Whirlpool Vent system Cm round vent system, Recommended standard, Fittings

Page 7

6" (15.2 cm) round vent system

90° elbows

 

 

 

 

 

6 ft. (1.8 m)

 

 

 

 

 

 

 

 

 

 

transition

2 ft. (0.6 m)

Maximum length = 35 ft. (8.9 m)

1 - wall cap

 

=

0 ft.

 

(0 m)

8 ft. (2.4 m) straight =

8 ft.

 

(2.4 m)

2 - 90° elbows

=

10 ft.

(3 m)

Transition

 

=

4.5 ft.

(1.4 m)

Length of 6"

 

 

 

 

 

(15.2 cm) system

=

22.5 ft. (6.9 m)

Recommended standard

fittings

 

 

 

 

 

3-1/4" x 10"

 

6" (15.2 cm) to

(8.3 cm x 25.4 cm)

3-1/4" x 10"

to 6" (15.2 cm)

(8.3 cm x 25.4 cm)

= 4.5 ft. (1.4 m)

= 1 ft. (0.3 m)

3-1/4" x 10"

 

6" (15.2 cm) to

(8.3 cm x 25.4 cm)

3-1/4" x 10"

to 6" (15.2 cm)

(8.3 cm x 25.4 cm)

90° elbow =

 

90° elbow =

5 ft. (1.5 m)

 

5 ft. (1.5 m)

90° elbow =

45° elbow =

6" wall cap =

5 ft. (1.5 m)

2.3 ft. (0.8 m)

0 ft. (0 m)

over counter support arm

2. Attach the left side and right side overcounter support brackets to the downdraft. Use 1 screw with each bracket.

end cap

3. Attach the left side and right side end caps to the downdraft. Use 1 screw with each end cap.

support leg

4. Attach support legs to side of downdraft vent with 2 screws in each leg. Do not tighten screws.

WARNING

Excessive Weight Hazard

Use two or more people to move and install downdraft vent.

Failure to do so can result in back or other injury.

level

mark

6. Move support legs down against cabinet floor. Place a level against front of downdraft vent base and adjust until downdraft vent is level vertically. Use a pencil to mark the top of each leg on downdraft vent. Then mark location of support leg mounting holes on cabinet floor. Remove downdraft vent from cutout. Drill starter holes at each mounting screw location on cabinet floor. Align top of legs with pencil marks on face of downdraft vent. Tighten screws in legs.

7. Determine which direction (down, rear, left, or right) vent will need to run from blower vent when installed in cabinet.

Down venting:

Downdraft vent is shipped with blower in down venting position so no modification is required. Go to Step 8.

Left or right venting:

a. Remove 4 hex nuts that attach blower box to downdraft vent base. Remove blower box.

b. Rotate blower box 90° to left or right so that vent blower is repositioned in the direction needed.

c. Reattach blower box to downdraft vent base with 4 hex nuts.

Installation steps

1. Put on gloves and safety glasses. Place cardboard or another form of protection on top of a flat surface where you can easily assemble the downdraft vent system. Remove parts packages, downdraft vent and blower box from carton. Remove all shipping materials, tape and protective film from downdraft vent and blower box.

5. Carefully insert downdraft vent into countertop cutout. Two people are recommended to support the weight of the downdraft vent during lifting. Check that downdraft vent is parallel to side of cutout and that mounting brackets overlap countertop.

Rear venting:

a. Remove 4 hex nuts that attach blower box to downdraft vent base. Remove blower box.

b. Note how wiring cable is installed under plastic clips inside vent base. Then carefully remove wiring cable from plastic clips. Disconnect blower wiring cable.

c. Remove 6 Phillips-head screws attaching blower to blower box. Remove blower.

7

Image 7
Contents Installation Instructions Use and Care Guide Important Observe all governing codes and ordinances Your safety and the safety Others is very importantElectrical requirements Downdraft Vent Must be Connected with Copper Wire onlyCabinet dimensions Product dimensionsRecommended for these installations Countertop cutout dimensionsImportant Countertops with a Bullnosed front edge are not Determining the length of system you need Vent systemRequirements Maximum length of vent systemFittings Excessive Weight HazardCm round vent system Recommended standardInsert downdraft vent into countertop cutout. Two Built-in cabinet location8.3 cm x 35.6 cm vent Kird and YkirdBuilt-in cabinet location Roof ventingRoof Installations Wall InstallationsRecommended standard fittings Model Use and Care Information CleaningOperating downdraft vent 30 76.2 cm one-piece trim Part No white Part No black Accessories36 91.4 cm one-piece trim Part No white Part No black Instructions d’installation et Avertissement Alimentation électrique Dimensions du placard Dimensions du produitModèle de 76,2 cm 30 po Conduit Longueur Fosse de fenêtreDétermination de la longueur nécessaire du système Décharge par la gauche et par la droite RecommandésCircuit d’évacuation de conduit rond, diam ,2 cm 6 po Décharge vers le basRisque de choc électrique AvertissementModèles Kird et Ykird Installation murale Raccords standard recommandésInstallation sur le toit Boîte de connexion Fonctionnement du système d’aspiration par le bas Information d’utilisation et entretienNettoyage 91,4 cm 36 po AccessoiresGarniture monopièce de 76,2 cm 30 po Garniture monopièce de