Hague Quality Water Intl 60 SERIES Start-Up Procedures for 4-oz Potassium Permanganate Feeder

Page 26

Start-Up Procedures for 4-oz Potassium Permanganate Feeder

Step 1 Unpack Feeder

A.Remove feeder from shipping carton.

B.Read the instructions in red, remove the label from the feeder, and discard it into the shipping carton.

C.See Figure 6 for feeder placement.

D.Remove the cover and set aside.

E.Pull up on the brine well cap to remove the safety shutoff assembly. Remove the rubber band from the air check/draw tube float rod assembly and replace the safety shutoff back into the brine well.

F.Remove the plastic bag containing the three stainless steel screws and the 3/8" tubing.

Step 2 Connect Lines

A.Connect the 3/8" tubing to the brine valve on the filter by pushing the tube to the stop. Pull back on the tubing to install the red locking clip behind the collet.

B.Connect the tubing to the feeder.

C.Connect the overflow line.

Step 3 Add Water to Feeder

A. Add 1-1/2 gallons of treated water to the feeder. The water should cover the felt pad by at

least 1/2".

Caution: Do not use water that contains iron, manganese, or hydrogen sulfide.

Step 4 Set Air Check/Draw Tube

A. Allow the water to be drawn out of the feeder until the air check/draw tube sets and then let the feeder tank refill to the right level.

Step 5 Add Potassium Permanganate to Feeder

A.Slowly add 5 lb of potassium permanganate (KMnO4) to the feeder. Coarse granular

Potassium Permanganate is recommended for this filter appliance (P/N S031). Warning: Follow the safety instructions on the container when working with potassium permanganate. Use care when removing the cover and pouring it into the feeder.

B.Place the cover on the feeder and secure it with the three stainless steel screws.

Step 6 Regenerate Filter

A. Regenerate the iron filter immediately to charge the manganese greensand. To start a regeneration, push and hold the Regenerate button until the controller displays “Going to.”

Step 7 Complete the Installation

A.See Installation Steps and Start-Up Procedures—Step 13.

WaterMax 60 Series Owner’s Manual

11/10/2008

26

Image 26
Contents Series Year Limited Warranty Number Owner Pays forContents General Information For Owner’s ReferenceGetting Maximum Efficiency From the Appliance Six-Button ControllerSix-Button Controller, Controller Part FunctionSet Regeneration Time Customer SettingsSet Time of Day Set Number of PeopleChecklist Before Installation Iron Type DescriptionPrecautions Do NotInstallation Steps and Start-Up Procedures Prepare the Placement AreaInstallation Steps and Start-Up Procedures, Plug in the Transformer Set Up the ControllerCheck for Leaks Add Water to the Brine TankComplete the Installation Bypass ValveRegenerate Button Setting and Using the ControllerBlending Valve Service Settings Meaning Possible Values CommentsService Settings, Display Meaning Possible Values CommentsSee 72-96 Hour Mode 1-Timer Mode Operating ModesMode 1 Timer Mode Setting Chart 62AKQMode 2 Demand Delayed Mode Setting Chart NA, See Mode 1 Setting ChartSalt Depths Modes 1Tools and Materials Needed 62AJQ Replenishment ProcedureReplenishment Procedure Refill Tank With Water 62AJQ Replenishment Procedure, Add Replenishment Media Replace Fill PlugDetermine Monthly Usage 61AAN WaterMax Iron Filter Sizing FormulaRegeneration Cycle Frequency Worksheet Water ExampleIron Filter and Potassium Feeder Installation Guide Iron Filter and Potassium Feeder PlacementStart-Up Procedures for 4-oz Potassium Permanganate Feeder Incorrect Correct Assembly and PartsCabinet and Cover Assemblies Assembly and Parts, Brine Tank AssemblyCabinet and Assemblies Description QuantityInjector Assembly Injector Assembly93223 Injector 93810 InjectorScreen ThroatBypass Assembly Bypass AssemblySensor Wire HousingPiston Assembly AssemblyDrive End Cap Assembly Drive End Cap AssemblyDrive Motor Valve Housing90217 93238 Drive GearBrine Valve Housing Assembly Concave side Static O-RingFlow Control Brine90843 0.5 gpm End CapRetainer Drain End Cap AssemblyH2086 Drain Line Safety Shutoff Assembly Safety Shutoff AssemblySafety Shutoff Valve Elbow Installation Safety Shutoff Valve Elbow InstallationFill Plug Assembly Fill PlugTroubleshooting Problem Possible Cause SolutionTroubleshooting, Number or Letter Reading Model NumbersEfficiency Statements Letter Media Type62AMQ1 62APQ1 WaterMax Water Conditioner SpecificationsSeries 63MAQ1 63BEQ1,2 63MXQ1 62AJQ3WaterMax Filter Specifications Filter PurposeCertificates Certificates, Certificates, Page Page Series