TROUBLE SHOOTING GUIDE
GAS OVENS
MODELS 1152 - 1153 - 1154 - 1155 - 1156 - 1157 - 1158
REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
Oven fan will not run | Incoming Power Supply | Check circuit breakers, reset if |
|
| required, call power company if needed. |
| Main Fan Switch | Check continuity between switch |
|
| terminals. |
| Control Box High Limit | Terminals are normally closed, and |
| Thermostat | open at 170°F ± 5F (76.6°C ± 2.8°C). |
| NOTE: Discontinued at | Check for over heating and reset |
| S/N 2011821 | thermostat. Test for proper |
|
| operation. If it will not reset and hold, re- |
|
| place thermostat. |
| Fuse, 1 Amp | Check, replace if necessary. |
| Fuseholder | Check, replace if necessary. |
| Transformer,Step Down | 120 VAC ± 10% should be present at |
|
| secondary of transformer. If proper |
|
| voltage is not present, check |
|
| transformer primary for proper |
|
| input. Replace as needed. |
| Oven Start Relay | Check for 120 VAC to relay coil. If |
|
| voltage is not present, trace wiring |
|
| back to power source. If voltage is |
|
| present, check to insure contact |
|
| is closing. |
| 20 Minute Time Delay | Check for 120 VAC at terminal #1 to |
|
| neutral on 20 minute Time Delay |
|
| Relay. If no voltage is present, trace |
|
| wiring back to power source. |
|
| If voltage is present at terminal #1, |
|
| check for 120 VAC at terminal #2 to |
|
| neutral. If no voltage is present, and |
|
| cool down relay contact is closed, |
|
| replace Time Delay Relay. |
| Main Fan Relay | Check for 120 VAC to coil of the Relay |
|
| if no voltage is present, trace wiring |
|
| back to 20 minute Time Delay Relay. |
|
| If voltage is present, check to insure |
|
| contacts are closing. |
| Fuse, 10 Amp | Check, replace if necessary. |
| Fuseholder | Check, replace if necessary. |
| Motor Capacitor | Check for opens, shorts, or grounds. |
| Main Fan Motor | Check for supply voltage to main fan |
|
| motor. If voltage is not present, trace |
|
| wiring back to main fan relay. Check for |
|
| opens, shorts, or grounds. |
|
| WITH POWER OFF: turn fan blade to |
|
| check for locked rotor. |
Impinger II - 1100 Series Service Manual - International | 25 |