Bradford-White Corp M1XR403S*FCX, CX), MI50L, MI504S, MI60T service manual MI30T*FBN,CX M430T*FBN,CX

Page 1

The Bradford White

Flammable Vapor Ignition Resistant Water Heater

SERVICE

MANUAL

Troubleshooting Guide

and Instruction for Service

(To be performed ONLY by qualified service providers)

For the Bradford White

Defender Safety System® Models:

MI30T*F(BN,CX) M430T*F(BN,CX)

MI30S*F(BN, CX) M440T*F(BN, CX)

MI303T*F(BN,CX) M4403S*F(BN,CX)

MI40T*F(BN,CX) M4403T*F(BN,CX)

MI403S*F(BN,CX) M450S*F(BN,CX)

MI404T*F(BN,CX) M4503*F(BN,CX)

MI503*F(BN,CX) M460T*F(BN,CX)

MI50L*F(BN,CX) M1XR403S*F(BN,CX)

MI504S*F(BN,CX) M1XR504T*F(BN,CX)

MI60T*F(BN,CX) M2XR504T*F(BN,CX) M2C504T*F(BN,CX) 50T65F(BN,CX)

(*) Denotes Warranty Years.

Save this manual for future reference

Manual 44943C

Image 1
Contents MI50L*FBN,CX M1XR403S*FBN,CX MI504S*FBN,CX M1XR504T*FBN,CX MI30T*FBN,CX M430T*FBN,CXMI60T*FBN,CX M2XR504T*FBN,CX M2C504T*FBN,CX 50T65FBN,CX Table of Contents Introduction Bradford White Defender Safety SystemFlammable Vapor Ignition Resistant Water Heaters Troubleshooting ChartProceed to Inner Door Gasket Replacement Procedure Service Procedure RG-IFollowed exactly, a fire or explosion may result causing If the information in these instructions is notInstallation of Inner Door With Gasket Replace outer jacket burner access door Thermocouple Testing and Replacement Service Procedure RG-IIClosed Circuit Thermocouple Testing White Rodgers Control Closed Circuit Thermocouple Testing Robertshaw ControlThermocouple Replacement Open Circuit Thermocouple TestingPilot Assembly Inspection, Cleaning and Replacement Service Procedure RG-IIIPiezo Igniter, Electrode Testing and Replacement Service Procedure RG-IVPiezo IGNITER, Electrode Testing and Replacement Combination Thermostat/Gas Valve Testing Replacement Service Procedure RG-VCombination Thermostat/Gas Valve Testing and Replacement Line PressureMagnet Assembly Testing White Rodgers Control Thermocouple TestingMagnet Assembly Testing Robertshaw Control Combination THERMOSTAT/GAS Valve Replacement ECO Energy Cut Off TestingWrench Boss Seal breach may result in a fire or Explosion causing property damagePersonal injury or death Main Burner Inspection, Adjustment Cleaning and Replacement Service Procedure RG-VICast Iron Burner Adjustment Feedline Burner Cleaning Resetting Thermal Switch Testing and Replacement Service Procedure RG-VIIResettable Thermal Switch Continuity Testing Over Tighten Screws Resettable Thermal Switch ReplacementScreenLok Flame Arrestor Cleaning Service Procedure RG-VIIIScreenLok Flame Arrestor Cleaning Dip Tube and Anode Inspection and Replacement Service Procedure RG-IXDIP Tube Inspection and Replacement Anode Inspection and Replacement Parts List Page Page Fax/215-641-1612
Related manuals
Manual 40 pages 36.32 Kb