Mitsubishi Electronics PEH-15MYA, PE-8MYC manual PE-8,10MYC-EU Special Order Anti Short Cycle Timer

Page 54

PE-8,10MYC-EU

(SPECIAL ORDER : ANTI SHORT CYCLE TIMER)

Power supply, 3Phase

TB1

 

380

415Volt, 50Hertz

 

L1

 

 

 

 

 

 

L2

RED

 

 

 

 

 

L3

 

PU-8, 10MYC1-EU

CIRCUIT BREAKER

N

BLUE

 

(FIELD SUPPLY) 100A

 

PE

52C

RED

51C

 

RED

 

 

WHITE

WHITE

 

MC

BLACK

BLACK

 

 

 

 

 

51F2

 

 

RED

1C4 RED

F3(3.15A)

WHITE

2

WHITE

 

BLACK

3

MF2

 

BLACK

 

 

1

RED

 

 

2

WHITE

 

 

3

MF3

 

 

BLACK

49C

 

C5

 

52C

51F2

63H

51C

TB5

15

GRAY

CZ2

CZ2

CH

30

CZCR2

52C

 

 

 

30

 

 

 

CZ

Power supply,

3Phase

TB1

 

380 415Volt,

50Hertz

52F

L1

 

 

RED

 

 

L2

WHITE

 

 

L3

BLACK

PE-8, 10MYC-EU CIRCUIT BREAKER

 

RED F3(3.15A)

(FIELD SUPPLY) 15A N

 

14

51F

 

RED C21

1C1 RED

2

WHITE

WHITE

2

3

BLUE

MF1

3

BLUE

51F1

 

PE

 

C1

 

4

 

49F

 

C1

 

5

 

C3

 

1

 

26L

 

C3

 

3

FZ

30FZ

 

30 FZ

BLUE

 

 

 

 

 

 

 

 

 

 

 

Compressor motor

 

 

 

Fan motor (indoor)

 

 

 

Fan motor (outdoor)

 

 

 

Contactor (compressor)

 

 

 

Contactor (fan I/D)

TB1

5

 

Terminal block

 

 

 

Crankcase heater

F1

3

 

Fuse (3.15A)

 

 

 

Transformer

49F

 

 

Internal thermostat(indoor fan)

 

 

 

Internal thermostat(compressor)

 

 

 

Over current relay (compressor)

 

 

 

Over current relay(fanI/D,O/D)

 

 

 

High-pressure switch

26L

 

 

Thermostat (freeze protection)

 

 

 

Auxiliary relay (fan)

CZ1, 2

Auxiliary relay (compressor)

30CZ, FZ

Auxiliary relay (check)

 

 

 

Switch (on)

 

 

 

Thermostat (room temp.)

C1~ 5

Connector

CR1, 2

Surge killer

TM

 

 

Timer (Anti short cycle)

Tr

AC

220

CR1 240V

52F

TB4

1

52F

 

GRAY

 

 

 

 

SWITCH BOX

 

CZ1

 

(FIELD SUPPLY)

 

 

 

 

F2

 

 

TM

(3.15A)

 

 

23WA

 

(3MIN)

 

TB3

 

15

 

 

 

 

 

15 OUTDOOR

 

SW1

 

 

 

 

AC

 

 

 

 

CZ2

 

 

 

 

TM

24V

 

 

 

 

 

 

 

 

 

TB4

 

 

 

 

 

2

 

3

 

 

14

CZ1

 

 

 

 

 

 

 

 

 

GRAY 4

FZ

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

Attach the accessory

 

1C1

 

C2

1

Remove

 

 

 

 

2

 

 

2

1

 

3

MF1

 

3

2

 

 

 

3

 

 

 

 

 

This circuit diagram shows

connections.

(If the external static Pressure is less

 

than 30 Pa, change to connections.)

 

Note:1.The dotted lines show field wiring.

2.The figure in the parentheses show field supply parts. 3.Color of earth wire is yellow and green twisting.

4.Not specified color of wire is brown.

5.When PAC-204RC is used, Timer(TM)is unneccessary. 6.Specification subject to change without notice.

Caution,

1.To protect each Fan motor and Compressor from abnormal current, Over current relays <51C>, <51F1,2> are installed. Therefore, do not change factory set value of Over current relays.

Option controller connection.

Symbol

No.

Function

PAC-204RC (Option)

terminal no.

 

 

 

 

1

Power (Active)

24VAC(L)

TB4

2

Cooling operation

COMP

3

Fan operation

FAN HI

 

4

Power (Neutral)

24VAC(N)

- 53 -

Image 54
Contents Data Book Contents Safety for USE For correct installationDo not wash the unit with water Complete Line UP Indoor unitOutdoor unit Features DescriptionsMechanical Specifications Typical Installation ExampleMODEL-DESIGNATION Breakdown 10 M Y CSpecifications PE-7~20MYC Cooling onlyPEH-5,7,8MYA Heat pump PEH-10,15,20MYA Heat pump Electrical Data PE-7~20MYC-EUPEH-5,7,8MYA-EU HeatingPEH-10,15,20MYA-EU Selection Procedure Model Selection With actual examplesEfficiency Calculation Calculation of net capacityCapacity Tables Cooling Capacity Standard Air FlowFactor for Various Air Flow Heating Capacity Standard Air Flow PE-7MYC-EU , PEH-7MYA-EU PEH-7MYA-EU PE-8MYC-EU , PEH-8MYA-EU combined with PUH-8MYC1-EU PEH-8MYA-EU Use for low ambient cooling partsPE-8MYC-EU , PEH-8MYA-EU combined with PUH-8MYE-EU PE-8MYC-EU , PEH-8MYA-EU combined with PUH-8ME-EU Combined with PUH-8MYE-EUPE-10MYC-EU , PEH-10MYA-EU combined with PUH-10MYC1-EU PEH-10MYA-EU PE-10MYC-EU , PEH-10MYA-EU combined with PUH-10MYE-EU Combined with PUH-10MYE-EU PE-15MYC-EU 976 PEH-15MYA-EU 989 011 PE-20MYC-EU Use for low ambient cooling parts PEH-20MYA-EU PEH-20MYC-EU AIR Volume CMM Operation Range CoolingPE-7MYC-EU PEH-7MYA-EU FAN PerformancePEH-5MYA-EU PE-8MYC-EU PE-10MYC-EU PEH-8MYA-EU PEH-10MYA-EUPE-15MYC-EU PEH-15MYA-EU PE-20MYC-EU PEH-20MYA-EUPulley outside dimensions are shown below Unit mm Indoor units Sound DataPosition mesurement Outdoor unitsOutline Dimensions PEH-5PEH-7,8 28.6 PEH-10PEH-15 DRAINRc HOLES26PEH-20 Flange HOLES28Holes PUH-5PUH-7,8,10 Upper blow Holes 2-ø15 Ø19.053/4Ø15.885/8130 Refrigerant Pipe PUH-8ø25.41 PUH-10ø28.61-1/8 PUH-8,10 Side blowPU-15 Cable Entry 44 Holes 2-ø15Ø28.61-1/8 Ø15.885/8 PU-20PUH-15,20 Holes 6-ø15 Control Cable Entry ø27Duct work is local supply Wiring Diagrams PE-7MYC-EU StandardPE-8,10MYC-EU Standard Internal thermostat indoor fanOver current relayfanI/D,O/D PE-15MYC-EU Standard PE-20MYC-EU Standard TB1PE-7MYC-EU Special Order Anti Short Cycle Timer PE-8,10MYC-EU Special Order Anti Short Cycle Timer Internal thermostatindoor fanPE-15MYC-EU Special Order Anti Short Cycle Timer PE-20MYC-EU Special Order Anti Short Cycle Timer Symbol Name MC1,2 Compressor motor52F1 Contactor fan I/D 23C Ambient temperaturePE-7MYC-EU Special Order LOW Ambient Cooling 49F Internal thermostatfan O/DPE-8,10MYC-EU Special Order LOW Ambient Cooling PE-15MYC-EU Special Order LOW Ambient Cooling Do not change factory set value of Over current relaysPE-20MYC-EU Special Order LOW Ambient Cooling Auxiliary relay fanI/D30FZ Auxiliary relay fanI/D PEH-5MYA-EU Standard MF2Way valve PEH-7MYA-EU StandardThermostat defrost Option controller connectionPEH-8,10MYA-EU Standard C1~7CR1 Surge killer PEH-15,20MYA-EU Standard MF2 Cool Heat CR1 Surge killer Timer Anti short cycle PEH-8,10MYA-EUPEH-15,20MYA-EU Special Wiring Anti Short Cycle Timer PEH-7MYA-EU Special Order LOW Ambient Cooling 52F1 Contactor fan I/D 52F2 Contactor fan O/D 52F4 PEH-8,10MYA-EU Special Order LOW Ambient CoolingMF2 Fan motor outdoor CR1 Surge killer 21S4 Way valve 26D1 Thermostat defrost 26L63H1,2 High-pressure switch 26L1,2 PEH-15,20MYA-EU Special Order LOW Ambient Cooling51F1~5 Electrical Operation Flow Charts PE-7,8,10MYC-EUPEH-5MYA-EU, PEH-7,8,10MYA-EU PE-15MYC-EU PE-20MYC-EU PEH-15,20MYA-EU Refrigerant Schematics PE-7,8,10,15,20MYC-EUPEH-5,7,8,10,15,20MYA-EU Safety & Control Devices PE-7,8,10MYC-EU PE-15,20MYC-EUPEH-7,8,10MYA-EU Service ref Special OrderYear Physical Data PE-7,8,1015,20MYC-EUIndoor AIR Circuit Enclosure and Frame PEH Series PEH-5MYA-EU PE-8MYA-EU JH527YE JH521YE 596X1415 PUH-10MYC1-EU PUH-10MYE-EU PUH-15MYC1-EU PUH-20MYC1-EU Installation Space required around unit Indoor unitOutdoor unit Service-panel Ceiling OverOver 500 PU-15 At a single installation Over Service PanelPreparation before installing Indoor unit Over Service-panelOver Service-panel 500 Nut Washer Installation of the unit Indoor unitOutdoor unit Nut M10 WasherDuct construction Lifting methodPiping connection Case of Brazing typeThrow away Fig By-pass tube Flange assy Extension pipe Valve knobPipe assy Extension pipe Use the attached new packing FigGood example Bad example Airtight test EvacuationAdditional refrigerant charge Drain piping Electric wiring Arrangement such as terminal block in control boxControl module of outdoor unit PUH-5, 8 Control module of outdoor unit PUH-7, 8 Terminal block for connection wiresPower supply wires Control module of outdoor unit PU-20Method for connecting electric wire 60A Protection switch50A Selection of other capacities should bePutting condition of the belt Before starting the Trial run=4.5mm Flexion loadW 1.4 2.2kg Outlet grille Instructions for USECheck points for operation Ceiling Ceiling Obstacle blocking air outletAdhesive Isopropyl MaintenanceFingermarks Neutral Grease Paste AlcoholTransfer of installation When beginning to use air conditioner againWhen the air conditioner is not to be used for a long time Transferring work, and constructionRegarding electric work Place for installationMaintenance and inspection Conseration of the noiseTrouble shooting At cooling, water which places to cooling pipingBefore starting operation HOW to Operate Option PAC-204RCDisplay section On / OFF Start an operationFor fan Selecting operation When selecting operationRoom temperature adjustment To change room temperature For coolingTimer Hold/Resume key Time settingDays timer key Clock keyTrouble shooting Error DisplaySpecification Guidelines Outdoor UnitMemo Mitsubishi Electric Corporation Data Book PE,PEH