Mitsubishi Electronics PE-15MYC, PE-8MYC PEH-8,10MYA-EU, CR1 Surge killer Timer Anti short cycle

Page 67
15 13

PEH-8,10MYA-EU

(SPECIAL WIRING : ANTI SHORT CYCLE TIMER., PROTECT FOR COOL AIR BLOW.

)

Power supply,

3Phase

TB1

 

380

415Volt,

50Hertz

 

L1

 

 

 

 

 

 

 

 

L2

RED

 

 

 

 

 

 

 

L3

 

PUH-8, 10MYE-EU

CIRCUIT BREAKER

 

BLUE

(FIELD SUPPLY) 100A

N

PUH-8, 10MYC1-EU

 

PE

52C

RED

 

 

RED

 

 

WHITE

WHITE

 

BLACK

BLACK

 

 

RED

 

51F2

 

 

 

F3(3.15A)

WHITE

 

 

BLACK

 

HZ2

 

 

 

49C

 

 

 

X3

X1

X2

T1

52C

 

 

 

51F2

 

 

C7

 

 

 

3

 

 

 

26

63H

 

 

D2

51C

X1

1C4 RED

2WHITE

3

MF2

BLACK

1RED

2WHITE

3

MF3

BLACK

C5

MF3 is only PUH-8,10MYC1-EU.

X1

 

TB4 (In case of PUH-8,10MYE-EU) TB5 (In case of PUH-8,10MYC1-EU)

16

GRAY

MC

 

 

 

C7

X3

51C

 

21

1

 

T1

 

17

CZ2

S4

C6

 

 

CZ2 HZ2

 

 

X3

1

 

CH

 

26

X2

 

 

D1

30

 

 

CZ

CR2

 

C6

 

 

 

 

3

 

 

52C

14

 

 

30

 

X1 X2

CZ

 

Power supply, 3Phase

TB2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

380 415Volt, 50Hertz

 

 

52F

 

 

51F

1C1 RED

 

 

RED C21

 

 

 

 

L1

RED

 

 

 

 

 

 

 

 

 

 

 

L2

WHITE

 

 

 

 

2

WHITE

MF1

WHITE

2

 

 

 

 

 

 

L3

BLACK

 

 

 

 

3

BLUE

BLUE

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PEH-8, 10MYA-EU

CIRCUIT BREAKER

 

RED

F3(3.15A)

 

 

 

 

 

 

 

 

 

 

 

 

 

(FIELD SUPPLY) 15A

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

51F1

 

 

 

 

GRAY

TB4

1

 

 

52F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1

 

 

 

 

 

 

 

SWITCH BOX

 

CZ1

HZ1

 

 

 

PE

 

4

 

 

 

 

 

 

 

(FIELD SUPPLY)

 

 

 

 

 

 

49F

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C1

 

16

 

F2

 

 

 

 

 

 

TM

 

 

 

 

 

 

DOOR

 

 

SW1

 

 

 

 

 

 

 

 

 

5

 

 

(3.15A)

 

 

 

 

(3MIN)

 

 

 

 

 

 

 

 

 

16

 

 

COOL

 

HEAT

 

 

TB3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

13

 

 

 

 

 

C3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

X3

 

 

 

 

 

 

 

 

15

13

OUTDOOR

 

 

 

 

26L

HZ1

 

 

 

C

H

 

 

 

 

 

 

 

 

 

 

Tr

 

 

SW2

 

 

 

 

 

 

C3

 

 

17

 

 

23

 

 

 

 

 

 

 

 

FZ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

WA

 

 

CZ2 HZ2

 

 

 

 

 

 

 

 

17

AC

AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TM

 

 

 

 

 

 

 

 

 

 

 

220

24V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30FZ

 

 

CR1 240V

 

TB4

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52F

 

 

CZ1

HZ1

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

FZ

 

 

 

 

 

 

 

 

FZ

 

 

 

 

 

GRAY

5

 

 

14

 

 

 

 

 

BLUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attach the accessory

 

 

 

 

 

 

 

 

 

 

 

Compressor motor

 

 

 

Fan motor (indoor)

 

 

 

Fan motor (outdoor)

 

 

 

Contactor (compressor)

 

 

 

Contactor (fan I/D)

TB1

5

 

Terminal block

 

 

 

Crankcase heater

F1

3

 

Fuse (3.15A)

 

 

 

Transformer

49F

 

 

Internal thermostat(indoor fan)

 

 

 

Internal thermostat(compressor)

 

 

 

Over current relay (compressor)

 

 

 

Over current relay(fanI/D,O/D)

 

 

 

High-pressure switch

26L

 

 

Thermostat (freeze protection)

 

 

 

Thermostat (defrost)

 

 

 

4-Way valve

 

 

 

Auxiliary relay (fan)

CZ1, 2

Auxiliary relay (compressor)

HZ1, 2

Auxiliary relay (4-way valve)

30CZ, FZ

Auxiliary relay (check)

 

 

 

Contactor (fan O/D)

 

 

 

Auxiliary relay (defrost)

 

 

 

Switch (operation mode)

 

 

 

Switch (on)

 

 

 

Thermostat (room temp.)

C1~7

Connector (C5 is PUH-8,10MYC-EU only.)

 

 

 

Timer (defrost)

CR1, 2

Surge killer

 

 

 

Timer (Anti short cycle)

1C1

 

C2

1

Remove

 

 

2

 

 

2

1

3

MF1

 

3

2

 

 

3

 

 

 

 

This circuit diagram shows connections. (If the external static Pressure is less than 30 Pa, change to connections.)

Note:1.The dotted lines show field wiring.

2.The figure in the parentheses show field supply parts. 3.Color of earth wire is yellow and green twisting. 4.Not specified color of wire is brown.

5.When PAC-204RC is used, Timer(TM)is unneccessary.

6.Specification subject to change without notice.

Caution,

1.To protect each Fan motor and Compressor from abnormal current, Over current relays <51C>, <51F1,2> are installed. Therefore, do not change factory set value of Over current relays.

Option controller connection.

Symbol

No.

Function

PAC-204RC (Option)

terminal no.

 

 

 

 

1

Power (Active)

24VAC(L)

 

2

Cooling or Heating

COMP

TB4

 

operation

 

3

Reversing valve

4WV

 

 

 

for Heating operation

 

 

4

Fan operation

FAN HI

 

5

Power (Neutral)

24VAC(N)

- 66 -

Image 67
Contents Data Book Contents For correct installation Safety for USEDo not wash the unit with water Indoor unit Complete Line UPOutdoor unit Descriptions FeaturesTypical Installation Example Mechanical Specifications10 M Y C MODEL-DESIGNATION BreakdownPE-7~20MYC Cooling only SpecificationsPEH-5,7,8MYA Heat pump PEH-10,15,20MYA Heat pump PE-7~20MYC-EU Electrical DataHeating PEH-5,7,8MYA-EUPEH-10,15,20MYA-EU Model Selection With actual examples Selection ProcedureCalculation of net capacity Efficiency CalculationCooling Capacity Standard Air Flow Capacity TablesFactor for Various Air Flow Heating Capacity Standard Air Flow PE-7MYC-EU , PEH-7MYA-EU PEH-7MYA-EU PE-8MYC-EU , PEH-8MYA-EU combined with PUH-8MYC1-EU Use for low ambient cooling parts PEH-8MYA-EUPE-8MYC-EU , PEH-8MYA-EU combined with PUH-8MYE-EU Combined with PUH-8MYE-EU PE-8MYC-EU , PEH-8MYA-EU combined with PUH-8ME-EUPE-10MYC-EU , PEH-10MYA-EU combined with PUH-10MYC1-EU PEH-10MYA-EU PE-10MYC-EU , PEH-10MYA-EU combined with PUH-10MYE-EU Combined with PUH-10MYE-EU PE-15MYC-EU 976 PEH-15MYA-EU 989 011 PE-20MYC-EU Use for low ambient cooling parts PEH-20MYA-EU PEH-20MYC-EU AIR Volume CMM Cooling Operation RangePE-8MYC-EU PE-10MYC-EU PEH-8MYA-EU PEH-10MYA-EU FAN PerformancePEH-5MYA-EU PE-7MYC-EU PEH-7MYA-EUPE-20MYC-EU PEH-20MYA-EU PE-15MYC-EU PEH-15MYA-EUPulley outside dimensions are shown below Unit mm Outdoor units Sound DataPosition mesurement Indoor unitsPEH-5 Outline DimensionsPEH-7,8 DRAINRc HOLES26 PEH-10PEH-15 28.6Flange HOLES28 PEH-20Holes 2-ø15 Ø19.053/4 PUH-5PUH-7,8,10 Upper blow HolesCable Entry 44 Holes 2-ø15 PUH-8,10 Side blowPU-15 Ø15.885/8130 Refrigerant Pipe PUH-8ø25.41 PUH-10ø28.61-1/8Holes 6-ø15 Control Cable Entry ø27 PU-20PUH-15,20 Ø28.61-1/8 Ø15.885/8Duct work is local supply PE-7MYC-EU Standard Wiring DiagramsInternal thermostat indoor fan PE-8,10MYC-EU StandardOver current relayfanI/D,O/D PE-15MYC-EU Standard TB1 PE-20MYC-EU StandardPE-7MYC-EU Special Order Anti Short Cycle Timer Internal thermostatindoor fan PE-8,10MYC-EU Special Order Anti Short Cycle TimerPE-15MYC-EU Special Order Anti Short Cycle Timer Symbol Name MC1,2 Compressor motor PE-20MYC-EU Special Order Anti Short Cycle Timer49F Internal thermostatfan O/D 23C Ambient temperaturePE-7MYC-EU Special Order LOW Ambient Cooling 52F1 Contactor fan I/DPE-8,10MYC-EU Special Order LOW Ambient Cooling Do not change factory set value of Over current relays PE-15MYC-EU Special Order LOW Ambient CoolingAuxiliary relay fanI/D PE-20MYC-EU Special Order LOW Ambient Cooling30FZ Auxiliary relay fanI/D MF2 PEH-5MYA-EU StandardOption controller connection PEH-7MYA-EU StandardThermostat defrost Way valveC1~7 PEH-8,10MYA-EU StandardCR1 Surge killer PEH-15,20MYA-EU Standard MF2 Cool Heat PEH-8,10MYA-EU CR1 Surge killer Timer Anti short cyclePEH-15,20MYA-EU Special Wiring Anti Short Cycle Timer PEH-7MYA-EU Special Order LOW Ambient Cooling CR1 Surge killer 21S4 Way valve 26D1 Thermostat defrost 26L PEH-8,10MYA-EU Special Order LOW Ambient CoolingMF2 Fan motor outdoor 52F1 Contactor fan I/D 52F2 Contactor fan O/D 52F4PEH-15,20MYA-EU Special Order LOW Ambient Cooling 63H1,2 High-pressure switch 26L1,251F1~5 PE-7,8,10MYC-EU Electrical Operation Flow ChartsPEH-5MYA-EU, PEH-7,8,10MYA-EU PE-15MYC-EU PE-20MYC-EU PEH-15,20MYA-EU PE-7,8,10,15,20MYC-EU Refrigerant SchematicsPEH-5,7,8,10,15,20MYA-EU PE-7,8,10MYC-EU PE-15,20MYC-EU Safety & Control DevicesPEH-7,8,10MYA-EU Special Order Service refYear PE-7,8,1015,20MYC-EU Physical DataIndoor AIR Circuit Enclosure and Frame PEH Series PEH-5MYA-EU PE-8MYA-EU JH527YE JH521YE 596X1415 PUH-10MYC1-EU PUH-10MYE-EU PUH-15MYC1-EU PUH-20MYC1-EU Space required around unit Indoor unit InstallationOutdoor unit Ceiling Over Service-panelOver 500 Over Service Panel PU-15 At a single installationOver Service-panel Preparation before installing Indoor unitOver Service-panel 500 Nut M10 Washer Installation of the unit Indoor unitOutdoor unit Nut WasherLifting method Duct constructionCase of Brazing type Piping connectionExtension pipe Use the attached new packing Fig Valve knobPipe assy Throw away Fig By-pass tube Flange assy Extension pipeGood example Bad example Evacuation Airtight testAdditional refrigerant charge Drain piping Arrangement such as terminal block in control box Electric wiringControl module of outdoor unit PUH-5, 8 Control module of outdoor unit PU-20 Terminal block for connection wiresPower supply wires Control module of outdoor unit PUH-7, 8Method for connecting electric wire Selection of other capacities should be Protection switch50A 60ABefore starting the Trial run Putting condition of the belt=4.5mm Flexion loadW 1.4 2.2kg Ceiling Ceiling Obstacle blocking air outlet Instructions for USECheck points for operation Outlet grillePaste Alcohol MaintenanceFingermarks Neutral Grease Adhesive IsopropylTransferring work, and construction When beginning to use air conditioner againWhen the air conditioner is not to be used for a long time Transfer of installationConseration of the noise Place for installationMaintenance and inspection Regarding electric workAt cooling, water which places to cooling piping Trouble shootingOn / OFF Start an operation HOW to Operate Option PAC-204RCDisplay section Before starting operationFor cooling Selecting operation When selecting operationRoom temperature adjustment To change room temperature For fanClock key Time settingDays timer key Timer Hold/Resume keyError Display Trouble shootingOutdoor Unit Specification GuidelinesMemo Data Book PE,PEH Mitsubishi Electric Corporation