Hoshizaki HUR40A(-D), HWR40A(-D), HUR96A(-D), HUR68A(-D), HWR68A(-D) Clogged Filter Alarm E7

Page 38

e. Clogged Filter Alarm (E7)

The unit is equipped with a filter for protecting the condenser from dirt, oils, grease, etc. The filter promotes clean condenser surfaces and efficient operation and should be checked twice monthly and cleaned when necessary. The unit is also equipped with a sensor to determine if this filter is excessively dirty. If the unit detects that the condenser filter is excessively dirty by sensing a temperature at the condenser outlet of at least 136.4°F (58°C) for over 2 minutes, "E7" will be displayed.

Reset Options

After cleaning the filter, the alarm will automatically reset once the temperature at the condenser outlet drops below 136.4°F (58°C).

Possible Causes

The condenser air filter is dirty.

The condenser fan motor is locked or otherwise not functioning.

IMPORTANT

If this alarm occurs frequently, the compressor discharge temperature is consistently too high.

Note:

If the unit is turned off and then back on while the alarm code is displayed, the alarm may be reset even if the filter is not yet clean. However, the alarm will recur once the compressor discharge temperature reaches 136.4°F (58°C).

38

Image 38
Contents Superior Degree Reliability Energy Star Contents Page Undercounter Model Names Specifications Nameplate RatingsDimensions HUR40A, HUF40A Units mm 1a. HUR40A-D, HUF40A-D HWR40A, HWF40A 2a. HWR40A-D, HWF40A-DHUR68A, HUF68A 3a. HUR68A-D, HUF68A-DHWR68A, HWF68A 4a. HWR68A-D, HWF68A-DHUR96A Units mm 5a. HUR96A-D HWR96A Units mm 6a. HWR96A-D II. General Information Construction Evaporator CaseSequence of Operation Sequence of Operation and Timing ChartsRefrigerators Continuous Operating Mode Timing Chart OperatingFreezers Continuous Operating Mode Freezers Continuous Refrigerators Energy Saving Operating Mode Defrost End Defrost thermistor reaches defrostEnergy Freezers Energy Saving Operating Mode Board Self Check Minute DelayFreezers Energy Start-Up Delay Control BoardRear Relay Wiring Harness K311Thermistor Wiring Harness K151 FrontSettings and Diagnostics Gaining Access to Settings and DiagnosticsAdjusting the Setpoint Temperature Temperature DisplaySwitching the Display Between Fahrenheit and Celsius F5 Cabinet Temperature Correction calibration factor Settings and Diagnostics Menu Later SectionDefrost Termination Temperature F1 Defrost Interval F0Setpoint Temperature Differential F2 High Temperature Alarm Delay Time F3 Low Temperature Alarm Delay Time F4Temperature Display Scale F5 Alarm History F6Compressor Run Time F7 Operating ModesEnergy Saving Perimeter Frame HeaterContinuous III. Service Diagnosis Alarm Codes Alarm Signals Alarm Code ProblemAlarm Display Priority Error Code Priority DescriptionReset Options Alarm Details and CountermeasuresHigh Temperature Alarm E1 Possible CausesLow Temperature Alarm E2 Defrost Alarm E3 High Pressure Alarm E4Clogged Filter Alarm E7 Defrost Temperature Sensor Malfunction Alarm E8 Clogged Filter Sensor Malfunction Alarm E9 Control Board Error Alarms EA and ED Diagnosis Chart Problem Possible Cause RemedyProblem Possible Cause Remedy Problem Possible Cause Remedy Thermistor Check Refrigerant Recovery IV. Removal and Replacement of ComponentsService for Refrigerant Lines BrazingEvacuation and Recharge Removal and Replacement of Refrigeration Unit Removal and Replacement of CompressorRemoval and Replacement of Evaporator Page Page Defrost Thermistor Removal and Replacement of ThermistorsCabinet Thermistor Clogged Filter Thermistor sensorRemoval and Replacement of Door Gasket Removal and Replacement of Defrost HeaterRemoval and Replacement of Control Board Condenser Fan Motor Removal and Replacement of Fan MotorsDoor Re-Hinging and Drawer Conversion Evaporator Fan MotorCleaning and Maintenance Instructions CleaningShelves MaintenanceAir Filter Drawers115/60/1 A2. HUR40A-D, HWR40A-D auxiliary code Q6 and later HUF40A-D, HWF40A-D C1. HUR68A, HWR68A auxiliary code Q5 and earlier C2. HUR68A-D, HWR68A-D auxiliary code Q6 and later HUF68A-D, HWF68A-D HUR96A-D, HWR96A-D