SERVICE PROCEDURE RG-IV

Piezo Igniter, Electrode Testing and Replacement

PIEZO IGNITER, ELECTRODE TESTING AND REPLACEMENT

With the pilot not in operation (no pilot flame) you can check the Piezo and electrode circuit by viewing pilot thru the sight glass located on the inner door and observing the spark action.

Step 1. Remove outer jacket door.

Step 2. Repeatedly depress the Piezo igniter while viewing the pilot thru the sight glass. If a spark is present, the circuit is OK. If there is no spark, proceed to step 3.

View spark

Action through

Repeatedly

Sight glass

Depress Piezo

Igniter

Step 3 Remove orange wire from Piezo igniter and install a jumper wire in its place. Hold the other end of the jumper by the wire insulation or using an insulated tool, next to an unpainted surface such as the feedline or gas valve and depress the Piezo igniter. If there is a spark, the igniter is OK, the pilot is not functioning and must be replaced, see SERVICE PROCEDURE RG-III for pilot replacement. If no spark is present the igniter is not functioning and must be replaced.

Step 4 With orange wire disconnected from piezo igniter. Using a common screw driver, place blade of screw driver under piezo bracket and gently pry bracket from front of combination thermostat/ gas valve and unhook bracket from rear of combination thermostat/gas valve.

Common Screw

Driver

12

Image 11
Contents MI60T*FBN,CX M2XR504T*FBN,CX M2C504T*FBN,CX 50T65FBN,CX MI30T*FBN,CX M430T*FBN,CXMI50L*FBN,CX M1XR403S*FBN,CX MI504S*FBN,CX M1XR504T*FBN,CX Table of Contents Introduction Bradford White Defender Safety SystemFlammable Vapor Ignition Resistant Water Heaters Troubleshooting ChartIf the information in these instructions is not Service Procedure RG-IProceed to Inner Door Gasket Replacement Procedure Followed exactly, a fire or explosion may result causingInstallation of Inner Door With Gasket Replace outer jacket burner access door Closed Circuit Thermocouple Testing Robertshaw Control Service Procedure RG-IIThermocouple Testing and Replacement Closed Circuit Thermocouple Testing White Rodgers ControlThermocouple Replacement Open Circuit Thermocouple TestingPilot Assembly Inspection, Cleaning and Replacement Service Procedure RG-IIIPiezo IGNITER, Electrode Testing and Replacement Service Procedure RG-IVPiezo Igniter, Electrode Testing and Replacement Line Pressure Service Procedure RG-VCombination Thermostat/Gas Valve Testing Replacement Combination Thermostat/Gas Valve Testing and ReplacementMagnet Assembly Testing Robertshaw Control Thermocouple TestingMagnet Assembly Testing White Rodgers Control Combination THERMOSTAT/GAS Valve Replacement ECO Energy Cut Off TestingWrench Boss Personal injury or death Explosion causing property damageSeal breach may result in a fire or Cast Iron Burner Adjustment Service Procedure RG-VIMain Burner Inspection, Adjustment Cleaning and Replacement Feedline Burner Cleaning Resettable Thermal Switch Continuity Testing Service Procedure RG-VIIResetting Thermal Switch Testing and Replacement Over Tighten Screws Resettable Thermal Switch ReplacementScreenLok Flame Arrestor Cleaning Service Procedure RG-VIIIScreenLok Flame Arrestor Cleaning DIP Tube Inspection and Replacement Service Procedure RG-IXDip Tube and Anode Inspection and Replacement Anode Inspection and Replacement Parts List Page Page Fax/215-641-1612