1.10.1 Troubleshooting the 24VAC Circuit in Units without Interface Boards
Verify that the ON/OFF switch is in the ON positon.
Is 24VAC |
|
|
| Is 24VAC |
|
|
| Probable cause |
present at the gas |
| No |
| present at the ON/OFF |
| No |
| is a failed |
|
|
|
| |||||
valve? |
|
|
| switch? |
|
|
| transformer. |
|
|
|
|
|
Yes
Yes
Is the continuity |
|
|
| Probable cause |
of the ON/OFF switch OK |
|
|
| |
| No |
| is a failed ON/OFF | |
(zero resistance in the ON |
|
| ||
|
|
| switch. | |
|
|
| ||
position)? |
|
|
| |
|
|
|
|
Yes
Verify that the temperature
of the cooking oil/
shortening is at least 15
degrees below the thermostat setting.
Is continuity of |
|
|
| Probable cause is a |
the thermostat OK (zero |
| No |
| |
|
| failed thermostat. | ||
resistance)? |
|
|
| |
|
|
| ||
|
|
|
|
Problem is with the gas valve.
Refer to Troubleshooting the Gas Yes
Valve on Page