| TROUBLE SHOOTING GUIDE |
| |
| ELECTRIC OVENS |
| |
MODEL 1134 | 220/380 VAC | THREE PHASE | 50 HZ |
MODEL 1135 | 240/415 VAC | THREE PHASE | 50 HZ |
MODEL 1136 | 240 VAC | SINGLE PHASE | 50 HZ |
MODEL 1150 | 220/380 VAC | THREE PHASE | 50 HZ |
REFER TO PROPER SCHEMATIC FOR INDENTIFIED COMPONENTS | |||
SYMPTON | POSSIBLE CAUSE | EVALUATION |
|
Oven fan will not run | Incoming Power Supply | Check circuit breakers. Reset if required. | |
|
| Call Power Co. if needed. |
|
| Fuse, 10 Amp, Main Fan Check, replace if necessary. |
| |
| Fuseholder | Check, replace if necessary. |
|
| Fuse, 1 Amp, | Check, replace if necessary. |
|
| Transformer |
|
|
| Fuseholder | Check, replace if necessary. |
|
| Transformer, Control | 120 VAC ± 10% should be present at secondary of | |
|
| transformer. If proper voltage is not present, check | |
|
| transformer primary for proper input. Replace as | |
|
| needed. |
|
| Thermostat, High Limit, | Terminals are normally closed. If open, | |
| Oven Cavity | reset the thermostat and test for propeoperation. If it | |
|
| will not reset and hold, replace thermostat. | |
| Switch, Main | Check for continuity between switch | |
| Fan | terminals. |
|
| Relay, Oven Start | Check for continuity at relay coil, and | |
|
| visually check for pull in of contacts. | |
| 20 Minute Time Delay | Check for 120 VAC at terminals #1 to | |
|
| neutral on 20 minute Time Delay Relay. | |
|
| If no voltage is present, trace wiring | |
|
| back to power source. If voltage is | |
|
| present at terminal #1, check for 120 | |
|
| VAC at terminal #2 to neutral. If no voltage ispresent, | |
|
| and oven start relay is closed, replace Time Delay. | |
| Main Fan Relay | Check continuity to 120 VAC coil. Check | |
|
| for power to relay coil (120 VAC). Check for 220/240 | |
|
| VAC to relay terminals. |
|
| Main Fan Motor | Check for opens, shorts, or grounds. | |
|
| WITH POWER OFF: Turn fan blade to | |
|
| check for locked rotor. |
|
| Capacitor | Check for opens, shorts, or grounds. | |
No main fan cool down | 20 Minute Time Delay | Check for 120 VAC at terminal #2 to | |
|
| neutral while oven is “on”. Turn off the main fan | |
|
| switch, 120 VAC should continue to be present for 20 | |
|
| minutes. If voltage is not present for approx. 20 | |
|
| minutes, replace the timer. |
|
Impinger II - 1100 Series Service Manual - International |