Hague Quality Water Intl 60 SERIES manual Mode 2 Demand Delayed Mode Setting Chart

Page 20

Service Settings, Cont.

Mode 2 (Demand Delayed Mode) Setting Chart

This section provides guidance for using different service settings to achieve the desired capacity. Note: Mode 2 and Mode 3 have the same settings. Mode 3 is NOT recommended for residential use.

 

60 Series

63MAQ1

63BEQ1,2

63MXQ1

63MDQ3

62AMQ1

62APQ1,3,4

62AKQ3

62AJQ3,5

 

Mode 2

Yes

Yes

Yes

No

Yes

No

No

No

 

Capacity

As

As

As

As

 

required

required

required

required

 

 

 

 

 

 

 

96 hour regeneration

Yes or No

Yes or No

Yes or No

Yes or No

 

(if iron present—yes)6

 

 

 

 

 

 

 

 

 

 

#1 Salt Setting

 

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

16

26

 

Brine/Rinse (minutes)

7

7

7

7

 

Backwash 2 (minutes)

3

3

3

2

 

Capacity (grains) @

5,900 @

5,900 @

8,400 @

5,200 @

 

salt (lb)

1.1 lb

1.1 lb

1.6 lb

1 lb

 

 

 

 

 

 

#2 Salt Setting

 

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

16

26

 

Brine/Rinse (minutes)

12

12

19

12

 

Backwash 2 (minutes)

3

3

3

2

 

Capacity (grains) @

16,300 @

16,300 @

20,000 @

11,900 @

 

salt (lb)

3.2 lb

3.2 lb

4.2 lb

2.7 lb

 

 

 

 

 

 

#3 Salt Setting

 

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

17

27

 

Brine/Rinse (minutes)

30

30

47

30

 

Backwash 2 (minutes)

3

3

3

2

 

Capacity (grains) @

26,700 @

26,700 @

38,700 @

23,100 @

 

salt (lb)

6.2 lb

6.2 lb

9.6 lb

6.2 lb

 

 

 

 

 

 

#4 Salt Setting8

 

 

 

 

 

 

 

 

 

Backwash 1 (minutes)

1

1

17

47

 

Brine/Rinse (minutes)

45

45

60

45

 

Backwash 2 (minutes)

3

3

3

2

 

Capacity (grains) @

32,500 @

32,500 @

49,300 @

30,000 @

 

salt (lb)

9.5 lb

9.5 lb

14.4 lb

9.3 lb

 

 

 

 

 

1Models 63MAQ, 63BEQ, 63MXQ, 62AMQ and 62APQ are certified by WQA. All other models are not tested or certified by WQA

2Municipally supplied chlorinated water only.

3NA, See Mode 1 Setting Chart.

4Model has no backwash flow control button or retainer. Must have a minimum of 7 gpm @ 30 psi available for proper backwash. See Mode 1 Setting Chart.

5Calcite will add additional hardness to water before softening.

6If iron is present in water supply, use salt setting #3 or #4.

7If iron is present in the water supply, set Backwash 1 to 7 minutes.

8Do not use this salt setting in California.

WaterMax 60 Series Owner’s Manual

11/10/2008

20

Image 20
Contents Series Year Limited Warranty Number Owner Pays forContents General Information For Owner’s ReferenceGetting Maximum Efficiency From the Appliance Six-Button ControllerSix-Button Controller, Controller Part FunctionCustomer Settings Set Time of DaySet Regeneration Time Set Number of PeopleChecklist Before Installation Iron Type DescriptionPrecautions Do NotInstallation Steps and Start-Up Procedures Prepare the Placement AreaInstallation Steps and Start-Up Procedures, Set Up the Controller Check for LeaksPlug in the Transformer Add Water to the Brine TankComplete the Installation Bypass ValveRegenerate Button Setting and Using the ControllerBlending Valve Service Settings Meaning Possible Values CommentsService Settings, Display Meaning Possible Values CommentsSee 72-96 Hour Mode 1-Timer Mode Operating ModesMode 1 Timer Mode Setting Chart 62AKQMode 2 Demand Delayed Mode Setting Chart NA, See Mode 1 Setting ChartSalt Depths Modes 1Tools and Materials Needed 62AJQ Replenishment ProcedureReplenishment Procedure 62AJQ Replenishment Procedure, Add Replenishment MediaRefill Tank With Water Replace Fill Plug61AAN WaterMax Iron Filter Sizing Formula Regeneration Cycle Frequency WorksheetDetermine Monthly Usage Water ExampleIron Filter and Potassium Feeder Installation Guide Iron Filter and Potassium Feeder PlacementStart-Up Procedures for 4-oz Potassium Permanganate Feeder Incorrect Correct Assembly and PartsCabinet and Cover Assemblies Assembly and Parts, Brine Tank AssemblyCabinet and Assemblies Description QuantityInjector Assembly Injector Assembly93810 Injector Screen93223 Injector ThroatBypass Assembly Bypass AssemblyHousing Piston AssemblySensor Wire AssemblyDrive End Cap Assembly Drive End Cap AssemblyValve Housing 90217Drive Motor 93238 Drive GearBrine Valve Housing Assembly Concave side Static O-RingBrine 90843 0.5 gpmFlow Control End CapRetainer Drain End Cap AssemblyH2086 Drain Line Safety Shutoff Assembly Safety Shutoff AssemblySafety Shutoff Valve Elbow Installation Safety Shutoff Valve Elbow InstallationFill Plug Assembly Fill PlugTroubleshooting Problem Possible Cause SolutionTroubleshooting, Reading Model Numbers Efficiency StatementsNumber or Letter Letter Media TypeWaterMax Water Conditioner Specifications Series 63MAQ1 63BEQ1,2 63MXQ162AMQ1 62APQ1 62AJQ3WaterMax Filter Specifications Filter PurposeCertificates Certificates, Certificates, Page Page Series