REMOVING THE DOUBLE LINE BREAK (DLB) RELAY
AND THE COOLING FAN MOTOR
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Unplug range or disconnect power.
2.Open the oven door and remove the racks from inside the oven.
3.Pull the range away from the wall so that you can access the rear of the unit.
4.Remove the left side panel (see page
5.To remove the double line break (DLB) relay:
a)Disconnect the wire connectors from the relay terminals.
b)Remove one of the two relay mounting screws and loosen the other screw. Slide the relay out from under the loose screw and remove it from the housing.
2 Wht
Red Yel Red
Loosen Screw | Remove Screw |
6.To remove the cooling fan motor:
a)Disconnect the wire connectors from the cooling fan motor terminals.
DLB Relay
Motor
Wires
Cooling Fan Motor
b)Remove the storage drawer from the front of the unit.