FEATURES OF HONEYWELL INTEGRATED CONTROLS SYSTEM

Attractive digital water heater display on control panel for setting and displaying the temperature setpoint. Pressing temperature up and down buttons changes the temperature setpoint. Temperature format may be displayed in degrees F or degrees C.

Single control board with plug in wiring controls temperature, ignition, and flue damper operation.

Reduced number of parts for servicing and wiring.

Plug in wiring reduces chance of miswiring.

Water heater display will show diagnostic codes in the event the water heater needs servicing. Aids in diagnosing and servicing the water heater.

Water heater display can show up to 10 previous error codes in the service mode to further aid in servicing the water heater.

Page 3

3

Image 3
Contents To be performed only by qualified service providers Service ManualTable of Contents Features of Honeywell Integrated Controls System Tools Required for Service Specifications Lockout Condition Sequence of OperationDefective TroubleshootingPins to black and white wires Voltage at primary pins 1&3 whiteOperate? Displaying temperature SensorsExample of error code shown on control display From previousUsing Control Display for Servicing Water Heater Sensor is used Setpoint Display/Change Software Version Display only Select SET Display of Water Temperature ExitingSELECTServiceSETModeTo Display Flame Sense Current of the Pilot Flame Sensor To Display and Change Temperature SetpointSetpoint Flashes Selectset Idle Status Operational Error Code History Error Codes and Error History DisplayTo view previous error codes ExitingSELECTServiceSET Mode Error Code Definitions Press for 3 seconds to reset control in service mode Error Code Shown Water Heater DisplayState without correcting the cause Service Procedure D24-IThermostat Circuit Testing Do not reset the display from the hard lockoutService Procedure D24-I Upper Sensor Lower SensorUpper thermister location Applicable models Service Procedure D24-II Pilot Operation Testing131 Pilot Inspection Micro Amp = Micro-amp readings MeterProbe Meter ProbeService Procedure D24-III Main Burner Operation Testing114 Inspection Build-up causing restrictionHeater. Refer to Installation Instructions See Pilot Inspection sectionMain Burner Inspection Service Procedure D24-IVMain Burner & Pilot Removal and Inspection Main Burner RemovalFerrule Nut Pilot Burner RemovalPilot Burner Inspection Flame RodControl Board Replacement Control board replacementTo remove lower sensor Flue Baffle Removal, Inspection Service Procedure D24-VService Procedure D24-VI Approximate Anode Rod Locations 15A 16/16A 17/17A Generic Parts List13A 14A 16A 17A6A 11A 10A 18A 15A 19A 12A 20A 14B 15B 19B 20B 17B18B 16B 12B10B 13BGFI BTU/HCO2 ECOPage Page Parts@bradfordwhite.com Techserv@bradfordwhite.com