APC ACRP100, ACRP501 ACCD75201 and ACCD75204 ACCD75202 and ACCD75205, ACCD75203 and ACCD75206

Page 40

ACCD75201 and ACCD75204

ACCD75202 and ACCD75205

na2449a

na2450a

ACCD75203 and ACCD75206

na2051a

Dimensions are shown in mm (in).

Note: All condensers shown on this page have eight 22 mm (0.875 in) mounting holes on their lower rails.

36

InRow RP Technical Data Manual

Image 40 Contents
InRow RP American Power Conversion Legal Disclaimer Contents InRow RP Models Overview InRow Advantages Scalable Solution for Critical EnvironmentsScalable for High Density Hot Aisle Containment System Standard Features Remote Temperature Sensors Dual Position Float Condensate ManagementNetwork Management Card Bay Kit InRow RP NetShelter SXOptional Features Microprocessor Controller Chilled Water Only Alarms AlarmsAir-cooled Only Alarms InRow RP Models Chilled Water Interior Components front of unit Chilled Water Interior Components back of unit Air-cooled Interior Components front of unit Air-cooled Interior Components back of unit Chilled Water and Air-cooled User Interface Connections BMS GNDChilled Water Electrical Panel Air-cooled Electrical Panel Performance Specifications Chilled Water Performance Specifications 5.5C 42F EWTChilled Water Performance Specifications 7.2C 45F EWT GPMChilled Water Performance Specifications 8.9C 48F EWT 29.4C DB, 18.1C WBChilled Water Performance Specifications 10C 50F EWT Chilled Water Performance Specifications 12.8C 55F EWT Chilled Water Performance Specifications 15.5C 60F EWT Chilled Water Data General Modulating ValvesGlycol Correction Factors Air-cooled Performance SpecificationsAltitude Correction Factors for InRow Products Air-cooled Data General Sound Performance Data Electrical DataDimensional Data InRow RP Assembled ModuleSX to VX Height Adapter SX to 48U SX Height AdapterChilled Water Piping Diagram Piping and Mechanical ConnectionsTop Chilled Water Piping Access top view FRONT-COLD AisleBottom Chilled Water Piping Access bottom view, looking up Air-cooled Piping Diagram Air-cooled Piping Access top Air-cooled Piping Access bottom view, looking up Air-Cooled Condensers Mechanical DataACCD75201 and ACCD75204 ACCD75202 and ACCD75205 ACCD75203 and ACCD75206ACCD75207 Air-cooled Condenser FeaturesACCD75208 and ACCD75209 Guide Specifications Part 1 GeneralVariable Speed FAN Assembly InRow RP Technical Data Manual Network Management Card Condensate Pump Selectable TOP or Bottom Piping AIR-COOLED only Guidelines for Installation Page APC Worldwide Customer Support 990-2469E-001 2009
Related manuals
Manual 82 pages 30.8 Kb