S/N 2011383 and above Temp. Display out or inaccurate S/N 2011383 and above
STEPPER MOTOR DRIVE Conveyor will not run
WITH POWER OFF:
REFER TO PAGE 45
REFER TO PAGE 33
REFER TO PAGE 45
Conveyor Switch | Check for 120 VAC to conveyor switch. If no | |
voltage is present, trace wiring back to the oven | power source. | |
| Check conti nuity between switch terminals. | |
Conveyor Fuse 3AMP | Check, replace if necessary. (Not used on | |
| Model 1151) |
|
Fuseholder | Check, replace if necessary. |
|
Conveyor Control | Check for 120 VAC supply to primary |
|
(Stepper) Transformer | of transformer, if voltage is not |
|
| present, trace wiring back to the fuseholder. | |
| If voltage is present, check for output voltage | |
| from the transformer secondary. NOTE: This | |
| control transformer outputs (2) secondary voltages. | |
| Red Leads 29 VAC |
|
| Brown Leads 10 VAC |
|
| If BOTH secondary voltages are not |
|
| present, replace the transformer. |
|
Speed Adjustment | This is a 0 to 50k ohm, 10 turn |
|
Potentiometer | potentiometer WITH POWER OFF: remove the 3 | |
| pin potentiometer cable plug from the motor | |
| control board. With a digital multimeter, check | |
| the ohm reading across the red lead to the black | |
| lead, this reading should be 50k ohms ± 5% as | |
| the potentiometer is rotated through its | |
| 10 turn rotation. Place the meter leads | |
| on the red lead and white lead. Rotating | |
| the potentiometer slowly, from low to |
|
| high, the meter should show an even |
|
| transition from 0 to 50k ohms ± 5% |
|
| through the 10 turn rotation of the |
|
| potentiometer. There should be no dead | |
| or open spots through the 10 turns of | |
| the potentiometer. Check all three leads | |
| to ground. There should be no continuity | |
| to ground. |
|
| If any of the above checks fail, replace | |
| the potentiometer. |
|
Conveyor Motor | NOTE: if the conveyor drive motor |
|
(Stepper) Control | becomes jammed, the motor will stop | |
| turning. To reset, turn off conveyor |
|
| switch, wait 10 seconds and turn the |
|
| conveyor switch on. |
|
If the motor does not run, check for 2 to 29 VAC across the motor terminals 1 to 2 and 3 to 5 on the conveyor motor control. If voltage is not
44 | Impinger II - 1100 Series Service Manual - International |