Troubleshooting
CAUTION |
Use Caution Not to Damage Connectors when making Voltage Measurements or Jumping Terminals |
Water Heater Fault: Water heater does not operate
Display Error Code: Water heater display does not operate - blank display
Check main power supply to water | 1 | ||
heater - fuse, circuit breaker, plug |
|
| |
receptacle, line cord or wiring to |
|
| |
water heater. |
|
| |
|
|
| |
|
|
|
|
Check to make sure switch on top of |
|
| |
control panel is in the ON position |
| Checking line voltage to board. | |
|
|
| |
|
|
| Pins to black and white wires. |
|
|
| Voltage at primary pins 1&3 (white and |
|
|
| |
Verify Primary and Secondary |
| black wires) should be | |
voltage at the control board. |
| check Line In pins 1&4. Check line cord | |
|
|
| with ohmeter. Replace line cord if |
|
|
| defective. |
2
Checking primary voltage to
transformer from board. Pins to
black and white wires.
3 | 4 |
If there is not 24 volts at Secondary pins on the control board, check transformer. Replace transformer or wire harness.
Does water heater display operate? Does damper begin to open?
Increase thermostat setting if tank is
warm and make sure the control display status reads “Heating”.
Y
See next page
Checking secondary voltage from transformer. Pins to blue and yellow wires.
NCheck wire connections of
board to display. See
illustration.
5
Checking transformer voltage, front terminals are 24 volts, rear terminals are 120 volts.
With the control cover tilted down,
measure the voltage between red and black wire pin connections to display.
Voltage should be 24 volts AC
measured at the back of the Control
Display.
If no voltage at Display, check wire harnesses and voltage at
Replace display if voltage is present at display pin terminals. Replace control board if no voltage is present at E- com terminals (1&3,
Page 7