a)For the GREEN, GOLD OR SILVER dot control board, place the test probe of your meter in position as indi- cated in prior note. Set the oven temperature control dial 500°F(260°C), adjust pot P6 (see Page D8 ) to achieve a temperature reading on test meter of 500°F(260°C). CCW to increase, CW to decrease.

10. Adjust Time/Temp Display Pot. “Temp Cal” for 500°F(260°C).

RED

 

POTENTIOMETER

TRANSFORMER MARKED

 

 

2.5 K OHMS

WITH GREEN,GOLD OR

 

 

 

 

SILVER DOT

BLACK

1

P 6

P 5

 

2

 

 

 

 

 

 

3

 

 

L 1 120 VAC

WHITE

 

 

 

11

 

 

 

 

L 2

+

 

 

 

10

6

P 3

 

 

 

 

9

-

7

 

 

 

 

 

 

 

 

 

LOAD

THERMOCOUPLE

 

 

 

 

TYPE J

 

 

 

 

RED

POTENTIOMETER

 

2.5 K OHM

 

1

BLACK

2

 

3

WHITE

11

 

 

10

+

P 3

 

6

 

9

-

7

THERMOCOUPLE

 

TYPE J

 

TRANSFORMER MARKED IN BLUE

L 1 120 VAC

L2

LOAD

RED

POTENTIOMETER

 

TRANSFORMER

2.5 K OHMS

 

MARKED IN RED

 

 

 

 

1

 

13

L 1 120 VAC

 

 

 

 

 

WHITE

 

 

12

 

 

BLACK

3

P 3

 

L 2

 

4

 

 

 

 

 

 

 

 

+

5

 

10

 

 

6

 

 

LOAD

 

-

7

 

 

 

 

 

 

 

 

 

 

 

THERMOCOUPLE

 

 

 

 

TYPE J

 

THIS BOARD DISCONTINUED

 

 

 

 

 

 

 

 

AT S/N 2000932

 

 

Impinger II - 1100 Series Service Manual - International

51

Image 51
Contents INTERNATIONAL SERVICE MANUALIMPINGER CONVEYOR OVENS MODEL 1100 SERIESTABLE OF CONTENTS SEQUENCE OF OPERATIONS 1104 thru the display into a temperature reading SEQUENCE OF OPERATION 1134 - 1135 - 1136 - S/N 2011383 and above SEQUENCE OF OPERATIONS 2011383 and above SEQUENCE OF OPERATIONS 1152 thru intervals to maintain desired temperature by the display into a temperature reading temperature readingSCHEMATIC SCHEMATIC SCHEMATIC 1134, 1135, 1150, S/N 2011383 AND BELOW SCHEMATIC 1134, 1135 S/N 2011383 AND ABOVE SCHEMATIC 1150 S/N 2011383 AND ABOVE SCHEMATIC 1136, S/N 2011383 AND BELOW SCHEMATIC 1136, S/N 2011383 AND ABOVE SCHEMATIC 1151 S/N 2011383 AND BELOW SCHEMATIC 1151 S/N 2011383 AND ABOVE SCHEMATIC1152 THRU 1158 S/N 2011383 AND BELOW SCHEMATIC1152 THRU 1158 S/N 2011383 AND ABOVE SCHEMATIC1152 AND 1153 S/N 2011821 AND ABOVE SCHEMATIC 1154 THRU 1158 S/N 2011821 AND ABOVE MODELS 1152 - 1153 - 1154 - 1155 - 1156 TROUBLE SHOOTING GUIDE GAS OVENSNo main fan cool down Gas Pressure Switch Burner Switchswitch. If switch is closed and voltage present on one side only, replace switchCheck for proper line voltage to Pilot lamp is on, but Power Supply Ignition ControlFlame will not stay on Flame Sensorthen the problem is usually with thetemperature Check power supply at the DC improper adjustment. Also check for wornbearings. TheInstallation and Operations Manual Power SupplyDC Gearmotor required. This should eliminate the problem. If surge in the incoming power lines. To eliminatethis condition remove power from the time/temp switch for 15 seconds, or if display stays onTROUBLE SHOOTING GUIDE ELECTRIC OVENS adjustment knob to maximum temperature position Switch, HeatAir Pressure Switch This normally open switch should close when theas follows MODEL Main fan runs after are not achieved, replace thermocouple WITH POWER OFF: To check resistance of themaintenance. Also, most of the problems for proper readings. If these readingsConveyor will not run MODEL 1151 200 VAC THREE PHASE 60 HZ TROUBLESHOOTING GUIDE ELECTRIC OVENRelay, Main Fan REFER TO PAGE REFER TO PAGE 43 Mercury Contactor Heater ElementsConveyor will not run S/N 2011383 and above REFER TO PAGE REFER TO PAGE REFER TO PAGESTEPPER MOTOR DRIVE Conveyor will not run Thermocouple Probe Power Supply 12 VAC Power Supplyyellow wires, thermo red wire and 1 white wireexperienced, such as a rolling of IMPINGER II CONVEYOR OVEN REMOVAL, INSTALLATION, AND ADJUSTMENTRELAY, DPST 1.Shut off power at main breaker TO REMOVE BLOWER MOTOR This is part of the burner blower motor assemblyTO REMOVE THE BLOWER WHEEL FOR PERIODIC CLEANING MOTOR, BURNER BLOWERAIR PRESSURE SWITCH Page Page HEATING ELEMENTS 1.Shut off power at main breaker 1.Shut off power at the main breakerSOLENOID VALVE 1.Shut off power at main breaker 5.Loosen pipe union in piping assemblyIGNITION CONTROL 1.Shut off power at main breaker 5.Loosen 4 nuts holding manifold to burner cap ORIFICE, MAIN BURNER2.Shut off gas at main line to the oven 4.Remove control compartment coversLAMP, PILOT BURNER LENS, PILOT LAMP TACH. GENERATOR 1.Turn off power at main breaker OPTICAL ENCODER ASSEMBLY1.Remove gearmotor assembly see “GEARMOTOR” Above 7.To adjust optical encoderD C MOTOR CONTROL BOARD 1.Turn off power 2.Remove conveyor 1.Turn off power and remove conveyor4.Reverse wires fastened to terminals A+ and A 5.Reverse wires fastened to terminals T1 and T2TRANSFORMER, TIME/TEMP. DISPLAY MODEL 1100 SERIES OVENS SWITCH, DISPLAY, SET OVEN TEMPERATUREOHMS SWITCH, ON/OFF TRANSFORMER, STEP DOWN/120 VAC DIP SWITCHES FOR 50 SEC. TO 30 MIN. TIMES maximum speed potrefer HALL EFFECT SENSOR - REPLACEMENT AIR PRESSURE SWITCH, BURNER OR OVEN CAVITY 10.Assemble in reverse order BURNER ALARM - REPLACEMENT4.Remove conveyor gear motor 8.Remove top control compartment braceGENERAL –1100SERIES LETTERDESCRIPTION GENERAL 1100 SERIES BLOW UP 1136,1150,1151,1160 Thru1163 Page DESCRIPTION CONTROL COMPARTMENT - FRONTMODELS 1152 THRU LETTERCONTROL COMPARTMENT – FRONT 1152-1158BLOW UP CONTROL COMPARTMENT – REAR LETTERDESCRIPTION CONTROL COMPARTMENT - REAR BLOW UP MODELS AND ABOVE CONTROL COMPARTMENT – REAR BLOW UP MODELS 1130-1136,1150,1151S/N 2011383 AND ABOVEMODELS 1160-1163S/N 2011978 AND ABOVE CONTROL COMPARTMENT – REAR LETTERDESCRIPTION Page DESCRIPTION CONTROL COMPARTMENT – REARMODELS 1152 THRU 1158 S/N 2011821 AND ABOVE LETTERPage OVEN BACK ASSEMBLY – 1100 SERIES OVEN BACK ASSEMBLY – 1100 SERIES BLOW UP GEARMOTOR ASSEMBLY – 1100 SERIES GEARMOTOR ASSEMBLY – 1100 SERIES BLOW UP CONVEYOR/DOOR – 1100 SERIES CONVEYOR/DOOR – 1100 SERIES BLOW UP This page intentionally left blank This page intentionally left blank