Blending Valve

In some situations, the blending valve may be used to decrease water softness. The amount of hardness blended back into the water line is determined by the hardness of the incoming water and the setting of the blending valve. Where extremely hard water is present, the blending valve may only need to be “cracked” open. Where the incoming water has relatively low levels of hardness, the blending valve will need to be opened further.

The blending valve is located between the input and output connections on the top of the bypass valve. See Figure 3. It is adjusted by placing a flat blade screwdriver in the slot provided and turning clockwise to open. Total movement of the blending valve from full closed to full open is 1/4 revolution. Precise setting of the blending valve will require “trial and error” testing. The initial setting should be conservative. Because of the blending valve’s ease of access and adjustment, the user can increase or decrease the setting according to their preference over a period of time.

Use of the blending valve is not recommended where objectionable concentrations of ferrous iron or sediment are present. Because the blending valve is mixing “raw” water with softened, any ferrous iron or sediment in the “raw” water will also be blended and reintroduced into the softened water line.

Note: If the appliance is installed for barium and/or radium reduction, the blending valve must remain in the fully closed position at all times.

Setting and Using the Controller

The controller must be set up correctly for the appliance to perform properly.

Note: Ensure that the bottom of the controller is firmly locked onto the four tabs on the top of the drive end cap assembly. See Cabinet and Cover Assemblies diagram later in this manual.

Regenerate Button

The Regenerate button is used when starting the water filtration appliance and to start an immediate regeneration. The Regenerate button can be used in two ways:

1.The Regenerate button can be used to put the appliance into an immediate regeneration.

A.Press and hold the Regenerate button for about five seconds until the display changes to “Going to.”

B.The appliance is in regeneration mode and will display the status of each cycle. After all regeneration cycles are complete, the display will return to normal operating mode.

2.The Regenerate button can be used to quickly advance through all of the regeneration cycles to speed up the cycles, which is used when starting up or diagnosing the appliance only.

A.To advance through the regeneration cycles, press and hold the Regenerate button for about five seconds until the display changes to “Going to.”

B.The cycle position will display (for example, Backwash 1).

C.Each cycle can be advanced by pressing the Regenerate button. Always wait until the cycle position displays before advancing to the next cycle position.

Figure 4: Regenerate Button

WaterMax 60 Series Owner’s Manual

11/10/2008

14

Image 14
Contents Series Year Limited Warranty Number Owner Pays forContents General Information For Owner’s ReferenceGetting Maximum Efficiency From the Appliance Six-Button ControllerSix-Button Controller, Controller Part FunctionSet Regeneration Time Customer SettingsSet Time of Day Set Number of PeopleChecklist Before Installation Iron Type DescriptionPrecautions Do NotInstallation Steps and Start-Up Procedures Prepare the Placement AreaInstallation Steps and Start-Up Procedures, Plug in the Transformer Set Up the ControllerCheck for Leaks Add Water to the Brine TankComplete the Installation Bypass ValveRegenerate Button Setting and Using the ControllerBlending Valve Service Settings Meaning Possible Values CommentsService Settings, Display Meaning Possible Values CommentsSee 72-96 Hour Mode 1-Timer Mode Operating ModesMode 1 Timer Mode Setting Chart 62AKQMode 2 Demand Delayed Mode Setting Chart NA, See Mode 1 Setting ChartSalt Depths Modes 1Tools and Materials Needed 62AJQ Replenishment ProcedureReplenishment Procedure Refill Tank With Water 62AJQ Replenishment Procedure,Add Replenishment Media Replace Fill PlugDetermine Monthly Usage 61AAN WaterMax Iron Filter Sizing FormulaRegeneration Cycle Frequency Worksheet Water ExampleIron Filter and Potassium Feeder Installation Guide Iron Filter and Potassium Feeder PlacementStart-Up Procedures for 4-oz Potassium Permanganate Feeder Incorrect Correct Assembly and PartsCabinet and Cover Assemblies Assembly and Parts, Brine Tank AssemblyCabinet and Assemblies Description QuantityInjector Assembly Injector Assembly93223 Injector 93810 InjectorScreen ThroatBypass Assembly Bypass AssemblySensor Wire HousingPiston Assembly AssemblyDrive End Cap Assembly Drive End Cap AssemblyDrive Motor Valve Housing90217 93238 Drive GearBrine Valve Housing Assembly Concave side Static O-RingFlow Control Brine90843 0.5 gpm End CapRetainer Drain End Cap AssemblyH2086 Drain Line Safety Shutoff Assembly Safety Shutoff AssemblySafety Shutoff Valve Elbow Installation Safety Shutoff Valve Elbow InstallationFill Plug Assembly Fill PlugTroubleshooting Problem Possible Cause SolutionTroubleshooting, Number or Letter Reading Model NumbersEfficiency Statements Letter Media Type62AMQ1 62APQ1 WaterMax Water Conditioner SpecificationsSeries 63MAQ1 63BEQ1,2 63MXQ1 62AJQ3WaterMax Filter Specifications Filter PurposeCertificates Certificates, Certificates, Page Page Series