TROUBLE SHOOTING GUIDE
ELECTRIC OVENS
MODEL 1104 | 380/220 VAC | THREE PHASE | 50 HZ |
MODEL 1105 | 415/240 VAC | THREE PHASE | 50 HZ |
MODEL 1106 | 240 VAC | SINGLE PHASE | 50 HZ |
REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS | |||
SYMPTON | POSSIBLE CAUSE | EVALUATION |
|
Oven fan will not run | Incoming Power Supply | Check circuit breakers. Reset if required. | |
|
| Call Power Co. if needed. |
|
| Fuse, 1 Amp, | Check, replace if necessary. |
|
| Fuseholder | Check, replace if necessary. |
|
| Switch, Main Fan | Check for continuity between switch terminals. | |
| Transformer, Control | 120 VAC ± 10% should be present | |
|
| at secondary of transformer. If proper voltage is not | |
|
| present, check transformer primary for proper input. | |
|
| Replace as needed. |
|
| Main Fan Relay | Check continuity to 120 VAC coil. Check | |
|
| for power to relay coil (120 VAC). Check for 220/240 | |
|
| VAC to the relay terminals. Check, replace | |
|
| if necessary. |
|
| Fuse 10 A. Main Fan | Check, replace if necessary. |
|
| Fuse Holder | Check, replace if necessary. |
|
| Main Fan Motor | Check for opens, shorts, or grounds. | |
|
| WITH POWER OFF: Turn fan blade to | |
|
| check for locked rotor. |
|
| Capacitor | Check for opens, shorts, or grounds. | |
No control box cooling |
| Check for main fan operation. If not operating, refer | |
|
| to “Oven fan will not run”. |
|
| Cooling Fan Motor | 120 VAC should be present at the fan motor. If | |
|
| voltage is present, check for opens or shorts. | |
|
| WITH POWER OFF: Check for locked rotor | |
|
| on fan motor. |
|
No main fan cool down | Cool Down Thermostat | Check cool down thermostat (thermostat | |
|
| closes at 160°F and opens at 140°F). | |
|
| Check for power (220/240 VAC) at cool down thermo | |
|
| stat. With cool down thermostat preheated, check for | |
|
| continuity. If switch is open, replace. | |
Oven will not heat | Main Fan Motor | Check for main fan operation. If it is not | |
|
| operating, refer to “Oven fan will not run”. | |
| High Limit Thermostat, | Terminals are normally closed (open at | |
|
| 190°F). If open, reset the thermostat and | |
|
| test for proper operation. If it will not reset and hold, | |
|
| then replace. |
|
34 | Impinger II - 1100 Series Service Manual - International |