1.10.3 Troubleshooting the Gas Valve
Verify that gasmain
street valve is open and fryer gasline cutoff valve is open.
Verify gas valve is
in ON position.
Natural
Is incoming
gas pressure ![]()
![]()
kPa)?
Is 24VAC
present at the gas
valve?
For which gas is
the fryer
configured?
Problem is with fryer gas supply.
|
| Problem is in the 24VAC |
|
| circuit. See Troubleshooting |
No |
| |
| the 24VAC Circuit on Pages | |
|
| |
|
|
Propane
Is incoming
No gas pressure
kPa)?
|
|
| Place the ON/OFF |
|
|
| |
|
|
| or POWER switch |
|
|
| |
Yes |
|
|
|
| Yes | ||
|
| in the ON position |
|
| |||
|
|
|
|
|
| ||
|
|
| and light the pilot. |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Does the pilot
remain lit?
Yes
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No |
|
|
|
|
|
|
|
| |
|
|
|
|
| Is output from |
|
|
|
|
| Probable cause is a | |||||
|
|
|
|
| the thermopile approximately |
|
|
|
|
| ||||||
|
|
|
|
| No |
|
| |||||||||
|
|
|
|
|
|
| ||||||||||
|
|
|
|
| 400 millivolts? |
|
|
| failed thermopile. | |||||||
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| Yes |
|
|
|
|
|
|
| |||
|
|
|
|
| Is continuity |
|
|
|
|
| Probable cause | |||||
Problem is a |
|
|
|
|
|
|
|
| ||||||||
| Yes |
| of the |
|
| No |
| is a failed | ||||||||
failed gas valve. |
|
|
|
|
| |||||||||||
|
|
| zero? |
|
|
|
|
| switch. | |||||||
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
| |||||||