Extron electronic manual User Control, Video/Audio breakaway DVS 304 a or DVS 304 AD only

Page 78

Ethernet Control, cont’d

Control

The Control tab provides online access to DVS 304 unique features such as remote control of the front panel, memory and input presets, and picture in picture (PIP) setup.

User Control page

The User Control page (figure 4-8) simulates elements of the DVS 304 front panel, but also includes other features such as picture control, mute and freeze options, auto image, film mode, aspect ratio and front panel lockout (executive mode).

Figure 4-8 — User Control page

The aspects of each input (1-4) can be controlled independently. Click on the appropriate input number to immediately change its onscreen attributes.

Video/Audio breakaway (DVS 304 A or DVS 304 AD only)

Use the check boxes shown below to select whether video, audio or both are switched to the new selected input. When only one box is checked and the other is cleared (i.e., different audio and video sources are selected), this is a breakaway.

You can also define the volume level, mute audio, and set the level of gain and attenuation for each input (-15dB to +9dB), as shown below.

4-10 DVS 304 • Ethernet Control

Image 78
Contents DVS Consignes de Sécurité Français PrecautionsSafety Instructions English Sicherheitsanleitungen DeutschQuick Start DVS Quick Start DVS 304, cont’d QS-2 DVS 304 Quick StartTable of Contents Table of Contents, cont’d DVS 304 Table of Contents TOC-iii TOC-iv DVS 304 Table of Contents One About this Manual FeaturesIntroduction About the DVS 304, DVS 304 A, DVS 304 D, and DVS 304 ADDVS 304 Introduction Options and accessories Introduction, cont’dDVS 304Chapter2Two DVS 304 Installation and Operation Installation and OperationTabletop/desktop placement Mounting the ScalerRack mounting the DVS Rack mounting a half rack deviceInstallation and Operation, cont’d Rack mounting the DVS 304 aApplication diagram Extron DVS 304 aRear Panel Features AudioBoth H outputs are buffered and can be connected Wiring the RJ-45 Menu navigation buttons Front Panel FeaturesInput selection buttons LCD menu display and controlsMenus, Configuration, and Adjustments Moving through menus by using front panel controlsMenu overview Main menus Input configuration Start auto imageInput 3 video type Input 1 video typeInput 2 video type Input 4 video typeOutput configuration Picture controlResolution and refresh rates Output SignalSync Polarity Audio configuration DVS 304 a and DVS 304 AD only Memory presetSave memory preset Clear CLR memory preset Input presetIP configuration Recalling a presetAuto switch mode Advanced configurationBlue mode Auto ImageOSD label RGB DelayEnhance mode Test patternPicture-in-picture mode Changing the inputResetting an Input Using the swap featureExit menu Resetting the Unit System ResetReset Mode Comparison/Summary Front Panel Lockout Executive mode 21 Front Panel LockoutIR 902 Infrared Remote Control Memory PresetsSetting up the DVS to work with a Matrix switcher 23 DVS 304 devices connected to a Matrix switcher24 Multiple DVS 304’s connected to a Matrix switcher DVS 304 Installation and Operation Removing the Sync to Matrix Script Click Remove ScriptThree SIS Programmer’s Guide Using the command/response tablesSerial Communication Host to-scaler and scaler to host communicationsPassword information Copyright informationError responses Serial Communication, cont’dSymbol definitions = SpaceThis parameter is case sensitive = Rgbs Command/response table for SIS commands Color Input Aspect RatioVideo mute Tint Available for Ntsc composite and S-Video onlyCommand/response table for SIS commands  Input Presets for input 4 only Zoom ModeMemory Presets input 1 to 4 Write/Read input preset nameAudio mute audio models only Volume control audio models onlyRGB delay time Audio gain and attenuation audio models onlyPIP mode audio follow Audio model only PIP modeSwap when PIP mode is On Blue ScreenQuery Firmware Version Enhanced ModeGeneral Information Query Part NumberE0 *X6 TC Command/response table for IP control port commandsEthernet data port Firmware version requestsCommunication Information requests Command/response table for IP control port commands Communication, cont’d Event ControlMail CommunicationIP setup commands Web browser specificDVS 304 Serial IpgX1$ X1 CS WX1 CS IpsX1X1$ CG X6$X1$ EBX2@ X2@ CVVrbX2@ X5@Listing connections DVS 304 Serial Communication Directory commands File erase commandsReset /EraseZAP Commands Ezfff WzfffControl Software for Windows Installing the software from a CDUsing the control program Downloading the softwareSerial Communication, cont’d Using the help program Serial Communication, cont’d Four Accessing and Using the Web Server Ethernet ControlDVS 304 Ethernet Control Navigating the Default Web Pages StatusSystem Status IP settings fields ConfigurationSystem Settings Ethernet Control, cont’dDate/Time Settings fields Gateway IP AddressScaler Settings Scaler SettingsPasswords PasswordsFirmware upgrade Firmware UpgradeFile Management Upload a file to the new directoryControl User ControlVideo/Audio breakaway DVS 304 a or DVS 304 AD only Presets Memory presetsInput presets input 4 only PIP Setup Audio DVS 304 a onlyMenu System DVS 304 Menu System Default cycle menuMenu System Main menuInput Configuration menu Start Auto Image menuDVS 304 Menu System A-3 Memory Preset menu Output Configuration menuAudio Configuration menu Menu System, cont’dIP Configuration menu Advanced Configuration menuDVS 304 Menu System A-5 Executive Mode menu Enable Executive ModeBAppendix Specifications Reference MaterialAudio output DVS 304 A, DVS 304 AD Audio DVS 304 A, DVS 304 ADAudio input DVS 304 A, DVS 304 AD Control/remote decoder/scalerReference Material, cont’d GeneralAccessories Part number Part Numbers and AccessoriesAccessories Included partsSerial Digital Interface SDI Card Installation Figure B-1 Installation of the SDI cardDVS 304 Reference Material Reference Material, cont’d Extron’s Warranty Extron USA West