1.10.3 Troubleshooting the Gas Valve
Verify that gasmain
street valve is open and fryer gasline cutoff valve is open.
Verify gas valve is
in ON position.
Natural
Is incoming
gas pressure
kPa)?
Is 24VAC
present at the gas
valve?
For which gas is
the fryer
configured?
Problem is with fryer gas supply.
|
| Problem is in the 24VAC |
|
| circuit. See Troubleshooting |
No |
| |
| the 24VAC Circuit on Pages | |
|
| |
|
|
Propane
Is incoming
No gas pressure
kPa)?
|
|
| Place the ON/OFF |
|
|
| |
|
|
| or POWER switch |
|
|
| |
Yes |
|
|
|
| Yes | ||
|
| in the ON position |
|
| |||
|
|
|
|
|
| ||
|
|
| and light the pilot. |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Does the pilot
remain lit?
Yes
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| No |
|
|
|
|
|
|
|
| |
|
|
|
|
| Is output from |
|
|
|
|
| Probable cause is a | |||||
|
|
|
|
| the thermopile approximately |
|
|
|
|
| ||||||
|
|
|
|
| No |
|
| |||||||||
|
|
|
|
|
|
| ||||||||||
|
|
|
|
| 400 millivolts? |
|
|
| failed thermopile. | |||||||
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| Yes |
|
|
|
|
|
|
| |||
|
|
|
|
| Is continuity |
|
|
|
|
| Probable cause | |||||
Problem is a |
|
|
|
|
|
|
|
| ||||||||
| Yes |
| of the |
|
| No |
| is a failed | ||||||||
failed gas valve. |
|
|
|
|
| |||||||||||
|
|
| zero? |
|
|
|
|
| switch. | |||||||
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|