Command

ASCII Command

Response

Additional description

 

(host to scaler)

(scaler to host)

 

 

 

 

 

Auto Switch Mode

 

 

 

On

10*1#

Asw 1]

Off

10*0#

Asw 0]

View setting

10#

X8) ]

Set auto switch mode on. Set auto switch mode off.

View the auto switch mode status. (0= off, 1= on).

Blue Screen

On

8*1#

Blu 1]

Off

8*0#

Blu 0]

View setting

8#

X8) ]

Set blue screen on. Set blue screen off.

View the current blue mode status (0= off, 1= on)

Auto Image

Enable

55*1#

Img 1]

Activates auto image for all inputs.

Disable

55* 0#

Img 0]

Turn auto image off.

Execute

55* 2#

Img 2]

Apply auto image to the selected

 

 

 

input.

View

55#

X8) ]

View auto image setting.

 

 

 

(0= disabled, 1= enabled).

OSD (On Screen Display) duration

Select speed

20*X9*#

Dur X9* ]

View speed

20#

X9* ]

Text label (OSD) (Input 4 only)

 

Write Name

Esc X8$NI]

Nam 4]

Read Name

Esc NI]

X8$]

PIP size

 

 

PIP size

16*X10%#

Pmd X10%]

View

16#

X10%]

PIP mode

 

 

PIP on

17*X10)#

Pip X10)]

PIP off

17*0#

Pip 0]

View

17#

X10)]

Sets the OSD duration

View the On screen display time.

Writes text X8$ for input 4. View text label for input 4

Select size of PIP window. View PIP window size.

Turn PIP mode on with PIP window from input X10).

Turn PIP mode off.

View selection status (on or off).

N When PIP is active, all controls apply to the PIP window. The main window cannot be modified while PIP window is displayed.

Swap (when PIP mode is “On”)

 

%

Tke0]

Swap content between main and

 

 

 

PIP window.

PIP mode audio follow (Audio model only)

 

 

Set

19*X10^#

Ald X10^]

Select audio follow setting in PIP

 

 

 

mode.

View

19#

X10^]

View audio follow status.

NX8) = 0 or 1

X8$

= Text label/Preset name:

Up to 16 characters

X9*

= OSD display setup:

0 to 5 seconds in 1 second steps

X10)

= PIP window input selection:

0 to 4

X10%

= PIP window size:

1 to 6 (see page 3-7)

X10^ = PIP audio setup:

1 to 6 (see page 3-7)

DVS 304 • Serial Communication 3-13

Image 53
Contents DVS Safety Instructions English PrecautionsConsignes de Sécurité Français Sicherheitsanleitungen DeutschQuick Start DVS QS-2 DVS 304 Quick Start Quick Start DVS 304, cont’dTable of Contents Table of Contents, cont’d DVS 304 Table of Contents TOC-iii TOC-iv DVS 304 Table of Contents One Introduction FeaturesAbout this Manual About the DVS 304, DVS 304 A, DVS 304 D, and DVS 304 ADDVS 304 Introduction Introduction, cont’d Options and accessoriesDVS 304Chapter2Two Tabletop/desktop placement Installation and OperationDVS 304 Installation and Operation Mounting the ScalerRack mounting a half rack device Rack mounting the DVSRack mounting the DVS 304 a Installation and Operation, cont’dExtron DVS 304 a Application diagramAudio Rear Panel FeaturesBoth H outputs are buffered and can be connected Wiring the RJ-45 Input selection buttons Front Panel FeaturesMenu navigation buttons LCD menu display and controlsMenu overview Menus, Configuration, and AdjustmentsMoving through menus by using front panel controls Main menus Start auto image Input configurationInput 2 video type Input 1 video typeInput 3 video type Input 4 video typePicture control Output configurationSync Polarity Resolution and refresh ratesOutput Signal Save memory preset Audio configuration DVS 304 a and DVS 304 AD onlyMemory preset IP configuration Input presetClear CLR memory preset Recalling a presetBlue mode Advanced configurationAuto switch mode Auto ImageEnhance mode RGB DelayOSD label Test patternChanging the input Picture-in-picture modeExit menu Resetting an InputUsing the swap feature Reset Mode Comparison/Summary Resetting the UnitSystem Reset 21 Front Panel Lockout Front Panel Lockout Executive modeMemory Presets IR 902 Infrared Remote Control23 DVS 304 devices connected to a Matrix switcher Setting up the DVS to work with a Matrix switcher24 Multiple DVS 304’s connected to a Matrix switcher DVS 304 Installation and Operation Click Remove Script Removing the Sync to Matrix ScriptThree Serial Communication Using the command/response tablesSIS Programmer’s Guide Host to-scaler and scaler to host communicationsCopyright information Password informationSerial Communication, cont’d Error responses= Space Symbol definitionsThis parameter is case sensitive = Rgbs Command/response table for SIS commands Video mute Input Aspect RatioColor Tint Available for Ntsc composite and S-Video onlyCommand/response table for SIS commands  Memory Presets input 1 to 4 Zoom ModeInput Presets for input 4 only Write/Read input preset nameRGB delay time Volume control audio models onlyAudio mute audio models only Audio gain and attenuation audio models onlySwap when PIP mode is On PIP modePIP mode audio follow Audio model only Blue ScreenGeneral Information Enhanced ModeQuery Firmware Version Query Part NumberEthernet data port Command/response table for IP control port commandsE0 *X6 TC Firmware version requestsCommunication, cont’d Command/response table for IP control port commands Communication Information requests Event ControlCommunication MailWeb browser specific IP setup commandsDVS 304 Serial X1$ CG X1 CS WX1 CS IpsX1IpgX1$ X6$X1$ EBVrbX2@ X2@ CVX2@ X5@Listing connections File erase commands DVS 304 Serial Communication Directory commandsEzfff Wzfff Reset /EraseZAP CommandsUsing the control program Installing the software from a CDControl Software for Windows Downloading the softwareSerial Communication, cont’d Using the help program Serial Communication, cont’d Four DVS 304 Ethernet Control Accessing and Using the Web ServerEthernet Control System Status Navigating the Default Web PagesStatus System Settings ConfigurationIP settings fields Ethernet Control, cont’dGateway IP Address Date/Time Settings fieldsScaler Settings Scaler SettingsPasswords PasswordsFirmware Upgrade Firmware upgradeUpload a file to the new directory File ManagementVideo/Audio breakaway DVS 304 a or DVS 304 AD only ControlUser Control Input presets input 4 only PresetsMemory presets Audio DVS 304 a only PIP SetupMenu System Menu System Default cycle menuDVS 304 Menu System Main menuDVS 304 Menu System A-3 Input Configuration menuStart Auto Image menu Audio Configuration menu Output Configuration menuMemory Preset menu Menu System, cont’dDVS 304 Menu System A-5 IP Configuration menuAdvanced Configuration menu Enable Executive Mode Executive Mode menuBAppendix Reference Material SpecificationsAudio input DVS 304 A, DVS 304 AD Audio DVS 304 A, DVS 304 ADAudio output DVS 304 A, DVS 304 AD Control/remote decoder/scalerGeneral Reference Material, cont’dAccessories Part Numbers and AccessoriesAccessories Part number Included partsFigure B-1 Installation of the SDI card Serial Digital Interface SDI Card InstallationDVS 304 Reference Material Reference Material, cont’d Extron’s Warranty Extron USA West