WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
DOOR SWITCH (N.O.) | DOOR LATCH ASSEMBLY (N.O.) |
Refer to page
1.Unplug range or disconnect power.
2.Set the ohmmeter to the R x 1 scale.
3.Touch the ohmmeter test leads to the door switch terminals. The meter should indi- cate an open circuit (infinite).
4.Press the actuator button and the meter should indicate continuity (0 Ω).
Door Latch Switch
Door Latch Solenoid
Refer to page
1.Unplug range or disconnect power.
2.Disconnect one of the wires from the door latch assembly component under test.
3.Set the ohmmeter to the R x 1K scale.
4.To test the solenoid, touch the ohmme- ter test leads to the terminals. The meter
should indicate between 3000 and 3800
Ω.
5.To test the door latch switch:
a)Touch the ohmmeter test leads to the COM and N.O. terminals. The meter should indicate an open circuit (infinite).
b)With the ohmmeter leads connected as stated in the previous step, press the
switch actuator. The meter should in- dicate continuity (0 Ω).