Problem | Possible Causes | What To Do |
| |
Water has air bubbles | Air in system after installation. | • Will go away after it runs for a while. |
| |
and is cloudy |
|
|
|
|
|
|
|
| |
Indicator light on faucet | Batteries installed incorrectly | • Observe orientation on page 14 and install correctly. |
| |
base not working | or expended. |
| Replace batteries if old. |
|
|
|
|
| |
| Blue light does not | • Normal operation. |
| |
| illuminate until 6 months. |
|
|
|
|
|
|
| |
| Batteries are dead. | • Use new CR2032, |
| |
|
|
| ||
Chlorine taste and/or | The ppm of chlorine in your | • If the water supply contains more than 2.0 ppm of chlorine, | ||
odor in the Reverse | water supply exceeds maximum |
| additional filtering of the water supply to the Reverse |
|
Osmosis product water | limits and has destroyed the |
| Osmosis is needed. Correct this condition before doing | |
| Reverse Osmosis membrane. |
| maintenance on the Reverse Osmosis system. |
|
|
|
|
| |
| The prefilter is no longer | • Replace the Reverse Osmosis membrane cartridge, |
| |
| removing chlorine from |
| flow control, screen, prefilter, postfilter and batteries |
|
| the water supply. |
| in the electronics box. |
|
|
|
|
|
|
Other taste and/or odor | High quality product water | • | This is normal. |
|
| may have a different taste |
|
|
|
| than what you’re used to. |
|
|
|
|
|
|
|
|
| Low water usage. | • | Completely drain system and allow to refill. |
|
|
|
|
| |
| Contamination in product | • Use sanitizing procedures. |
| |
| water storage. |
|
|
|
|
|
|
| |
| Prefilter and postfilter | • Replace the prefilter and postfilter. |
| |
| need to be changed. | • Sanitize system. |
| |
|
|
| ||
|
|
| ||
Water leaking from | Drain side of faucet air gap | • Inspect and eliminate restriction or plug. It is important | ||
faucet air gap hole | (3/8″ tubing) plugged, |
| that there are no dips, loops or low spots in the drain line | |
| restricted or incorrectly |
| from the faucet air gap to the drain pipe. Refer to |
|
| connected to the drain. |
| Installation Instructions for proper drain connection. |
|
|
|
| If drain line adapter was used as the drain point, |
|
|
|
| periodic inspection/cleaning is recommended. |
|
|
|
|
| |
System makes product | This is normal. | • Water flow rate will be lower than your regular faucet. |
| |
water slowly |
| • It takes |
| |
|
|
| ||
|
|
|
| |
| Water supply to the Reverse | • Increase water pressure, precondition the water, etc., |
| |
| Osmosis system not within |
| as needed to conform before doing maintenance on |
|
| specifications. |
| the Reverse Osmosis system. |
|
|
|
|
| |
| Prefilter cartridge plugged | • Replace the prefilter. If rate does not increase, replace |
| |
| with sediments. |
| the postfilter, Reverse Osmosis membrane cartridge, |
|
|
|
| flow control and batteries in the faucet base. |
|
|
|
|
| |
| Reverse Osmosis membrane | • Replace Reverse Osmosis membrane cartridge, flow |
| |
| plugged with sediments. |
| control and battery in the faucet base. | 21 |
|
|
|
|