Bradford-White Corp D-38T-155 service manual 13A 14A 16A 17A6A 11A 10A 18A 15A 19A 12A 20A

Page 39

Generic Parts List

13A

4A

1A

2A

14A

3A

16A

5A

17A6A

11A

7A

8A

9A

10A

18A

15A

19A

12A

20A

1A.

Draft Panel

11A.

Pilot Mounting Screw

2A.

Burner Rack

12A.

Burner Tube Support

3A.

Burner Tube

13A.

Manifold Bracket

4A.

Gas Valve

14A.

C-Cane Manifold

5A.

Burner Manifold

15A.

Manifold Straight

6A.

Main Burner Orifice

16A.

Manifold Bracket

7A.

Pilot Shield

17A.

90° Street Elbow Black

8A.

Pilot Burner

18A.

1" Down Pipe Nipple Black

9A.

Pilot Orifice

19A.

1" 90° Elbow Black

10A. Pilot Tubing

20A.

Ground Wire

 

 

Page 39

39

Image 39
Contents To be performed only by qualified service providers Service ManualTable of Contents Features of Honeywell Integrated Controls System Tools Required for Service Specifications Lockout Condition Sequence of OperationDefective TroubleshootingPins to black and white wires Voltage at primary pins 1&3 whiteOperate? Displaying temperature SensorsExample of error code shown on control display From previousUsing Control Display for Servicing Water Heater Sensor is used Setpoint Display/Change Software Version Display only Select SET Display of Water Temperature ExitingSELECTServiceSETModeTo Display Flame Sense Current of the Pilot Flame Sensor To Display and Change Temperature SetpointSetpoint Flashes Selectset Idle Status Operational Error Code History Error Codes and Error History DisplayTo view previous error codes ExitingSELECTServiceSET Mode Error Code Definitions Press for 3 seconds to reset control in service mode Error Code Shown Water Heater DisplayState without correcting the cause Service Procedure D24-IThermostat Circuit Testing Do not reset the display from the hard lockoutService Procedure D24-I Upper Sensor Lower SensorUpper thermister location Applicable models Service Procedure D24-II Pilot Operation Testing131 Pilot Inspection Micro Amp = Micro-amp readings MeterProbe Meter ProbeService Procedure D24-III Main Burner Operation Testing114 Inspection Build-up causing restrictionHeater. Refer to Installation Instructions See Pilot Inspection sectionMain Burner Inspection Service Procedure D24-IVMain Burner & Pilot Removal and Inspection Main Burner RemovalFerrule Nut Pilot Burner RemovalPilot Burner Inspection Flame RodControl Board Replacement Control board replacementTo remove lower sensor Flue Baffle Removal, Inspection Service Procedure D24-VService Procedure D24-VI Approximate Anode Rod Locations 15A 16/16A 17/17A Generic Parts List13A 14A 16A 17A6A 11A 10A 18A 15A 19A 12A 20A 14B 15B 19B 20B 17B18B 16B 12B10B 13BGFI BTU/HCO2 ECOPage Page Parts@bradfordwhite.com Techserv@bradfordwhite.com