Service Settings, Cont.
Display |
| Meaning | Possible Values | Comments |
| A way to force regeneration at | No (or Yes, for iron) | See | |
Regeneration | No |
| Regeneration that follows. | |
|
|
|
| Displays only when in |
|
|
|
| Modes 2 or 3 |
Distiller/RO | No | Indicates if a distiller or reverse | No (or Yes if a distiller or | Displays only when in |
|
| osmosis appliance is plumbed to use | reverse osmosis appliance | Mode 2 |
|
| filtered water from the appliance | is used) |
|
Backwash 1 | 01.0 | Number of minutes the first backwash | 00.0 to 99.9 | Set to the nearest tenth of |
|
| cycle lasts |
| a minute |
Brine/Rinse | 30.0 | Number of minutes the first brine and | 00.0 to 99.9 | Set to the nearest tenth of |
|
| slow rinse cycle lasts |
| a minute |
Backwash 2 | 05.0 | Number of minutes the second | 00.0 to 99.9 | Set to the nearest tenth of |
|
| backwash cycle lasts |
| a minute |
Salt per |
| Amount of salt set to be used in each | 00.0 to 99.9 lb (kg) | Set to the nearest tenth |
Regen lbs. | 06.2 | regeneration to achieve the capacity |
|
|
|
| setting |
|
|
Turbine Pulses |
| Used by qualified personnel for | Normal |
|
Normal |
| diagnostic purposes | Test Mode |
|
Regenerate |
| Sets the appliance to regenerate | No or Yes | If set to Yes, it will force a |
Tonight | Yes | tonight |
| regeneration at the next |
|
|
|
| set regeneration time |
|
|
|
| (such as 02:00 AM). After |
|
|
|
| the regeneration, the value |
|
|
|
| will be set to No. |
|
|
|
| Displays only when in |
|
|
|
| Modes 1 or 2 |
WaterMax 60 Series Owner’s Manual | 11/10/2008 | 17 |