Main fan runs after | Oven Start Relay | Contacts should open when main fan |
20 minute cool down |
| switch is turned off. |
| 20 Minute Time Delay | 120 VAC at terminal #2 should discontinue approxi |
|
| mately 20 minutes after main fan is switched off. If |
|
| the oven start relay contacts are open, and |
|
| the voltage continues at terminal #2 of the 20 minute |
|
| timer, for more than 20 mins., replace the timer. |
| Oven Fan Relay | Check to insure that the contacts are opening after |
|
| the coil is |
| 20 Minute Time Delay | NOTE: ON/OFF operation of the fan switch |
|
| will set the timer to 20 minutes. If the |
|
| timer is accidentally reset, turn off main breaker for |
|
| 15 seconds to cancel. |
No control box cooling |
| Check for main fan operation. If not operating, refer |
to “Oven Fan Will Not Run”. | Oven Start Relay | Check relay contacts. 120 VAC |
|
| should be present. |
| Cooling Fan Motor(s) | 120 VAC should be present at the fan |
|
| motor. If voltage is present, check for opens or |
|
| shorts. |
|
| WITH POWER OFF: Check for locked rotor of the |
|
| fan motor. |
No automatic control | Thermostat, Cooling | Check the cooling fan thermostat. box cooling |
Fan |
| (Thermostat closes at 120°F and opens at 100°F.) |
|
| With the cooling fan thermostat |
|
| continuity. If switch is open, replace. |
| Cooling Fan Motor(s) | 120 VAC should be present at the fan motor. If |
|
| voltage is present, check foropens or shorts. |
|
| WITH POWER OFF: Check for locked |
|
| rotor of the fan motor. |
Control box cooling fan | Thermostat, Cooling | This normally open thermostat should |
continues to run | Fan | close at 120°F (48.9°C) and reopen at |
|
| 100°F (37.8°C). |
Oven will not heat | Main Fan Motor | Check for main fan operation. If it is not |
|
| operating, refer to “Oven fan will not run”. |
| Heat Switch | With switch on, check for 120 VAC on |
| both terminals to neutral. | Replace if defective. |
| Air Pressure Switch | This normally open switch should close |
|
| when the main fan is activated. Adjust if |
|
| necessary (Refer to Section D). |
|
| Replace if defective. |
| Fuse, 3 Amp | Check, replace if necessary. |
| Fuseholder | Check, replace if necessary. |
| Temperature Control | Check for 120 VAC supply at |
|
| terminal #11 to neutral on temperature |
|
| control. If no voltage is present, trace |
|
| wiring back to 3 amp fuse. Turn the |
|
| temperature adjustment knob to |
|
| maximum temperature position and |
|
| check for 120 VAC at the load terminal |
|
| (#9) and neutral. If 120 VAC is |
|
| present and unit is not heating, refer |
|
| to “Mercury Contactor” for next check. |
|
| If 120 VAC is not present, proceed. |
| Thermocouple Probe | WITH POWER ON AND THERMOCOUPLE |
|
| LEADS ATTACHED TO THE TEMPERATURE |
|
| CONTROL BOARD: measure D. C. |
38 |
| Impinger II - 1100 Series Service Manual - International |