Hague Quality Water Intl 60 SERIES manual Service Settings, Meaning Possible Values Comments

Page 15

Service Settings

To program Service settings on the 60 Series controller, press and hold the Service Settings button while “Service Settings” is displayed until “Set Language English” is displayed. The Next function becomes active on the Customer Settings/Next button. Use the Next button to step through parameters that can be set. Programming Service Settings is similar to programming Customer Settings (see Customer Settings for programming details). The values that can be set are listed below. (Metric values are in parentheses.)

Note: The Service Settings must be set before the Customer Settings.

Display

 

Meaning

Possible Values

Comments

Set Language English

Set the language of the display

Set Language English

 

 

 

 

Entrer Langue Francais

 

 

 

 

Entre La Lengua Español

 

 

 

 

Sprache Entr. Deutsch

 

 

 

 

Ambienti Lingua Italiano

 

Units

 

Units of measure

English

 

English

 

 

Metric

 

Show

 

Enables entry to the history file or

Yes

Enter history file

History

Yes

bypass of the history file

No

Bypass history file

 

(Hist)

Displays the current software

Cannot be set

Displays only when History

Soft. v. # 2.04

 

version

 

is set to Yes

Install

(Hist)

Installation date of the appliance

 

Displays only when History

Date

000000

(MMDDYY)

000000 to 999999

is set to Yes

Number of

(Hist)

Record of the number of people in

000 to 999

Displays only when History

People

000

the household

(should match Customer

is set to Yes

 

 

 

Settings)

 

Hardness

(Hist)

Record of tested water

 

Display only when History

Grains

000

characteristics

000 to 999 ppm (mg/L)

is set to Yes

Iron

(Hist)

 

 

 

ppm

000

 

000 to 999 ppm (mg/L)

 

Manganese

(Hist)

 

 

 

ppm

000

 

000 to 999 ppm (mg/L)

 

Chlorine

(Hist)

 

 

 

ppm

000

 

000 to 999 ppm (mg/L)

 

Sulfur

(Hist)

 

 

 

ppm

000

 

000 to 999 ppm (mg/L)

 

pH

(Hist)

 

00.0 to 99.9

 

00.0

 

 

Iron

(Hist)

 

Yes or No

 

Bacteria

Yes

 

 

 

 

 

 

 

Total

(Hist)

Total number of regenerations the

Cannot be reset

Displays only when History

Regens

00000

appliance has gone through

00000–99999

is set to Yes

Total

(Hist)

Total amount of water that has

Cannot be reset

Displays only when History

Gallons

00000000

passed through the appliance

00000000–99999999

is set to Yes

Model

(Hist)

Model number of the appliance

00AAA to 99ZZZ

Displays only when History

Number

00AAA

 

 

is set to Yes

Save

 

Saves history values

Yes

Displays only when History

History

Yes

 

No

is set to Yes

WaterMax 60 Series Owner’s Manual

11/10/2008

15

Image 15
Contents Series Number Owner Pays for Year Limited WarrantyContents For Owner’s Reference General InformationSix-Button Controller Getting Maximum Efficiency From the ApplianceController Part Function Six-Button Controller,Set Number of People Customer SettingsSet Time of Day Set Regeneration TimeIron Type Description Checklist Before InstallationDo Not PrecautionsPrepare the Placement Area Installation Steps and Start-Up ProceduresInstallation Steps and Start-Up Procedures, Add Water to the Brine Tank Set Up the ControllerCheck for Leaks Plug in the TransformerBypass Valve Complete the InstallationSetting and Using the Controller Blending ValveRegenerate Button Meaning Possible Values Comments Service SettingsDisplay Meaning Possible Values Comments Service Settings,See 72-96 Hour Operating Modes Mode 1-Timer Mode62AKQ Mode 1 Timer Mode Setting ChartNA, See Mode 1 Setting Chart Mode 2 Demand Delayed Mode Setting ChartModes 1 Salt Depths62AJQ Replenishment Procedure Replenishment ProcedureTools and Materials Needed Replace Fill Plug 62AJQ Replenishment Procedure,Add Replenishment Media Refill Tank With WaterWater Example 61AAN WaterMax Iron Filter Sizing FormulaRegeneration Cycle Frequency Worksheet Determine Monthly UsageIron Filter and Potassium Feeder Placement Iron Filter and Potassium Feeder Installation GuideStart-Up Procedures for 4-oz Potassium Permanganate Feeder Assembly and Parts Cabinet and Cover AssembliesIncorrect Correct Brine Tank Assembly Assembly and Parts,Description Quantity Cabinet and AssembliesInjector Assembly Injector AssemblyThroat 93810 InjectorScreen 93223 InjectorBypass Assembly Bypass AssemblyAssembly HousingPiston Assembly Sensor WireDrive End Cap Assembly Drive End Cap Assembly93238 Drive Gear Valve Housing90217 Drive MotorConcave side Static O-Ring Brine Valve Housing AssemblyEnd Cap Brine90843 0.5 gpm Flow ControlDrain End Cap Assembly H2086 Drain LineRetainer Safety Shutoff Assembly Safety Shutoff AssemblySafety Shutoff Valve Elbow Installation Safety Shutoff Valve Elbow InstallationFill Plug Fill Plug AssemblyProblem Possible Cause Solution TroubleshootingTroubleshooting, Letter Media Type Reading Model NumbersEfficiency Statements Number or Letter62AJQ3 WaterMax Water Conditioner SpecificationsSeries 63MAQ1 63BEQ1,2 63MXQ1 62AMQ1 62APQ1Filter Purpose WaterMax Filter SpecificationsCertificates Certificates, Certificates, Page Page Series