Bradford-White Corp MI503 Seal breach may result in a fire or, Explosion causing property damage

Page 16

SERVICE PROCEDURE RG-V

Combination Thermostat/Gas Valve Testing

and Replacement

Step 9. Reinstallation of inner door assembly. (cont.)

b)Clean any gasket residue or other debris from combustion chamber surface before installing the inner door/gasket assembly.

c)Position thermocouple, pilot tube and Piezo wire against left side inner door flange gasket. DO NOT ROUTE THROUGH RADIUSED CHANNEL WITH FEEDLINE. Be sure that thermocouple and pilot tube are not in position to interfere with outer jacket burner access door when reinstalled.

WARNING

A seal breach may result in a fire or

explosion causing property damage,

personal injury or death.

Position thermocouple, pilot tube and Piezo wire.

d)Firmly place right side inner door flange against the left side inner door flange and secure with two ¼” hex drive screws from step 6c. DO NOT OVER TIGHTEN SCREWS.

e)Align right side inner door to combustion chamber and verify the fastener holes of the combustion chamber are aligned with the right side inner door slotted openings. Verify seal integrity around combustion opening. Secure right side inner door using 1/4” hex drive screws from step 6b. DO NOT OVER TIGHTEN

SCREWS. Verify both left and right sides of the inner door are properly positioned and sealed against the combustion chamber.

Secure flange with

¼" drive screws.

Verify threaded hole alignment with slotted openings in inner door.

Step 10. Reconnect wire leads from combination thermostat/gas valve to resettable thermal switch (See photo in step

6). Note: wire terminations are interchangeable with either resettable thermal switch connection.

Step 11. Replace outer jacket burner access door.

Step 12. Reconnect gas supply to Combination Thermostat/Gas Valve.

Step 13. Resume water supply to water heater. Be sure tank is full of water.

Step 14. To resume operation follow the instructions located on the lighting instruction label or the lighting instructions located in the installation and operation manual.

17

Image 16
Contents MI50L*FBN,CX M1XR403S*FBN,CX MI504S*FBN,CX M1XR504T*FBN,CX MI30T*FBN,CX M430T*FBN,CXMI60T*FBN,CX M2XR504T*FBN,CX M2C504T*FBN,CX 50T65FBN,CX Table of Contents Bradford White Defender Safety System IntroductionTroubleshooting Chart Flammable Vapor Ignition Resistant Water HeatersService Procedure RG-I Proceed to Inner Door Gasket Replacement ProcedureFollowed exactly, a fire or explosion may result causing If the information in these instructions is notInstallation of Inner Door With Gasket Replace outer jacket burner access door Service Procedure RG-II Thermocouple Testing and ReplacementClosed Circuit Thermocouple Testing White Rodgers Control Closed Circuit Thermocouple Testing Robertshaw ControlOpen Circuit Thermocouple Testing Thermocouple ReplacementService Procedure RG-III Pilot Assembly Inspection, Cleaning and ReplacementPiezo Igniter, Electrode Testing and Replacement Service Procedure RG-IVPiezo IGNITER, Electrode Testing and Replacement Service Procedure RG-V Combination Thermostat/Gas Valve Testing ReplacementCombination Thermostat/Gas Valve Testing and Replacement Line PressureMagnet Assembly Testing White Rodgers Control Thermocouple TestingMagnet Assembly Testing Robertshaw Control ECO Energy Cut Off Testing Combination THERMOSTAT/GAS Valve ReplacementWrench Boss Seal breach may result in a fire or Explosion causing property damagePersonal injury or death Main Burner Inspection, Adjustment Cleaning and Replacement Service Procedure RG-VICast Iron Burner Adjustment Feedline Burner Cleaning Resetting Thermal Switch Testing and Replacement Service Procedure RG-VIIResettable Thermal Switch Continuity Testing Resettable Thermal Switch Replacement Over Tighten ScrewsScreenLok Flame Arrestor Cleaning Service Procedure RG-VIIIScreenLok Flame Arrestor Cleaning Dip Tube and Anode Inspection and Replacement Service Procedure RG-IXDIP Tube Inspection and Replacement Anode Inspection and Replacement Parts List Page Page Fax/215-641-1612