TROUBLESHOOTING GUIDE ELECTRIC OVEN
MODEL 1151 200 VAC THREE PHASE 60 HZ
REFER TO PROPER SCHEMATIC FOR INDENTIFIED COMPONENTS
SYMPTON | POSSIBLE CAUSE | EVALUATION |
Oven fan will not run | Incoming Power Supply | Check circuit breakers. Reset if required. |
|
| Call Power Co. if needed. |
| Fuses,10 Amp,Main Fan | Check, replace if necessary. |
| Fuseholder | Check, replace if necessary. |
| Fuses, 1 Amp, | Check, replace if necessary. |
| Transformer |
|
| Fuseholder | Check, replace if necessary. |
| Transformer, Control | 120 VAC ± 10% should be present |
|
| at secondary of transformer. If |
|
| proper voltage is not present, check |
|
| transformer primary for proper |
|
| input. Replace as needed. |
| Thermostat, High Limit, | Terminals are normally closed. If open, |
| Oven Cavity | reset the thermostat and test for proper |
| replace thermostat. | operation. If it will not reset and hold, |
|
| |
| Switch, Main | Check for continuity between switch |
| Fan | terminals. |
| Relay, Oven Start | Check for continuity at relay coil, and |
|
| visually check for pull in of contacts. |
| 20 Minute Time Delay | Check for 120 VAC at terminals #1 to |
|
| neutral on 20 minute Time Delay Relay. |
|
| If no voltage is present, trace wiring |
|
| back to power source. If voltage is |
|
| present at terminal #1, check for 120 |
|
| VAC at terminal #2 to neutral. If no voltage is |
|
| present, and Main Fan Switch is closed, replace |
|
| Time Delay. |
| Main Fan Relay | Check for 120 VAC to coil of the Relay. |
|
| If no voltage is present, trace wiring |
|
| back to 20 minute Time Delay Relay. If |
|
| voltage is present, check to insure |
|
| contacts are closing. |
| Main Fan Motor | Check for opens, shorts, or grounds. |
|
| WITH POWER OFF: Turn fan blade to |
|
| check for locked rotor. |
| Capacitor | Check for opens, shorts, or grounds. |
No main fan cool down | 20 Minute Time Delay | Check for 120 VAC at terminal #2 to |
|
| neutral while oven is “on”. Turn off the |
|
| main fan switch, 120 VAC should |
|
| continue to be present for 20 minutes. |
|
| If voltage is not present for |
|
| approximately 20 minutes, replace the |
|
| timer. |