Hoshizaki HUR68A(-D), HWR40A(-D), HUR96A(-D), HUR40A(-D) Refrigerators Energy Saving Operating Mode

Page 17

3. Refrigerators – Energy Saving Operating Mode

a) Sequence of Operation

POWER ON

Board Self Check

1. Frame heater(s) on continuously

(Q5 and earlier)

Frame heater(s) cycle on and off (Q6 and later)

2. Evaporator fan(s) cycles on and off

2-minute Delay

1.Compressor start-up

2.Condenser fan start-up

3.Frame heater(s) on (continuously)

4.Evaporator fan(s) on (continuously)

Cycle Off (Cut-out temperature reached) [Minimum 2 minutes]

1.Compressor off

2.Condenser fan off

3.Frame heater(s) cycle on and off (Q6 and later)

4.Evaporator fan(s) cycles on and off

Cycle On (Cut-on temperature reached) [Minimum 2 minutes]

1.Compressor start-up

2.Condenser fan start-up

3.Frame heater(s) on (continuously)

4.Evaporator fan(s) on (continuously)

Continue as normal cycling

Defrost Start Preprogrammed time interval

1.Compressor off

2.Frame heater(s) off (Q6 and later)

3.Evaporator fan(s) off

4.Condenser fan off

5.Defrost heater on

6."dF" displayed

Defrost End Defrost thermistor reaches defrost

termination temperature, or defrost timer reaches 1 hour

Defrost heater off

Five minutes after defrost heater off

1.Compressor on

2.Condenser fan on

Five minutes after compressor start-up

1.Evaporator fan(s) on

2.Frame heater(s)

on (Q6 and later)

One minute after evaporator fan start-up "dF" no longer displayed, cabinet temperature displayed

Note:

1)Cut-on, cut-off, and cabinet temperature are read by the same sensor, called the "cabinet thermistor."

2)The defrost thermistor reads the evaporator temperature.

17

Image 17
Contents Superior Degree Reliability Energy Star Contents Page Undercounter Model Names Specifications Nameplate RatingsDimensions HUR40A, HUF40A Units mm 1a. HUR40A-D, HUF40A-D 2a. HWR40A-D, HWF40A-D HWR40A, HWF40A3a. HUR68A-D, HUF68A-D HUR68A, HUF68A4a. HWR68A-D, HWF68A-D HWR68A, HWF68AHUR96A Units mm 5a. HUR96A-D HWR96A Units mm 6a. HWR96A-D Evaporator Case II. General Information ConstructionSequence of Operation Sequence of Operation and Timing ChartsRefrigerators Continuous Operating Mode Operating Timing ChartFreezers Continuous Operating Mode Freezers Continuous Defrost End Defrost thermistor reaches defrost Refrigerators Energy Saving Operating ModeEnergy Board Self Check Minute Delay Freezers Energy Saving Operating ModeFreezers Energy Control Board Start-Up DelayThermistor Wiring Harness K151 Relay Wiring Harness K311Rear FrontGaining Access to Settings and Diagnostics Settings and DiagnosticsAdjusting the Setpoint Temperature Temperature DisplaySwitching the Display Between Fahrenheit and Celsius F5 Cabinet Temperature Correction calibration factor Later Section Settings and Diagnostics MenuDefrost Interval F0 Defrost Termination Temperature F1Setpoint Temperature Differential F2 Low Temperature Alarm Delay Time F4 High Temperature Alarm Delay Time F3Alarm History F6 Temperature Display Scale F5Operating Modes Compressor Run Time F7Energy Saving Perimeter Frame HeaterContinuous Alarm Signals Alarm Code Problem III. Service Diagnosis Alarm CodesError Code Priority Description Alarm Display PriorityHigh Temperature Alarm E1 Alarm Details and CountermeasuresReset Options Possible CausesLow Temperature Alarm E2 High Pressure Alarm E4 Defrost Alarm E3Clogged Filter Alarm E7 Defrost Temperature Sensor Malfunction Alarm E8 Clogged Filter Sensor Malfunction Alarm E9 Control Board Error Alarms EA and ED Problem Possible Cause Remedy Diagnosis ChartProblem Possible Cause Remedy Problem Possible Cause Remedy Thermistor Check Service for Refrigerant Lines IV. Removal and Replacement of ComponentsRefrigerant Recovery BrazingEvacuation and Recharge Removal and Replacement of Compressor Removal and Replacement of Refrigeration UnitRemoval and Replacement of Evaporator Page Page Cabinet Thermistor Removal and Replacement of ThermistorsDefrost Thermistor Clogged Filter Thermistor sensorRemoval and Replacement of Defrost Heater Removal and Replacement of Door GasketRemoval and Replacement of Control Board Door Re-Hinging and Drawer Conversion Removal and Replacement of Fan MotorsCondenser Fan Motor Evaporator Fan MotorCleaning Cleaning and Maintenance InstructionsAir Filter MaintenanceShelves Drawers115/60/1 A2. HUR40A-D, HWR40A-D auxiliary code Q6 and later HUF40A-D, HWF40A-D C1. HUR68A, HWR68A auxiliary code Q5 and earlier C2. HUR68A-D, HWR68A-D auxiliary code Q6 and later HUF68A-D, HWF68A-D HUR96A-D, HWR96A-D