Bradford-White Corp Essential Bradford White Water Heater Parts List

Page 25

PARTS LIST

1

Draft Hood

20

Pilot Assembly

2

Hot Water Outlet/Anode

21

Pilot Orifice

3

Cold Water Inlet Tube

22

Thermocouple

4

Flue Baffle

23

Feed Line

5

T&P Relief Valve

24

Complete Cast Iron Burner Assembly

6

Thermostat

25

Cast Iron Burner Only

7

Piezo Igniter

26

Main Burner Orifice

8

Brass Drain Valve

27

Pilot Assembly

9

Screw-#8-18 x 3/4 Hex Washer Head

28

Pilot Orifice

10

Screw-#10-12 x 3/4 Hex Washer Head

29

Air Shutter

11

Left Side Inner Door with Gasket

30

Air Shutter Nut

12

Complete Right Side Inner Door

31

Thermocouple

14

Resettable Thermal Switch

32

Feed Line

15

Screw #6-20 x 3/8 PHCR

33

ASSE Approved Mixing Valve (Optional)

16

Outer Door

34

¾ NPT Tank Plug (XR models)

17

Complete BN Burner Assembly

35

Inner Door Gasket Kit

18

BN Burner Only

36

Wire Tie

19

Main Burner Orifice

 

 

26

Image 25
Contents MI50L*FBN,CX M1XR403S*FBN,CX MI504S*FBN,CX M1XR504T*FBN,CX MI30T*FBN,CX M430T*FBN,CXMI60T*FBN,CX M2XR504T*FBN,CX M2C504T*FBN,CX 50T65FBN,CX Table of Contents Introduction Bradford White Defender Safety SystemFlammable Vapor Ignition Resistant Water Heaters Troubleshooting ChartProceed to Inner Door Gasket Replacement Procedure Service Procedure RG-IFollowed exactly, a fire or explosion may result causing If the information in these instructions is notInstallation of Inner Door With Gasket Replace outer jacket burner access door Thermocouple Testing and Replacement Service Procedure RG-IIClosed Circuit Thermocouple Testing White Rodgers Control Closed Circuit Thermocouple Testing Robertshaw ControlThermocouple Replacement Open Circuit Thermocouple TestingPilot Assembly Inspection, Cleaning and Replacement Service Procedure RG-IIIPiezo Igniter, Electrode Testing and Replacement Service Procedure RG-IVPiezo IGNITER, Electrode Testing and Replacement Combination Thermostat/Gas Valve Testing Replacement Service Procedure RG-VCombination Thermostat/Gas Valve Testing and Replacement Line PressureMagnet Assembly Testing White Rodgers Control Thermocouple TestingMagnet Assembly Testing Robertshaw Control Combination THERMOSTAT/GAS Valve Replacement ECO Energy Cut Off TestingWrench Boss Seal breach may result in a fire or Explosion causing property damagePersonal injury or death Main Burner Inspection, Adjustment Cleaning and Replacement Service Procedure RG-VICast Iron Burner Adjustment Feedline Burner Cleaning Resetting Thermal Switch Testing and Replacement Service Procedure RG-VIIResettable Thermal Switch Continuity Testing Over Tighten Screws Resettable Thermal Switch ReplacementScreenLok Flame Arrestor Cleaning Service Procedure RG-VIIIScreenLok Flame Arrestor Cleaning Dip Tube and Anode Inspection and Replacement Service Procedure RG-IXDIP Tube Inspection and Replacement Anode Inspection and Replacement Parts List Page Page Fax/215-641-1612
Related manuals