Bradford-White Corp D-38T-155 service manual Error Code Definitions

Page 22

Troubleshooting

ERROR CODE DEFINITIONS

If the water heater has an operating problem, there will be a number in the water heater display with “Service Needed” shown below the error code number. Note the error code and the definition in the chart below. This label appears on the control box under the water heater display. The following sections will provide instructions for servicing each error code.

Page 22

22

Image 22
Contents Service Manual To be performed only by qualified service providersTable of Contents Features of Honeywell Integrated Controls System Tools Required for Service Specifications Sequence of Operation Lockout ConditionVoltage at primary pins 1&3 white TroubleshootingPins to black and white wires DefectiveFrom previous Displaying temperature SensorsExample of error code shown on control display Operate?Using Control Display for Servicing Water Heater Sensor is used Setpoint Display/Change Software Version Display only Select SET ExitingSELECTServiceSETMode Display of Water TemperatureTo Display and Change Temperature Setpoint To Display Flame Sense Current of the Pilot Flame SensorSetpoint Flashes Selectset Idle Status Operational Error Codes and Error History Display Error Code HistoryTo view previous error codes ExitingSELECTServiceSET Mode Error Code Definitions Error Code Shown Water Heater Display Press for 3 seconds to reset control in service modeDo not reset the display from the hard lockout Service Procedure D24-IThermostat Circuit Testing State without correcting the causeService Procedure D24-I Lower Sensor Upper SensorUpper thermister location Applicable models Pilot Operation Testing Service Procedure D24-II131 Pilot Inspection Meter Probe Micro-amp readings MeterProbe Micro Amp =Main Burner Operation Testing Service Procedure D24-III114 See Pilot Inspection section Build-up causing restrictionHeater. Refer to Installation Instructions InspectionMain Burner Removal Service Procedure D24-IVMain Burner & Pilot Removal and Inspection Main Burner InspectionFlame Rod Pilot Burner RemovalPilot Burner Inspection Ferrule NutControl board replacement Control Board ReplacementTo remove lower sensor Service Procedure D24-V Flue Baffle Removal, InspectionService Procedure D24-VI Approximate Anode Rod Locations Generic Parts List 15A 16/16A 17/17A13A 14A 16A 17A6A 11A 10A 18A 15A 19A 12A 20A 19B 20B 17B18B 16B 12B10B 13B 14B 15BECO BTU/HCO2 GFIPage Page Parts@bradfordwhite.com Techserv@bradfordwhite.com