Whirlpool Vent system installation instructions Installation Instructions Use and Care Guide

Page 1

Installation Instructions and

Use and Care Guide

30" (76.2 cm)

36" (91.4 cm)

42" (106.7 cm)

Retractable (Pop-up)

Downdraft Vent Systems

IMPORTANT:

Read and save these instructions.

IMPORTANT:

Installer: Leave Installation Instructions with the homeowner.

Homeowner: Keep Installation Instructions for future reference.

Save Installation Instructions for local electrical inspector's use.

Part No. 4329225/4360363

Quick Reference

Table of Contents:

Pages

2Before you start

3Electrical requirements

4Product dimensions

4Cabinet dimensions

5Countertop cutout dimensions

6Vent system requirements Interior-mounted vent motor

7 - 9 Installation steps

9Vent system requirements Exterior-mounted vent motor

10 - 11 Installation steps

12Use and Care Information

13Accessories

Image 1
Contents Installation Instructions Use and Care Guide Important Observe all governing codes and ordinances Your safety and the safety Others is very importantElectrical requirements Downdraft Vent Must be Connected with Copper Wire onlyCabinet dimensions Product dimensionsRecommended for these installations Countertop cutout dimensionsImportant Countertops with a Bullnosed front edge are not Requirements Vent systemMaximum length of vent system Determining the length of system you needCm round vent system Excessive Weight HazardRecommended standard FittingsInsert downdraft vent into countertop cutout. Two Built-in cabinet location Kird and YkirdRoof venting Built-in cabinet location8.3 cm x 35.6 cm ventRoof Installations Wall InstallationsRecommended standard fittings Model Use and Care Information CleaningOperating downdraft vent 30 76.2 cm one-piece trim Part No white Part No black Accessories36 91.4 cm one-piece trim Part No white Part No black Instructions d’installation et Avertissement Alimentation électrique Dimensions du placard Dimensions du produitModèle de 76,2 cm 30 po Conduit Longueur Fosse de fenêtreDétermination de la longueur nécessaire du système Circuit d’évacuation de conduit rond, diam ,2 cm 6 po RecommandésDécharge vers le bas Décharge par la gauche et par la droiteRisque de choc électrique AvertissementModèles Kird et Ykird Installation murale Raccords standard recommandésInstallation sur le toit Boîte de connexion Fonctionnement du système d’aspiration par le bas Information d’utilisation et entretienNettoyage Garniture monopièce de 76,2 cm 30 po AccessoiresGarniture monopièce de 91,4 cm 36 po