (not shown)

Griddle Handle

Glass Panel

Front Door

Primary Air Control

Front Door Handle

ST611

Fig. 27 The Resolute Acclaim controls are conveniently located and easy to use.

Two Ways to Add Logs

and a Choice of Fire Views

Convenient top-loading of wood through the Acclaim’s stovetop griddle supplements traditonal fireplace-style loading through the front door.

The griddle simply lifts to open.

The front door employs a rotating cam and a door latch tab to secure it. The handle points down when the door is closed.

To open the front door, pull on the handle to release the cam. To close it, push the door until the latch engages. Double-check the latch by pushing lightly on the handle. When the latch is properly secured, the door will remain closed.

For clear fire viewing, the front door features a large, self-cleaning glass panel. The front door may be opened (or even removed) and the optional spark screen clipped in place for open-fire viewing as well.

2000893

17

Image 17
Contents Resolute Acclaim Introduction Table of ContentsAccessories Resolute Acclaim Model SpecificationsMasonry Chimneys InstallationWhat Kind of Chimney to Use Double-wall Chimney Connectors Chimney Connector GuidelinesPrefabricated Chimneys Chimney SizeFreestanding Installations Single-wall Chimney ConnectorsSecuring the Single-wall Connector To a Masonry Chimney Wall Pass-Throughs Above a FireplaceThrough a Fireplace An approved wall pass-through for the United States Floor Protection Floor Protection for Fireplace InstallationSafe Ways to Reduce Clearances Keep the Stove a Safe Distance From Surrounding MaterialsWall Shields Reversing the Flue Collar6mm Fireplace InstallationsParallel Installation Corner Stove Clearance Resolute Acclaim Clearance ChartChimney Connector Clearance Front Clearance To CombustiblesTop Exit, No Heat Shields Stove Installed Stove in Corner Parallel to WallMinimum Wall Shield Requirements for Common Installations Corner Parallel Installations Construction Requirements Alcove InstallationsOperation Install Stove LegsUnpack the Stove Two Controls Operate the StoveRemovable Andirons For Greater Front-Loading Convenience Use the Air Control Settings That Work Best for YouTwo Rules For Success Burn Only High-Quality FuelHow to Build and Sustain a Wood Fire Primary Air SettingsAir Setting Air Control Position Starting and Maintaining a Wood FireSurface Thermometer is a Guide to Performance Reloading and Reviving a Wood FireRemove and Store Ash Safely Rules for Open Fire ViewingClear the Ash Frequently Draft Management Creosote Draft TestingFuel Back-puffingCleaning the Glass MaintenanceClean the Exhaust Channels Care of the Cast Iron SurfaceAdjust the Damper as Needed Adjust the DoorRepair Missing Cement in Seams Avoid Damaging the GlassResolute Acclaim Gaskets on Moving Parts How to Replace GasketsReplace Broken Glass Immediately Replacing the Door Gaskets Gaskets on Resolute Acclaim Stationary PartsReplacing the Griddle Gasket Replace Broken FirebricksYearly Spring Cleaning Resolute Acclaim Maintenance ScheduleDaily Two MonthsItem Description Part Number Resolute Acclaim Woodburning StoveAshlip Door Leg Resolute Acclaim Woodburning StoveWarranty Mhsc

2490 specifications

Acclaim Lighting has made a significant impact in the world of architectural and entertainment lighting with innovative solutions that cater to a wide array of applications. One of their standout products is the Acclaim Lighting 2490, a lighting fixture that exemplifies cutting-edge technology and high performance.

The Acclaim Lighting 2490 is primarily designed for use in both indoor and outdoor settings. Its robust construction ensures durability against various weather conditions, making it an ideal choice for architectural lighting, theatrical productions, and even large-scale events. One of the standout features of the 2490 is its high lumen output, allowing it to provide bright, effective illumination in any scenario.

Equipped with advanced LED technology, the 2490 offers exceptional energy efficiency without compromising brightness. The fixture utilizes high-quality LEDs that not only extend the lifespan of the unit but also minimize heat generation, making it a sustainable choice for long-term use. This energy-efficient operation translates to lower energy costs and reduced environmental impact.

The Acclaim Lighting 2490 boasts versatile color rendering, with RGBW capabilities that allow users to create a wide palette of colors. This feature is particularly beneficial for event lighting and architectural applications where mood and aesthetics play a crucial role. Additionally, the fixture supports DMX control, making it easy to integrate into existing lighting setups and enabling synchronized light shows or dynamic lighting transitions.

Another noteworthy characteristic of the 2490 is its adjustable beam angle. This adaptability provides users with the flexibility to focus light where it's needed most, whether for highlighting architectural features or creating immersive environments for theatrical performances.

Built with user-friendliness in mind, the Acclaim Lighting 2490 includes options for easy mounting and installation. Its lightweight design coupled with intuitive controls ensures that both professional lighting technicians and newcomers can operate it with ease.

Overall, the Acclaim Lighting 2490 stands as a testament to the brand's commitment to quality and innovation in lighting technology. With its combination of efficiency, versatility, and durability, it offers a comprehensive solution for a wide array of lighting needs, making it a preferred choice among lighting designers and professionals alike.