Frymaster 45 Series manual Functional Description

Page 7

45 SERIES GAS FRYERS SERVICE AND PARTS MANUAL

CHAPTER 1: SERVICE PROCEDURES

1.1Functional Description

The 45 Series fryers contain a welded steel (stainless or cold rolled) frypot that is directly heated by gas flames that are diffused evenly over its lower surface by ceramic targets.

The flames originate from orifices in a U-shaped burner manifold positioned beneath the frypot. The orifice diameters differ for natural and propane gas as indicated in the table below (see Page 2-7 for a complete list of available orifices).

45 Series Orifice Sizes (0-1999 ft/609 m)

Gas

Inches

Millimeters

Natural

0.057

1.45

Propane

0.034

0.86

Gas flow to the manifold is regulated by an electromechanical gas valve. This series of fryers is equipped with a 24-volt gas valve and all models use a pilot ignition system.

PILOT IGNITION SYSTEM

The pilot ignition system is comprised of the pilot orifice, pilot hood, and a thermopile. The pilot serves two purposes. The first is to light the burner, the second is to heat the thermopile. In opera- tion, the thermopile is in contact with the pilot flame and generates millivolts. The millivolt output passes through a normally closed high-limit switch and energizes the gas valve pilot coil, which in turn opens the pilot valve. If the pilot flame is extinguished, voltage is lost to the gas valve pilot coil and the pilot valve closes. A separate 24-volt circuit, activated by the fryer ON/OFF switch, pro- vides voltage through the thermostat or controller to the gas valve main coil, which opens the main valve. The gas valve is constructed so that the main valve will not open if the pilot valve is not open. The pilot flame must be manually lit (either with a match or with an optional built-in piezo igniter) when the fryer is first placed into operation.

 

 

ON/OFF

 

 

 

Switch

Line Voltage

 

 

 

Controlling Thermostat

 

Line Voltage

 

24 VAC

or

 

Main Coil

 

Transformer

Controller

 

 

 

 

 

 

 

 

Gas Valve

 

 

 

 

High-Limit

 

 

 

Thermostat

 

 

Pilot Coil

 

 

Thermopile

 

 

Pilot

The Pilot System

 

 

 

 

1-1

 

Image 7
Contents Gas Fryers Hour Service HotlineCanada Page Series GAS Fryers Service and Parts Manual Table of Contents Parts List This page Intentionally Left Blank Functional Description Interface Boards 806-3548, 806-5490, Series Interface Board LED Diagnostic Lights Accessing Fryers for Servicing CE Standard Burner Manifold Gas Pressures Adjusting the Pilot FlameCalibrating the Thermostat Control Cleaning the Gas Valve Vent TubeDisconnect Grounding wire Replacing the Temperature Probe Unplug Harness Disconnect Grounding wire Page Disconnect fryer from electrical and gas supplies Bend clip to release thermopile Replacing the Frypot Troubleshooting and Problem Isolation Ignition Failures CE Standard For Incoming Gas Pressures Improper Burner FunctioningImproper Temperature Control Computer-Related Problems Filtration Problems Sediment Particle Oil Flow Up for reverse Down for Forward Basket Lift Malfunctions Leakage ProblemsBell Crank Basket Lift Simplified Schematic Manual Push-Button BINDING/JAMMING Problems Bell Crank Basket Lift Simplified Wiring Diagram Modular Basket Lift Simplified Wiring Diagram Interpretation of Digital Controller Lights Troubleshooting GuidesVerify that the ON/OFF switch is in the on positon Pin 6? Xfmr Troubleshooting the Gas Valve Troubleshooting the Thermostat Troubleshooting the Temperature Probe Probe Resistance Chart Plan Wiring Diagram Wiring DiagramsPlan Wiring Diagram CE 230V MJ45 W/COMPUTER and Basket Lift Plan Wiring Diagram CE FM/MJ 45 W/0 Computer Inset A-A Plan Wiring Diagram Series Basket Lift System Plan Wiring Diagram Series Basket Lift System This page Intentionally Left Blank Series GAS Fryers Service and Parts Manual Parts List Parts BellCrankBasket LiftComponent Modular Basket Lift 208-250V ConfigurationMount, Modular Basket Lift Burner Assembly Component Parts Component Cabinet Assemblies and Component Parts MJ45 Batteries Enameled use 902-9324SP for side with access openingsFM145 Filter on Left FM45 Batteries with Built-In FiltrationComponent Filter Magic II Add-On Cabinet Components Side, Left Cabinet, w/Access Openings CASTERS, LEGS, and Associated Hardware Components Page Complete Shield Assemblies Complete Box Assembly This page Intentionally Left Blank Page Component Controller Assemblies Thermostat Controllers Set Screw Controller Assemblies Other than Thermostat Controllers Door Assembly DrainSystem Components Component Component Filter Magic II Filter Pan AssembliesFrypot Assemblies and Component Parts OIL Component Through March April 2001 and Later Power Shower Assembly Temperature PROBE, THERMOSTATS, and Related Components Wiring Assemblies and Harnesses Wiring ASSEMBLIES/HARNESSES and Remote Cable AssembliesPower Cords Wiring CONNECTORS, PIN TERMINALS, and Power CordsThis page Intentionally Left Blank Service Hotline