Whirlpool Vent system installation instructions Product dimensions, Cabinet dimensions

Page 4

Product dimensions

top trim widths 30" vent (76.2 cm) 36" vent (91.4 cm) 42" vent (106.7 cm)

8-1/4" (21 cm) retractable vent height

27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for 36" (91.4 cm) vent 39" (99.1 cm) for 42" (106.7 cm) vent

3-1/4"x 10"

(8.3 cm x 25.4 cm)

16"

(40.6 cm)

INTERNAL 16" BLOWER

(40.6 cm) MOTOR

9-3/8"

(23.8 cm)

1-7/8" (4.8 cm)

3/8" (9.5 mm)

16"

(40.6 cm)

8"

(20.3 cm)

26-1/8"

(66.4 cm)

9" (22.9 cm)

Diameter

5/8"

(15.9 mm)

2-1/8”

(54 cm)

4"

(10.2 cm)

5/8"

(15.9 mm)

8"

(20,3 cm)

16"

(40.6 cm)

EXTERIOR-MOUNTED

BLOWER MOTOR

Cabinet dimensions

A = 1/2" (12.7 mm)

min.

17-3/16"

(43.7 cm)

all cutouts are for 3-1/4" x 10"

(8.3 cm x 25.4 cm) vent system

Locate power supply junction box at lower right hand rear corner of cabinet.

4-1/8"+A

(10.5 cm)

23-9/16"

(59.8 cm)

3/8"

(9.5 mm)

centerline of cooktop cutout

See cooktop manufacturer’s instructions for cooktop cutout depth and width.

Use dimensions for vent system cutout location that applies to your installation.

17-9/16"

(44.6 cm)

Vent system cutout dimensions for internal blower models only.

Exterior mounted blower systems connect with 9" (22.9 cm) round vent. The cutout locations for this vent system will depend upon your specific installation.

4

Image 4
Contents Installation Instructions Use and Care Guide Your safety and the safety Others is very important Important Observe all governing codes and ordinancesDowndraft Vent Must be Connected with Copper Wire only Electrical requirementsProduct dimensions Cabinet dimensionsRecommended for these installations Countertop cutout dimensionsImportant Countertops with a Bullnosed front edge are not Vent system RequirementsMaximum length of vent system Determining the length of system you needExcessive Weight Hazard Cm round vent systemRecommended standard FittingsInsert downdraft vent into countertop cutout. Two Kird and Ykird Built-in cabinet locationRoof venting Built-in cabinet location8.3 cm x 35.6 cm ventRoof Installations Wall InstallationsRecommended standard fittings Model Use and Care Information CleaningOperating downdraft vent 30 76.2 cm one-piece trim Part No white Part No black Accessories36 91.4 cm one-piece trim Part No white Part No black Instructions d’installation et Avertissement Alimentation électrique Dimensions du produit Dimensions du placardModèle de 76,2 cm 30 po Conduit Longueur Fosse de fenêtreDétermination de la longueur nécessaire du système Recommandés Circuit d’évacuation de conduit rond, diam ,2 cm 6 poDécharge vers le bas Décharge par la gauche et par la droiteAvertissement Risque de choc électriqueModèles Kird et Ykird Installation murale Raccords standard recommandésInstallation sur le toit Boîte de connexion Fonctionnement du système d’aspiration par le bas Information d’utilisation et entretienNettoyage Accessoires Garniture monopièce de 76,2 cm 30 poGarniture monopièce de 91,4 cm 36 po