APC ACRP101, ACRP501, ACRP502, ACRP500, ACRP102, ACRP100 manual Microprocessor Controller

Page 11

Microprocessor Controller

Status

Check

Log

Warning

Critical

Microprocessor Controller

The microprocessor controller is standard on each system. The controller provides precision control for the demanding requirements of:

Computer rooms

Telecommunication facilities

Clean rooms

Power equipment

Medical equipment rooms

LAN/WAN environments

The easy-to-use display allows the operator to select options from the device’s menu-driven interface to control and monitor the connected air conditioning system.

Open Architecture

The InRow RP protocol is open for integration with all building management systems. Communication interface on the system can be MODBUS RS485 or Ethernet.

ESC

?

Control Type

Controller utilizes proportional/ integral/derivative (PID), a time- proven precision environmental control method. This allows for custom tuning of control variables to achieve desired system response.

Functions

Supply and Return Air Conditions

Operational Mode Control

Event Logging

Alarms

Redundant Group Control

Fan Speed Adjustment

Input/Output Module Programming

Critical Alarm LED

 

 

Warning Alarm LED

 

 

Check Log LED

 

 

Status LED

 

 

Liquid Crystal Display (LCD)

 

 

Menu Selection scroll keys

 

 

Escape key

 

 

Enter key

 

 

Help key

 

 

Logging

The event log keeps a record of all alarms and events. Each event log contains a time/date stamp as well as operating conditions at the time of occurrence. The controller also displays run time, in hours, for major components (air filters, fans, and condensate pump, as well as humidifier, heater, and compressor for the air-cooled unit).

Control

The backlit, four-line by twenty- character display is password configurable.

InRow RP Technical Data Manual

7

Image 11 Contents
InRow RP American Power Conversion Legal Disclaimer Contents InRow RP Models Overview Scalable for High Density Scalable Solution for Critical EnvironmentsInRow Advantages Hot Aisle Containment System Standard Features Bay Kit InRow RP NetShelter SX Remote Temperature SensorsDual Position Float Condensate Management Network Management CardOptional Features Microprocessor Controller Air-cooled Only Alarms AlarmsChilled Water Only Alarms InRow RP Models Chilled Water Interior Components front of unit Chilled Water Interior Components back of unit Air-cooled Interior Components front of unit Air-cooled Interior Components back of unit BMS GND Chilled Water and Air-cooled User Interface ConnectionsChilled Water Electrical Panel Air-cooled Electrical Panel Chilled Water Performance Specifications 5.5C 42F EWT Performance SpecificationsGPM Chilled Water Performance Specifications 7.2C 45F EWT29.4C DB, 18.1C WB Chilled Water Performance Specifications 8.9C 48F EWTChilled Water Performance Specifications 10C 50F EWT Chilled Water Performance Specifications 12.8C 55F EWT Chilled Water Performance Specifications 15.5C 60F EWT Modulating Valves Chilled Water Data GeneralAltitude Correction Factors for InRow Products Air-cooled Performance SpecificationsGlycol Correction Factors Air-cooled Data General Electrical Data Sound Performance DataInRow RP Assembled Module Dimensional DataSX to 48U SX Height Adapter SX to VX Height AdapterPiping and Mechanical Connections Chilled Water Piping DiagramFRONT-COLD Aisle Top Chilled Water Piping Access top viewBottom Chilled Water Piping Access bottom view, looking up Air-cooled Piping Diagram Air-cooled Piping Access top Air-cooled Piping Access bottom view, looking up Mechanical Data Air-Cooled CondensersACCD75203 and ACCD75206 ACCD75201 and ACCD75204 ACCD75202 and ACCD75205ACCD75208 and ACCD75209 Air-cooled Condenser FeaturesACCD75207 Part 1 General Guide SpecificationsVariable Speed FAN Assembly InRow RP Technical Data Manual Network Management Card Condensate Pump Selectable TOP or Bottom Piping AIR-COOLED only Guidelines for Installation Page 990-2469E-001 2009 APC Worldwide Customer Support