Whirlpool Vent system Accessories, 30 76.2 cm one-piece trim Part No white Part No black

Page 13

If retractable downdraft vent does not operate after clean filters have been reinstalled:

Push the filter in as far as it will go. When the filter is removed, the microswitch behind the filter is inactivated. This safety feature stops the blower and raising

Accessories

available from your dealer

Note: Instructions are included with each kit.

mechanism until the filter is properly reinstalled.

microswitches behind filters

left metal

filter right metal filter

models with two filters

locking handles

filter microswitches behind filter

models with one filter

For model series

KIRD & YKIRD 801, 802

30" (76.2 cm) one-piece trim: Part No. 8171304 (white) Part No. 8171305 (black)

Part No. 8171306 (biscuit)

For model series

KIRD & YKIRD 861, 862

36" (91.4 cm) one-piece trim: Part No. 8171310 (white) Part No. 8171311 (black)

Part No. 8171312 (biscuit)

For model series

KIRD & YKIRD 821, 822

42" (106.7 cm) one-piece trim: Part No. 8171316 (white) Part No. 8171317 (black) Part No. 8171318 (biscuit)

For model series GZ & YGZ 7930

30" (76.2 cm) one-piece trim: Part No. 8171300 (white) Part No. 8171301 (black)

For model series

GZ & YGZ 7736

36" (91.4 cm) one-piece trim: Part No. 8171302 (white) Part No. 8171303 (black)

Part No. 4329225/4360363

Benton Harbor, Michigan 49022

© 1999 Whirlpool Corporation

Image 13
Contents Installation Instructions Use and Care Guide Important Observe all governing codes and ordinances Your safety and the safety Others is very importantElectrical requirements Downdraft Vent Must be Connected with Copper Wire onlyCabinet dimensions Product dimensionsRecommended for these installations Countertop cutout dimensionsImportant Countertops with a Bullnosed front edge are not Requirements Vent systemMaximum length of vent system Determining the length of system you needCm round vent system Excessive Weight HazardRecommended standard FittingsInsert downdraft vent into countertop cutout. Two Built-in cabinet location Kird and YkirdRoof venting Built-in cabinet location8.3 cm x 35.6 cm ventRoof Installations Wall InstallationsRecommended standard fittings Model Use and Care Information CleaningOperating downdraft vent 30 76.2 cm one-piece trim Part No white Part No black Accessories36 91.4 cm one-piece trim Part No white Part No black Instructions d’installation et Avertissement Alimentation électrique Dimensions du placard Dimensions du produitModèle de 76,2 cm 30 po Conduit Longueur Fosse de fenêtreDétermination de la longueur nécessaire du système Circuit d’évacuation de conduit rond, diam ,2 cm 6 po RecommandésDécharge vers le bas Décharge par la gauche et par la droiteRisque de choc électrique AvertissementModèles Kird et Ykird Installation murale Raccords standard recommandésInstallation sur le toit Boîte de connexion Fonctionnement du système d’aspiration par le bas Information d’utilisation et entretienNettoyage Garniture monopièce de 76,2 cm 30 po AccessoiresGarniture monopièce de 91,4 cm 36 po