2.Drain the frypot.
3.Remove the screws from the upper left and right corners of the control panel. The panel is hinged at the bottom and will swing open from the top.
4.Unplug the wiring harness from the back of the controller and disconnect the grounding wire.
Unplug
harness
5. Remove the controller from the fryer by lift- ing it from the hinge slots in the control panel frame.
6.Remove the two screws from the base of the interface board mounting bracket.
7.Disconnect the
8.Remove the
9.Using a
10.Unscrew the temperature probe from the frypot and remove.
11.Apply Loctite™ PST56765 thread sealant or equivalent to new probe threads.
12.Reverse steps 1 through 10 to install the replacement probe.
1.8.4 Replacing the
1.Disconnect the fryer from the electrical supply.
2.Drain the frypot.
3.Loosen the setscrew securing the thermostat knob and remove the knob. Remove the screws from the upper left and right corners of the control panel. The control panel is hinged at the bot- tom and will swing open from the top.
4.Disconnect the
6.Disconnect the
7.Unscrew the
8.Apply Loctite™ PST56765 thread sealant or equivalent to the replacement thermostat threads.
9.Reverse steps 1 through 7 to install the replacement.