Whirlpool Vent system Kird and Ykird, Built-in cabinet location, Roof venting

Page 9

15. Connect vent system to blower. Vent system must end with a wall or roof cap. Use duct tape to seal all joints.

16. Install cooktop according to manufacturer’s instructions. Check that rear of cooktop overlaps edge of retractable downdraft vent by 3/8" (9.5 mm).

To get the most efficient

use from your new

retractable downdraft vent,

read the Use and Care Information section on page 12.

Keep Installation

Instructions

and Use and Care

Information close by for

easy reference.

Exterior-mounted vent motor

KIRD and YKIRD

Built-in cabinet location

MODELS ONLY

 

 

NOTE: Exterior-mounted vent

 

 

motor installations require exterior

 

 

blower system, Part No.

 

 

KPED890T, available from your

 

 

dealer or authorized parts supplier.

 

 

 

 

 

Installation requirements

 

left vent

right vent

 

 

 

Roof venting

 

 

 

Island location

 

 

3-1/4" x 14"

Built-in cabinet location(8.3 cm x 35.6 cm) vent

Maximum length of vent system

Vent

Length

 

 

9" (22.9 cm) round

55 feet (16.8 m)

 

 

3-1/4" x 14"

55 feet (16.8 m)

(8.3 cm x 35.6 cm)

 

 

 

For best performance, use no more than three 90° elbows. If more than one elbow is used, make sure that there is a minimum of 24 inches

(61 cm) of straight vent between any two elbows. Do Not install two elbows together.

It is recommended that you use round vent instead of rectangular vent, especially if elbows are required. If rectangular vent is required, it should be transitioned to 9" (22.9 cm) round vent as soon as possible.

Determining the length of system you need:

To calculate the length of system you need, add the equivalent feet for each duct piece that will be needed. See example for 9"

(22.9 cm) round vent system.

9" (22.9 cm) round vent system

Maximum length = 55 ft. (16.8 m)

2 - 90 elbows

= 10

ft.

(3 m)

10 ft. (3 m) straight = 10

ft.

(3 m)

 

 

 

 

Length of 9"

 

 

 

(22.9 cm) system

= 20

ft. (6.1 m)

Note: The exterior-mounted vent motor requires a separate wiring cable that should be installed at the same time the vent work is installed.

9

Image 9
Contents Installation Instructions Use and Care Guide Important Observe all governing codes and ordinances Your safety and the safety Others is very importantElectrical requirements Downdraft Vent Must be Connected with Copper Wire onlyCabinet dimensions Product dimensionsCountertop cutout dimensions Recommended for these installationsImportant Countertops with a Bullnosed front edge are not Requirements Vent systemMaximum length of vent system Determining the length of system you needCm round vent system Excessive Weight HazardRecommended standard FittingsInsert downdraft vent into countertop cutout. Two Built-in cabinet location Kird and YkirdRoof venting Built-in cabinet location8.3 cm x 35.6 cm ventWall Installations Roof InstallationsRecommended standard fittings Model Cleaning Use and Care InformationOperating downdraft vent Accessories 30 76.2 cm one-piece trim Part No white Part No black36 91.4 cm one-piece trim Part No white Part No black Instructions d’installation et Avertissement Alimentation électrique Dimensions du placard Dimensions du produitModèle de 76,2 cm 30 po Fosse de fenêtre Conduit LongueurDétermination de la longueur nécessaire du système Circuit d’évacuation de conduit rond, diam ,2 cm 6 po RecommandésDécharge vers le bas Décharge par la gauche et par la droiteRisque de choc électrique AvertissementModèles Kird et Ykird Raccords standard recommandés Installation muraleInstallation sur le toit Boîte de connexion Information d’utilisation et entretien Fonctionnement du système d’aspiration par le basNettoyage Garniture monopièce de 76,2 cm 30 po AccessoiresGarniture monopièce de 91,4 cm 36 po