Frymaster 45 Series manual Cleaning the Gas Valve Vent Tube, Calibrating the Thermostat Control

Page 12

1.5Cleaning the Gas Valve Vent Tube

1.Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened for ease in removal.

2.Pass a piece of ordinary binding wire (.052 inch diameter) or equivalent through the tube to re- move any obstruction.

3.Remove the wire, then blow through the tube to ensure it is clear.

4.Reinstall tube and bend it so that the opening is pointing downward.

1.6Adjusting Burner Ceramic Target Spacing and Alignment

DANGER

Drain the frypot or remove the handle from the drain valve before proceeding further.

Proper spacing of the top edge of the burner ceramic targets is ¾ inch (13 mm) from the frypot side. To adjust target spacing, bend the brackets to which they are attached away or toward the frypot to the proper distance. (A length of board of the proper thickness is useful as a gauge to verify spacing and alignment.)

1.7Calibrating the Thermostat Control

NOTE: The fryer control panel must be hinged down from the control panel mounting frame to per- form thermostat calibration. In order to hinge the control panel down, the thermostat knob must be removed from its shaft. It is secured with a setscrew located opposite the index mark on the knob.

1.Fill the frypot to the lower OIL-LEVEL line with cooking oil/shortening. If solid shortening is used, it must be pre-melted before starting the calibration procedure.

2.Ensure the fryer ON/OFF Switch is in the OFF position, then light the pilot. (Refer to Chapter 3 of the 45 Series Gas Fryer Installation and Operation Manual for detailed lighting instructions.)

3.Insert a good grade thermometer or pyrometer into the frypot so that it touches the thermostat guard.

4.Loosen the setscrew and stop screw securing the ther- mostat shaft extension to the flexible shaft. Remove the extension to expose the slot in the end of the flexi- ble shaft.

5.Place the fryer ON/OFF switch in the ON position.

NOTE: If the burner does not light at this time, it does not mean the thermostat is defective!

Stop screw

Locking nut

Setscrew

Use a small flat-tipped screwdriver to slowly turn the flexible shaft counterclockwise until the burner lights. Turning the shaft counterclockwise causes the burner to light and clockwise causes it to shut off.

1-6

Image 12
Contents Hour Service Hotline Gas FryersCanada Page Series GAS Fryers Service and Parts Manual Table of Contents Parts List This page Intentionally Left Blank Functional Description Interface Boards 806-3548, 806-5490, Series Interface Board LED Diagnostic Lights Accessing Fryers for Servicing Adjusting the Pilot Flame CE Standard Burner Manifold Gas PressuresCleaning the Gas Valve Vent Tube Calibrating the Thermostat ControlDisconnect Grounding wire Replacing the Temperature Probe Unplug Harness Disconnect Grounding wire Page Disconnect fryer from electrical and gas supplies Bend clip to release thermopile Replacing the Frypot Troubleshooting and Problem Isolation Ignition Failures Improper Burner Functioning CE Standard For Incoming Gas PressuresImproper Temperature Control Computer-Related Problems Filtration Problems Sediment Particle Oil Flow Up for reverse Down for Forward Leakage Problems Basket Lift MalfunctionsBell Crank Basket Lift Simplified Schematic Manual Push-Button BINDING/JAMMING Problems Bell Crank Basket Lift Simplified Wiring Diagram Modular Basket Lift Simplified Wiring Diagram Troubleshooting Guides Interpretation of Digital Controller LightsVerify that the ON/OFF switch is in the on positon Pin 6? Xfmr Troubleshooting the Gas Valve Troubleshooting the Thermostat Troubleshooting the Temperature Probe Probe Resistance Chart Wiring Diagrams Plan Wiring DiagramPlan Wiring Diagram CE 230V MJ45 W/COMPUTER and Basket Lift Plan Wiring Diagram CE FM/MJ 45 W/0 Computer Inset A-A Plan Wiring Diagram Series Basket Lift System Plan Wiring Diagram Series Basket Lift System This page Intentionally Left Blank Series GAS Fryers Service and Parts Manual Parts List BellCrankBasket Lift PartsComponent 208-250V Configuration Modular Basket LiftMount, Modular Basket Lift Burner Assembly Component Parts Component Cabinet Assemblies and Component Parts Enameled use 902-9324SP for side with access openings MJ45 BatteriesFM45 Batteries with Built-In Filtration FM145 Filter on LeftComponent Filter Magic II Add-On Cabinet Components Side, Left Cabinet, w/Access Openings CASTERS, LEGS, and Associated Hardware Components Page Complete Shield Assemblies Complete Box Assembly This page Intentionally Left Blank Page Component Controller Assemblies Thermostat Controllers Set Screw Controller Assemblies Other than Thermostat Controllers Door Assembly DrainSystem Components Component Filter Magic II Filter Pan Assemblies ComponentFrypot Assemblies and Component Parts OIL Component Through March April 2001 and Later Power Shower Assembly Temperature PROBE, THERMOSTATS, and Related Components Wiring ASSEMBLIES/HARNESSES and Remote Cable Assemblies Wiring Assemblies and HarnessesWiring CONNECTORS, PIN TERMINALS, and Power Cords Power CordsThis page Intentionally Left Blank Service Hotline