Bradford-White Corp D-38T-155 See Pilot Inspection section, Build-up causing restriction

Page 31

SERVICE PROCEDURE D24-III

Main Burner Operation Testing

DANGER

120 volt exposure. To avoid personal injury, use caution while performing this procedure.

CAUTION

Be Careful When Making Voltage

Measurements or Jumping Terminals

Not to Damage or Deform Connectors or

Connector Pins.

Condition:

Main burner short cycles.

Control Display may show error

code “63, 57, or 4” and be in

“Soft Lockout” state.

Check gas inlet pressure to the water

 

 

 

 

 

heater gas valve.

 

 

 

 

 

Line pressure should be:

 

Determine cause of incorrect gas

 

 

Nat. = Min. 5.5" W.C.: Max. 14.0" W.C.

 

pressure and correct. Contact

 

 

N

 

 

LP = Min. 11.0" W.C.; Max. 14.0" W.C.

your gas supplier.

 

 

 

 

 

Is gas pressure within proper

 

 

 

 

 

specification? (see photo below)

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

Check manifold pressure. See photo on lower right section of page for

 

 

manifold pressure tap location. Refer to water heater rating label for

 

 

specified manifold pressure. If the manifold pressure is not within 0.3"

N

 

w.c. of the specified pressure, then remove the regulator cap from the

 

Replace Gas Valve.

gas valve and turn plastic screw clockwise to increase pressure and

 

 

 

counterclockwise to decrease pressure. Be sure inlet gas pressure is at least 1" w.c. above the manifold pressure. Replace regulator screw and pressure tap cap when finished. Is manifold pressure O.K.?

Y

Check venting conditions, clogged vent,

down drafts or negative building

pressure

Is vent system okay?

Y

Is there sufficient combustion air being supplied to the water heater? Are there combustion air openings or supply pipes to the room? Open access door to the utility room to see if problem is corrected.

Y

Check for unstable pilot flame or oxidation of the flame rod on pilot causing weak pilot signal. Make sure pilot shield is in place and does not touch pilot flame sensor.

(See Pilot Inspection section)

Check burner tubes for scale or debris build-up. Clean burner as necessary.

(see Main Burner and Pilot Removal and

Inspection)

Check tank flues for blockage or debris

build-up causing restriction.

(see Flue Baffle Removal, Inspection)

N Correct improper venting condition. Refer to

Installation Instructions

Line gas

Gas Valve pressure

pressure port

regulator cap (adjustment

 

screw accessible by

 

removing cap screw)

 

Provide proper

 

N

combustion air to water

16

 

heater. Refer to

 

Installation Instructions

Connect hose barb to manifold pressure port shown above, then connect monometer to measure gas manifold pressure.

Manifold Pressure Port with hose

barb inserted for measuring

pressure

Page 31

31

Image 31
Contents To be performed only by qualified service providers Service ManualTable of Contents Features of Honeywell Integrated Controls System Tools Required for Service Specifications Lockout Condition Sequence of OperationDefective TroubleshootingPins to black and white wires Voltage at primary pins 1&3 whiteOperate? Displaying temperature SensorsExample of error code shown on control display From previousUsing Control Display for Servicing Water Heater Sensor is used Setpoint Display/Change Software Version Display only Select SET Display of Water Temperature ExitingSELECTServiceSETModeTo Display Flame Sense Current of the Pilot Flame Sensor To Display and Change Temperature SetpointSetpoint Flashes Selectset Idle Status Operational Error Code History Error Codes and Error History DisplayTo view previous error codes ExitingSELECTServiceSET Mode Error Code Definitions Press for 3 seconds to reset control in service mode Error Code Shown Water Heater DisplayState without correcting the cause Service Procedure D24-IThermostat Circuit Testing Do not reset the display from the hard lockoutService Procedure D24-I Lower Sensor Upper SensorUpper thermister location Applicable models Pilot Operation Testing Service Procedure D24-II131 Pilot Inspection Micro Amp = Micro-amp readings MeterProbe Meter ProbeMain Burner Operation Testing Service Procedure D24-III114 Inspection Build-up causing restrictionHeater. Refer to Installation Instructions See Pilot Inspection sectionMain Burner Inspection Service Procedure D24-IVMain Burner & Pilot Removal and Inspection Main Burner RemovalFerrule Nut Pilot Burner RemovalPilot Burner Inspection Flame RodControl board replacement Control Board ReplacementTo remove lower sensor Flue Baffle Removal, Inspection Service Procedure D24-VService Procedure D24-VI Approximate Anode Rod Locations 15A 16/16A 17/17A Generic Parts List13A 14A 16A 17A6A 11A 10A 18A 15A 19A 12A 20A 14B 15B 19B 20B 17B18B 16B 12B10B 13BGFI BTU/HCO2 ECOPage Page Parts@bradfordwhite.com Techserv@bradfordwhite.com