APC ACRP101, ACRP501, ACRP502, ACRP500, ACRP102, ACRP100 manual Overview

Page 5

Overview

The modular, row-based computer room cooling system offers efficient, predictable, and economical cooling for a variety of spaces.

Critical environmental requirements now reach far beyond the confines of the traditional data center or computer room to encompass a larger suite of applications, referred to as technology rooms. Critical environment applications include:

Computer rooms

Telecommunication facilities

Clean rooms

Power equipment

Medical equipment rooms

LAN/WAN environments

A worldwide network of APC representatives is fully qualified to provide engineering, sales, installation, and service for our products.

APC warrants all parts for 18 months from shipment and 12 months from startup. Extended warranties are available.

Capacity

The InRow RP chilled water configuration is available in one size with a capacity that is up to 60 kW based on the particular application of the unit. The InRow RP air-cooled configuration is available in one size with a capacity that is up to 37 kW.

Room Air Distribution

Row-based systems are placed in line with rack enclosures. At least one system is used per hot aisle. Air is drawn in through the rear of the system, cooled, and discharged into the cold aisle, thereby neutralizing the sensible heating effects of the data processing equipment.The InRow RP delivers high volumes of airflow to eliminate hot spots in densely populated environments.

Configuration

Chilled Water

Air-cooled

Compliance Approval

UL Listed

VDE

CE

C-tick

C-UL Listed

Chilled Water Standard Features

Insulated cabinet

Backward inclined impeller

Variable speed fans (3)

Shutdown input/alarm output

Chilled water flow meter

2-way/3-way floating point valve

Humidifier

Counter flow cooling coil

Electric reheat

Pleated 100 mm (4 in) filter

NPT to BSPT pipe adapters

Top or bottom piping

Condensate management with dual position float

Network management card

Baying Kit InRow RP to NetShelter® SX rack

Remote temperature sensor (3)

Microprocessor controller

Automatic transfer switch

Air-cooled Standard

Features

Insulated cabinet

Backward inclined impeller

Variable speed fans (2)

Shutdown input/alarm output

Humidifier

Cross circuited cooling coil

Electric reheat

Pleated 100 mm (4 in) filter

Pipe adapters

Top or bottom piping

Condensate management with dual position float

Network management card

Baying kit InRow RP to NetShelter® SX rack

Remote temperature sensor (3)

Microprocessor controller

Variable speed reciprocating compressor using VFD control

Liquid line solenoid valve

Pressure equalization solenoid

Accessories

Cable leak detector

Baying kit InRow RP to NetShelter VX rack

NetShelter SX 42U to 48U height adapters

NetShelter VX 42U height adapters

Bridge trough power cable shield

Data cable bridge partition

Flex hose piping kits

InRow RP Technical Data Manual

1

Image 5 Contents
InRow RP American Power Conversion Legal Disclaimer Contents InRow RP Models Overview Scalable for High Density Scalable Solution for Critical EnvironmentsInRow Advantages Hot Aisle Containment System Standard Features Dual Position Float Condensate Management Remote Temperature SensorsNetwork Management Card Bay Kit InRow RP NetShelter SXOptional Features Microprocessor Controller Air-cooled Only Alarms AlarmsChilled Water Only Alarms InRow RP Models Chilled Water Interior Components front of unit Chilled Water Interior Components back of unit Air-cooled Interior Components front of unit Air-cooled Interior Components back of unit BMS GND Chilled Water and Air-cooled User Interface ConnectionsChilled Water Electrical Panel Air-cooled Electrical Panel Chilled Water Performance Specifications 5.5C 42F EWT Performance SpecificationsGPM Chilled Water Performance Specifications 7.2C 45F EWT29.4C DB, 18.1C WB Chilled Water Performance Specifications 8.9C 48F EWTChilled Water Performance Specifications 10C 50F EWT Chilled Water Performance Specifications 12.8C 55F EWT Chilled Water Performance Specifications 15.5C 60F EWT Modulating Valves Chilled Water Data GeneralAltitude Correction Factors for InRow Products Air-cooled Performance SpecificationsGlycol Correction Factors Air-cooled Data General Electrical Data Sound Performance DataInRow RP Assembled Module Dimensional DataSX to 48U SX Height Adapter SX to VX Height AdapterPiping and Mechanical Connections Chilled Water Piping DiagramFRONT-COLD Aisle Top Chilled Water Piping Access top viewBottom Chilled Water Piping Access bottom view, looking up Air-cooled Piping Diagram Air-cooled Piping Access top Air-cooled Piping Access bottom view, looking up Mechanical Data Air-Cooled CondensersACCD75203 and ACCD75206 ACCD75201 and ACCD75204 ACCD75202 and ACCD75205ACCD75208 and ACCD75209 Air-cooled Condenser FeaturesACCD75207 Part 1 General Guide SpecificationsVariable Speed FAN Assembly InRow RP Technical Data Manual Network Management Card Condensate Pump Selectable TOP or Bottom Piping AIR-COOLED only Guidelines for Installation Page 990-2469E-001 2009 APC Worldwide Customer Support