Bradford-White Corp D-38T-155 service manual Service Procedure D24-IV, Main Burner Removal

Page 32

SERVICE PROCEDURE D24-IV

Main Burner & Pilot

Removal and Inspection

WARNING

Heater components may be HOT when performing the following steps in this procedure.

Take necessary precaution to prevent personal injury.

Main Burner Removal

 

 

 

 

Gas Valve

Step 1.

Disconnect (un-plug) water heater from

 

Control Knob

 

 

 

 

electrical supply.

Gas Supply

 

 

 

 

 

Step 2.

Turn “OFF” gas supply to water heater.

Line

 

 

 

 

Step 3.

Rotate gas valve control knob to the “OFF” position

 

(see photo 17).

 

 

17

Step 4.

Disconnect Gas supply line from the gas valve

 

 

(see photo 17).

 

 

 

Step 5.

Disconnect wire leads from gas valve

 

Pilot Flame Sense

 

 

Wire (White)

 

(see photo 17).

 

 

 

 

 

 

Step 6.

Disconnect white flame sense wire & orange ignition

 

wire from Control Board (see photo 18).

 

 

Step 7.

Remove the two burner rack mounting screws (see photo 17).

Step 8.

Slide complete burner rack out from heater

 

 

 

(see photo 19).

 

 

 

Step 9.

To install burner, reverse above procedure.

 

 

Step 10.

Check for gas leaks and verify proper operation.

 

Main Burner Inspection

Step 1. Burner tubes should be free of any flue

scale or other debris. Clean

burner tubes using a stiff brush and/or shop vac. Burner ports should have uniform openings. Replacement is recommended for burners where port area is deteriorated or other unintended openings are present.

Step 2. Insure pilot shield is in place (see photo 20).

Step 3. Inspect pilot position to insure smooth burner ignition from pilot flame. Pilot should be mounted using the two mounting screws through the burner support bracket resulting in a level pilot position.

18

19

20

Gas Valve

Wire Leads

Burner Rack

Mounting

Screw

Pilot spark wire

(Orange)

Pilot

Shield

Page 32

32

Image 32
Contents Service Manual To be performed only by qualified service providersTable of Contents Features of Honeywell Integrated Controls System Tools Required for Service Specifications Sequence of Operation Lockout ConditionTroubleshooting Pins to black and white wiresVoltage at primary pins 1&3 white DefectiveDisplaying temperature Sensors Example of error code shown on control displayFrom previous Operate?Using Control Display for Servicing Water Heater Sensor is used Setpoint Display/Change Software Version Display only Select SET ExitingSELECTServiceSETMode Display of Water TemperatureTo Display and Change Temperature Setpoint To Display Flame Sense Current of the Pilot Flame SensorSetpoint Flashes Selectset Idle Status Operational Error Codes and Error History Display Error Code HistoryTo view previous error codes ExitingSELECTServiceSET Mode Error Code Definitions Error Code Shown Water Heater Display Press for 3 seconds to reset control in service modeService Procedure D24-I Thermostat Circuit TestingDo not reset the display from the hard lockout State without correcting the causeService Procedure D24-I Upper thermister location Applicable models Upper SensorLower Sensor 131 Service Procedure D24-IIPilot Operation Testing Pilot Inspection Micro-amp readings Meter ProbeMeter Probe Micro Amp =114 Service Procedure D24-IIIMain Burner Operation Testing Build-up causing restriction Heater. Refer to Installation InstructionsSee Pilot Inspection section InspectionService Procedure D24-IV Main Burner & Pilot Removal and InspectionMain Burner Removal Main Burner InspectionPilot Burner Removal Pilot Burner InspectionFlame Rod Ferrule NutTo remove lower sensor Control Board ReplacementControl board replacement Service Procedure D24-V Flue Baffle Removal, InspectionService Procedure D24-VI Approximate Anode Rod Locations Generic Parts List 15A 16/16A 17/17A13A 14A 16A 17A6A 11A 10A 18A 15A 19A 12A 20A 19B 20B 17B18B 16B 12B10B 13B 14B 15BBTU/H CO2ECO GFIPage Page Parts@bradfordwhite.com Techserv@bradfordwhite.com