bracket for rear venting
d. Remove screws attaching brackets to each side of blower. Reposition brackets on blower as shown. Then reinstall screws.
WARNING
Excessive Weight Hazard
Use two or more people to move and install downdraft vent.
Failure to do so can result in back or other injury.
10. Insert downdraft vent into countertop cutout. Two
wiring box
green ground screw
conduit
e. Reinstall blower in blower box with mouth of blower pointing out open side of blower box. Secure blower to blower box with 6
NOTE: Square metal frame attached to mouth of blower must be installed for proper operation.
f. Attach metal cover from parts bag over
g. Reconnect blower wiring cable. Secure wiring cable in 2 black plastic clips inside vent base.The wiring cable must be properly secured in the 2 clips (see step b.) Reattach blower box to downdraft vent base with 4 hex nuts.
people are recommended to support the weight of the downdraft vent during lifting. Position downdraft vent so it is centered in cutout and parallel to edge of cutout. Check that downdraft vent is level vertically. Then fasten lower support legs to cabinet floor with screws.
When attaching undercounter bracket to underside of countertop, make sure that the screw length will not go through countertop when tightened.
11. Attach one undercounter bracket on front upper right corner of downdraft vent with slot over vent mounting hole and flange against countertop. Attach other bracket to left side of downdraft vent. Carefully drill starter holes through undercounter mounting brackets into underside of countertop. Insert appropriate length screws into holes and tighten brackets to countertop.
connector
12. Remove required knockout and install conduit connector. Feed the power supply cable through the conduit connector and into the wiring box. Connect the white wires together with a
microswitches behind filters.
ON/OFF button
top trim
blower control knob
filter or filters |
|
depending on | end cap |
model |
13. Turn power supply on. Push and hold for a few seconds the button on the top of the downdraft vent. Retractable section of downdraft vent will rise and blower will start. Position the top trim over the retractable section
8. Attach backdraft damper over blower box knockout with 2
9. Remove the 2
WARNING
Electrical Shock Hazard
Disconnect power before making electrical connections.
Connect ground wire to green ground screw in terminal box.
Failure to do so can result in death or electrical shock.
and snap trim into place.
14. Turn the control knob on side of vent to check the operation and speed of blower.
If blower does not operate:
•Check that filter or filters are pressed in as far as they will go.
•Check that circuit breaker is not tripped or house fuse blown.
•Disconnect power source and check that wire connections have been made correctly.
8